Your Trusted Source for Industrial Electrical Components

170391

RCCB

Eaton | xEffect FRCmM Type AC and A residual current circuit breakers | 170391

RCCBProduct Type
25 AAmperage Rating

Additional Technical Details

View Full Specifications
Product Weight0.187 kg
Product Length/Depth76 mm
Product Height80 mm
Product Width35 mm

Standards & Approvals

  • RoHS conform
  • IEC/EN 61008 EN45545-2 IEC 61373

Typical Applications

Switchgear for industrial and advanced commercial applicationsxEffect - Switchgear for industrial and advanced commercial applications

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller series xEffect - FRCmM Type AC, A, U, R RCCB
Catalog Number170391
Model CodeFRCMM-25/2/003
EAN4015081668816
Product Length/Depth76 mm
Product Height80 mm
Product Width35 mm
Product Weight0.187 kg
CompliancesRoHS conform
CertificationsIEC/EN 61008 EN45545-2 IEC 61373
Product TypeRCCB
Amperage Rating25 A
ApplicationSwitchgear for industrial and advanced commercial applicationsxEffect - Switchgear for industrial and advanced commercial applications
Fault current rating30 mA
Impulse withstand current250 A (8/20 μs) surge-proof Partly surge-proof 250 A
Number of polesTwo-pole
Rated short-circuit strength10 kA with back-up fuse
Sensitivity typeAC current sensitive
Tripping timeNon-delayed
TypeFRCmMResidual current circuit breakersType AC
Additional information
FeaturesAdditional equipment possible Residual current circuit breaker
Fitted with:Interlocking device
Special featuresCurrent test marks as per inscriptionMaximum operating temperature is 55 °C: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C
Used withFRCmM Type AC Residual current circuit breakers
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Ambient operating temperature - max55 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent2 W
Heat dissipation capacity0 W
Heat dissipation per pole, current-dependent0 W
Rated operational current for specified heat dissipation (In)25 A
Static heat dissipation, non-current-dependent0 W
Electrical Characteristics
Admissible back-up fuse overload - max25 A gG/gL
Frequency rating50 Hz
Leakage current typeAC
Lifespan, electrical4000 operations
Pollution degree2
Rated fault current - max0.03 A
Rated fault current - min0.03 A
Rated impulse withstand voltage (Uimp)4 kV
Rated insulation voltage (Ui)440 V
Rated operational voltage (Ue) - max240 V
Rated residual making and breaking capacity500 A
Rated short-time withstand current (Icw)10 kA
Short-circuit rating63 A (max. admissible back-up fuse)
Surge current capacity0.25 kA
Test circuit range184 V AC - 250 V AC
Voltage rating (IEC/EN 60947-2)240 V AC
Mechanical & Physical
Built-in depth70.5 mm
Built-in width (number of units)35 mm (2 SU)
Busbar material thickness0.8 mm - 2 mm
Climatic proofing25-55 °C / 90-95% relative humidity according to IEC 60068-2
Connectable conductor cross section (multi-wired) - max16 mm²
Connectable conductor cross section (multi-wired) - min1.5 mm²
Connectable conductor cross section (solid-core) - max35 mm²
Connectable conductor cross section (solid-core) - min1.5 mm²
Contact position indicator colorRed / green
Degree of protectionIP20, IP40 with suitable enclosure IP20
Frame45 mm
Lifespan, mechanical20000 operations
Mounting MethodQuick attachment with 2 latch positions for DIN-rail IEC/EN 60715 DIN rail
Mounting positionAs required
Permitted storage and transport temperature - max60 °C
Permitted storage and transport temperature - min-35 °C
Status indicationWhite / blue
Terminal capacity (cable)M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal capacity (solid wire)1.5 mm² - 35 mm²
Terminal capacity (stranded cable)16 mm² (2x)
Terminal protectionFinger and hand touch safe, DGUV VS3, EN 50274
Terminals (top and bottom)Twin-purpose terminals
Tightening torque2 Nm - 2.4 Nm
Width in number of modular spacings2

Note: Specifications are taken from the official Eaton 170391 product data sheet.

Documents & Downloads

Official technical documentation for the 170391.

Typical Applications

Typical applications of the 170391.

Industrial Automation
Power Distribution
Machine Building
Energy Management
Process Industry
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment