Industrial Drive, Welding & New Energy Power Supply
LEM closed-loop and open-loop Hall effect current transducers for variable speed drives, servo motors, welding equipment, UPS systems, and new energy power conversion.
AHR-Series
High-performance open-loop current sensors
5 models
| Part Number | Primary Current | Power Supply | Bandwidth | Insulation Test Voltage | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| AHR 1000 B10 | 1000 A | 1) +20 ... 50 V DC | DC 20 … 6000 Hz | 5.8 kV | AHR-1000-B10.pdf | Request a Quote |
| AHR 1000 B420 | 1000 A | 1) +20 ... 50 V DC | DC 20 … 6000 Hz | 5.8 kV | AHR-1000-B420.pdf | Request a Quote |
| AHR 1000 B5 | 1000 A | 1) +20 ... 50 V DC | DC, 20 … 6000 Hz | 5.8 kV | AHR-1000-B5.pdf | Request a Quote |
| AHR 1500 B10 | 1500 A | 1) +20 ... 50 V DC | DC 20 … 6000 Hz | 5.8 kV | AHR-1500-B10.pdf | Request a Quote |
| AHR 1500 B420 | 1500 A | 1) +20 ... 50 V DC | DC 20 … 6000 Hz | 5.8 kV | AHR-1500-B420.pdf | Request a Quote |
AIP-Series
Open-loop current sensors for industrial automation
5 models
| Part Number | Max Measuring Range | Power Supply | Accuracy Class | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| AI-P1A | 5000 A | 24 V DC | 0.5 | 0.10 % | AI-P1A.pdf | Request a Quote |
| AI-PMUL | TH35-7.5 TH35-15 | 1.5 kV | Class 0.5 | Class Typ 0.5 [3] | AI-PMUL.pdf | Request a Quote |
AK-Series
Industrial open-loop current sensors
5 models
| Part Number | Power Supply | Mass | Storage Temperature | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| AK 200 B10 | Self Powered | 120 g | -20..+85 °C | 61326 | AK-200-B10.pdf | Request a Quote |
| AK 200 B420L | (Loop powered) 24 V DC | 120 g | 61326 | < 300 mS | AK-200-B420L.pdf | Request a Quote |
| AK 200 C10 | Self powered | ±1 % | 1 min 3 kV | 50-60 Hz | AK-200-C10.pdf | Request a Quote |
| AK 200 C420L | 24 V DC | 120 g | ±1 mm | 20-100 Hz | AK-200-C420L.pdf | Request a Quote |
| AK 5 B420L | (Loop powered) 24 V DC | 120 g | -20..+85 °C | 61326 | AK-5-B420L.pdf | Request a Quote |
AP-Series
High-performance open-loop current sensors
5 models
| Part Number | Linearity Error | Impulse withstand voltage 1.2/50 | Creepage distance | Power Supply | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| AP 100 B10 | ±0.5 % | µs 6.1 kV | 5.5 mm | 1 min 4.13 kV | AP-100-B10.pdf | Request a Quote |
| AP 100 B420L | < ±0.5 % | < ± 1 % of I | 30 .. 2000 Hz | (loop powered) +12 … 24 V DC | AP-100-B420L.pdf | Request a Quote |
| AP 200 B10 | ±0.5 % | µs 6.1 kV | 5.5 mm | 1 min 4.13 kV | AP-200-B10.pdf | Request a Quote |
| AP 200 B420L | < ±0.5 % | < ± 1 % of I | 30 .. 2000 Hz | (loop powered) +12 … 24 V DC | AP-200-B420L.pdf | Request a Quote |
| AP 400 B10 | ±0.5 % | µs 6.1 kV | 5.5 mm | 1 min 4.13 kV | AP-400-B10.pdf | Request a Quote |
ART-Series
Open-loop current sensors for industrial drives
5 models
| Part Number | Primary Current | Technology | Bandwidth | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| ART-B22-D125 | Any current (no saturation) | Rogowski | 373 kHz | Class 0.5 | ART-B22-D125.pdf | Request a Quote |
| ART-B22-D125/SP25 3m, SMA | Any current (no saturation) | Rogowski | 420 kHz | Class 0.5 | ART-B22-D125-SP25-3m,-SMA.pdf | Request a Quote |
| ART-B22-D175 | Any current (no saturation) | Rogowski | 350 kHz | Class 0.5 | ART-B22-D175.pdf | Request a Quote |
| ART-B22-D300/SP4 | Any current (no saturation) | Rogowski | 300 kHz | Class 0.5 | ART-B22-D300-SP4.pdf | Request a Quote |
| ART-B22-D70 | Any current (no saturation) | Rogowski | 420 kHz | Class 0.5 | ART-B22-D70.pdf | Request a Quote |
ARU-Series
Open-loop current sensors for renewable energy
5 models
| Part Number | Technology | Impulse withstand voltage 1.2/50 μs | m | Clearance | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| ARU-B100-D125 | closed loop | 12.8 kV | 1275 V | > 16 mm | ARU-B100-D125.pdf | Request a Quote |
| ARU-B100-D125/SP3 | closed loop | 12.8 kV | 1275 V | > 16 mm | ARU-B100-D125-SP3.pdf | Request a Quote |
| ARU-B100-D125/SP4 | closed loop | 12.8 kV | 1275 V | > 16 mm | ARU-B100-D125-SP4.pdf | Request a Quote |
| ARU-B100-D125/SP6 | closed loop | 12.8 kV | 1275 V | > 16 mm | ARU-B100-D125-SP6.pdf | Request a Quote |
| ARU-B100-D175 | closed loop | 12.8 kV | 1275 V | > 16 mm | ARU-B100-D175.pdf | Request a Quote |
AT-Series
Open-loop current sensors
5 models
| Part Number | Power Supply | Comparative Tracking Index | Overvoltage Category / Pollution Degree | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| AT 10 B10 | self-powered | 600 | Over voltage category CAT · Pollution degree PD2 | 50/60 Hz | AT-10-B10.pdf | Request a Quote |
| AT 10 B420L | (loop-powered) +15.2 … 30 V DC | 600 | Over voltage category CAT · Pollution degree PD2 | without prior notice | AT-10-B420L.pdf | Request a Quote |
| AT 10 B5 | self-powered | 600 | Over voltage category CAT · Pollution degree PD2 | 50/60 Hz | AT-10-B5.pdf | Request a Quote |
| AT 100 B10 | self-powered | 600 | Over voltage category CAT · Pollution degree PD2 | 50/60 Hz | AT-100-B10.pdf | Request a Quote |
| AT 100 B420L | (loop-powered) +15.2 … 30 V DC | 600 | Over voltage category CAT · Pollution degree PD2 | without prior notice | AT-100-B420L.pdf | Request a Quote |
ATO-Series
Open-loop current sensors
5 models
| Part Number | Linearity Error | Operating Temperature | Storage Temperature | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| ATO-10-B225-D10/SP3 ATO XDK | −0.1 ... 0.1 % of IPN | −10 ... 55 °C | −30 ... 90 °C | 1.5 kHz | ATO-10-B225-D10-SP3-ATO-XDK.pdf | Request a Quote |
| ATO-100-B333-D16 | ± 0.1 % | −10 … 25 °C | −30 … 90 °C | IEC 61869-1 ed1.0: 2007 | ATO-100-B333-D16.pdf | Request a Quote |
| ATO-125-B1I-D16 | ± 0.1 % | −20 … 70 °C | −40 … 85 °C | 500 kHz | ATO-125-B1I-D16.pdf | Request a Quote |
| ATO-125-B225-D16 | ± 0.1 % | −10 … 25 °C | −30 … 90 °C | IEC 61869-1 ed1.0: 2007 | ATO-125-B225-D16.pdf | Request a Quote |
| ATO-5-B420-D10/SP4 4m cable output | ± 0.5 % | −10 … 25 °C | −30 … 90 °C | 140 g | ATO-5-B420-D10-SP4-4m-cable-output.pdf | Request a Quote |
CAS-CASR
Closed-loop coreless current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| CAS 15-NP | 15 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CAS-15-NP.pdf | Request a Quote |
| CAS 25-NP | 25 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CAS-25-NP.pdf | Request a Quote |
| CAS 50-NP | 50 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CAS-50-NP.pdf | Request a Quote |
| CAS 6-NP | 6 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CAS-6-NP.pdf | Request a Quote |
| CASR 15-NP | 15 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CASR-15-NP.pdf | Request a Quote |
CKSR-Series
Automotive closed-loop current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| CKSR 15-NP | 15 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CKSR-15-NP.pdf | Request a Quote |
| CKSR 25-NP | 25 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CKSR-25-NP.pdf | Request a Quote |
| CKSR 50-NP | 50 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CKSR-50-NP.pdf | Request a Quote |
| CKSR 50-NP/SP1 | 50 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CKSR-50-NP-SP1.pdf | Request a Quote |
| CKSR 6-NP | 6 A | 4.75 ... 5.25 V | Closed loop (compensated) | 200 kHz | CKSR-6-NP.pdf | Request a Quote |
CTSR-Series
Closed-loop current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| CTSR 0.3-P | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 3.5 ... 500 kHz | CTSR-0.3-P.pdf | Request a Quote |
| CTSR 0.3-P/SP10 | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 3.5 ... 500 kHz | CTSR-0.3-P-SP10.pdf | Request a Quote |
| CTSR 0.3-TP/SP14 | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 3.5 ... 500 kHz | CTSR-0.3-TP-SP14.pdf | Request a Quote |
| CTSR 0.3-TP/SP4 | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 3.5 kHz | CTSR-0.3-TP-SP4.pdf | Request a Quote |
| CTSR 0.6-P | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 3.5 ... 500 kHz | CTSR-0.6-P.pdf | Request a Quote |
DHR-Series
High-accuracy open-loop current sensors
5 models
| Part Number | Power Supply | Comparative Tracking Index | Overvoltage Category / Pollution Degree | Primary Current | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| DHR 100 C10 | 2) +20 ... 50 V DC | 600 | Over voltage category CAT · Pollution degree PD2 | 7.2 mm | DHR-100-C10.pdf | Request a Quote |
| DHR 100 C420 | 2) +20 ... 50 V DC | 600 | Over voltage category CAT · Pollution degree PD2 | currents: DC, AC, pulsed... | DHR-100-C420.pdf | Request a Quote |
| DHR 1000 C10 | + 20 .. 50 V DC | DC 20..6000 Hz | < ± 1 % of I | 1000 A | DHR-1000-C10.pdf | Request a Quote |
| DHR 1000 C420 | + 20 .. 50 V DC | DC 20..6000 Hz | < ± 1 % of I | 1000 A | DHR-1000-C420.pdf | Request a Quote |
| DHR 200 C10 | 2) +20 ... 50 V DC | 600 | Over voltage category CAT · Pollution degree PD2 | 7.2 mm | DHR-200-C10.pdf | Request a Quote |
DK-Series
Compact open-loop current sensors
5 models
| Part Number | Power Supply | Bandwidth | Operating Temperature | Storage Temperature | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| DK 100 B10 | 20-45 V DC | DC Hz | (0-95%) RH) - 20 | - 20 .. + 85 °C | DK-100-B10.pdf | Request a Quote |
| DK 100 B420 | 20-45 V DC | DC Hz | (0-95% RH) - 20 . | - 20 .. + 85 °C | DK-100-B420.pdf | Request a Quote |
| DK 100 B420 U | 20-45 V DC | DC Hz | (0-95% RH) - 20 . | - 20 .. + 85 °C | DK-100-B420-U.pdf | Request a Quote |
| DK 100 B5 | 20-45 V DC | DC Hz | (0-95% RH) - 20 . | - 20 .. + 85 °C | DK-100-B5.pdf | Request a Quote |
| DK 100 C10 U | 20-45 V DC | DC Hz | (0-95% RH) - 20 . | - 20 .. + 85 °C | DK-100-C10-U.pdf | Request a Quote |
EM4T-Series
Current sensors
5 models
| Part Number | Max. Traction System Voltage | Supply Voltage | Accuracy Class | System Frequencies | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| EM4TII AC-MS DC-MS +XPS 110VDC, RS232 | 25 kV AC / 3 kV DC | 110 V DC | Class 0.5 R | DC / 16.7 / 50 / 60 Hz | EM4TII-AC-MS-DC-MS-+XPS-110VDC,-RS232.pdf | Request a Quote |
FRS-Series
Current sensors
5 models
| Part Number | Technology | Measurement | Storage Temperature | Mass | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| FRS 1000-S | Open Loop | 1000 A | 10 ... 28 V | 1000 kHz | FRS-1000-S.pdf | Request a Quote |
| FRS 1000-SBI | Open Loop | current: DC, AC, pulsed... | −40 ... +90 °C | 472 g | FRS-1000-SBI.pdf | Request a Quote |
| FRS 1500-SBI | Open Loop | current: DC, AC, pulsed... | −40 ... +90 °C | 472 g | FRS-1500-SBI.pdf | Request a Quote |
| FRS 2000-SBI | Open Loop | current: DC, AC, pulsed... | −40 ... +90 °C | 472 g | FRS-2000-SBI.pdf | Request a Quote |
| FRS 3000-S | Open Loop | 3000 A | 10 ... 28 V | 1000 kHz | FRS-3000-S.pdf | Request a Quote |
GO-Series
Current sensors
5 models
| Part Number | Primary Current | Technology | Linearity Error | Impulse Withstand Voltage | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| GO 10-SME | 10 ... 800 A | Open loop | −0.3 ... 0.3 % of IPN | 4 kV | GO-10-SME.pdf | Request a Quote |
| GO 10-SME Demoboard 2320 | 10 ... 800 A | Open loop | −0.3 ... 0.3 % of IPN | 4 kV | GO-10-SME-Demoboard-2320.pdf | Request a Quote |
| GO 10-SME/SP3 | 10 ... 800 A | Open loop | −0.3 ... 0.3 % of IPN | 4 kV | GO-10-SME-SP3.pdf | Request a Quote |
| GO 10-SMS | 10 A | Open loop | −0.3 ... 0.3 % of IPN | 7.6 kV | GO-10-SMS.pdf | Request a Quote |
| GO 10-SMS Demoboard 2325 | 10 A | Open loop | −0.3 ... 0.3 % of IPN | 7.6 kV | GO-10-SMS-Demoboard-2325.pdf | Request a Quote |
HAC-Series
Current sensors
5 models
| Part Number | Power Supply | Bandwidth | Storage Temperature | Mass | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAC 200-S | 1) ±15 V | DC ... 50 kHz | −15 ... +85 °C | 70 g | HAC-200-S.pdf | Request a Quote |
| HAC 300-S | 1) ±15 V | DC ... 50 kHz | −15 ... +85 °C | 70 g | HAC-300-S.pdf | Request a Quote |
| HAC 400-S | 1) ±15 V | DC ... 50 kHz | −15 ... +85 °C | 70 g | HAC-400-S.pdf | Request a Quote |
| HAC 600-S | 1) ±15 V | DC ... 50 kHz | −15 ... +85 °C | 70 g | HAC-600-S.pdf | Request a Quote |
| HAC 800-S | 1) ±15 V | DC ... 50 kHz | −15 ... +85 °C | 70 g | HAC-800-S.pdf | Request a Quote |
HAIS-Series
High-accuracy industrial sensors
5 models
| Part Number | Bandwidth | Linearity Error | Load impedance | Load resistance | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAIS 100-P | DC ... 50 kHz | ±0.5 % | ≥ 200 kΩ | ≥ 2 kΩ | HAIS-100-P.pdf | Request a Quote |
| HAIS 100-TP | DC ... 50 kHz | ±0.5 % | ≥ 200 kΩ | ≥ 2 kΩ | HAIS-100-TP.pdf | Request a Quote |
| HAIS 150-P | DC ... 50 kHz | ±0.5 % | ≥ 200 kΩ | ≥ 2 kΩ | HAIS-150-P.pdf | Request a Quote |
| HAIS 150-TP | DC ... 50 kHz | ±0.5 % | ≥ 200 kΩ | ≥ 2 kΩ | HAIS-150-TP.pdf | Request a Quote |
| HAIS 200-P | DC ... 50 kHz | ±0.5 % | ≥ 200 kΩ | ≥ 2 kΩ | HAIS-200-P.pdf | Request a Quote |
HAL-Series
Open-loop current sensors
5 models
| Part Number | Power Supply | Bandwidth | Linearity Error | Operating Temperature | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAL 100-S | ±15 V | DC .. 50 kHz | ±0.5 % | -25 .. +85 °C | HAL-100-S.pdf | Request a Quote |
| HAL 150-S | ±15 V | DC ... 50 kHz | ±0.5 % | ±1 % | HAL-150-S.pdf | Request a Quote |
| HAL 200-S | ±15 V | DC .. 50 kHz | ±0.5 % | -25 .. +85 °C | HAL-200-S.pdf | Request a Quote |
| HAL 300-S | ±15 V | DC .. 50 kHz | ±0.5 % | -25 .. +85 °C | HAL-300-S.pdf | Request a Quote |
| HAL 400-S | ±15 V | DC .. 50 kHz | ±0.5 % | -25 .. +85 °C | HAL-400-S.pdf | Request a Quote |
HAR-Series
High-accuracy current sensors
5 models
| Part Number | Power Supply | Technology | Bandwidth | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAR 1000-S | ±15 V | Open loop current transducer | DC … 10 kHz | ±0.5 % | HAR-1000-S.pdf | Request a Quote |
HAS-Series
Industrial Hall effect current sensors
5 models
| Part Number | Power Supply | Bandwidth | Linearity Error | Insulation Test Voltage | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAS 100-P | ±15 V | DC ... 50 kHz | ±1 % | 100 A | HAS-100-P.pdf | Request a Quote |
| HAS 100-S | ±15 V | DC ... 50 kHz | ±1 % | 3.6 kV | HAS-100-S.pdf | Request a Quote |
| HAS 200-P | ±15 V | DC ... 50 kHz | ±1 % | 200 A | HAS-200-P.pdf | Request a Quote |
| HAS 200-S | ±15 V | DC ... 50 kHz | ±1 % | 3.6 kV | HAS-200-S.pdf | Request a Quote |
| HAS 200-S/SP105 | ±15 V | DC ... 50 kHz | ±1 % | 3.6 kV | HAS-200-S-SP105.pdf | Request a Quote |
HASS-Series
High-accuracy sensors for new energy
5 models
| Part Number | Power Supply | Bandwidth | Total Error | Creepage Distance | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HASS 100-S | 2) 5 V | 5 DC ... 240 kHz | ±1 % | 6.9 mm | HASS-100-S.pdf | Request a Quote |
| HASS 200-S | 2) 5 V | 5 DC ... 240 kHz | ±1 % | 6.9 mm | HASS-200-S.pdf | Request a Quote |
| HASS 300-S | 2) 5 V | 5 DC ... 240 kHz | ±1 % | 6.9 mm | HASS-300-S.pdf | Request a Quote |
| HASS 400-S | 2) 5 V | 5 DC ... 240 kHz | ±1 % | 6.9 mm | HASS-400-S.pdf | Request a Quote |
| HASS 50-S | 2) 5 V | 5 DC ... 240 kHz | ±1 % | 6.9 mm | HASS-50-S.pdf | Request a Quote |
HAT-Series
Open-loop sensors for high-current
5 models
| Part Number | Power Supply | Bandwidth | Linearity Error | Primary Current | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAT 1000-S | ±15 V | DC ... 25 kHz | ±1 % | 1000 A | HAT-1000-S.pdf | Request a Quote |
| HAT 1200-S | ±15 V | DC ... 25 kHz | ±1 % | 1200 A | HAT-1200-S.pdf | Request a Quote |
| HAT 1500-S | ±15 V | DC ... 25 kHz | ±1 % | 1500 A | HAT-1500-S.pdf | Request a Quote |
| HAT 200-S | ±15 V | DC ... 25 kHz | ±1 % | 200 A | HAT-200-S.pdf | Request a Quote |
| HAT 400-S | ±15 V | DC ... 25 kHz | ±1 % | 400 A | HAT-400-S.pdf | Request a Quote |
HAX-Series
Current sensors
5 models
| Part Number | Bandwidth | Linearity Error | Insulation Test Voltage | Operating Temperature | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAX 1000-S | DC … 25 kHz | ±1 % | 5 kV | −40 ... +85 °C | HAX-1000-S.pdf | Request a Quote |
| HAX 1200-S | DC ... 25 kHz | ±1 % | 5.0 kV | −40 ... +85 °C | HAX-1200-S.pdf | Request a Quote |
| HAX 1500-S | DC … 25 kHz | ±1 % | 5 kV | −40 ... +85 °C | HAX-1500-S.pdf | Request a Quote |
| HAX 2000-S | DC … 25 kHz | ±1 % | 5 kV | −40 ... +85 °C | HAX-2000-S.pdf | Request a Quote |
| HAX 2000-S/SP19 | DC ... 25 kHz | ±1 % | 5.0 kV | −40 ... +105 °C | HAX-2000-S-SP19.pdf | Request a Quote |
HAZ-Series
Industrial current sensors
5 models
| Part Number | Power Supply | Measurement | Impulse Withstand Voltage | Rated Insulation Voltage | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HAZ 10000-SB | ±15 V | DC ... 3 kHz | ±0.5 % | 17 kV | HAZ-10000-SB.pdf | Request a Quote |
| HAZ 10000-SBI | ±15 V | currents: DC, AC, pulsed... | 32 kV | 8000 V · 9000 V | HAZ-10000-SBI.pdf | Request a Quote |
| HAZ 10000-SBI/SP1 | ±15 V | currents: DC, AC, pulsed... | 32 kV | 8000 V · 9000 V | HAZ-10000-SBI-SP1.pdf | Request a Quote |
| HAZ 12000-SB | ±15 V | 12000 A | DC ... 3 kHz | ±0.5 % | HAZ-12000-SB.pdf | Request a Quote |
| HAZ 12000-SBI | ±15 V | currents: DC, AC, pulsed... | 32 kV | 8000 V · 9000 V | HAZ-12000-SBI.pdf | Request a Quote |
HLSR-Series
Low-cost open-loop sensors
5 models
| Part Number | Technology | Primary Current | Power Supply | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HLSR 10-P | Open loop | 10 A | 4.5 ... 5.5 V | −0.5 ... 0.5 % of IPN | HLSR-10-P.pdf | Request a Quote |
| HLSR 10-P/SP33 | Open loop | 10 A | 3.135 ... 3.465 V | −0.5 ... 0.5 % of IPN | HLSR-10-P-SP33.pdf | Request a Quote |
| HLSR 10-SM | Open loop | 10 A | 4.5 ... 5.5 V | −0.5 ... 0.5 % of IPN | HLSR-10-SM.pdf | Request a Quote |
| HLSR 10-SM/SP33 | Open loop | 10 A | 3.135 ... 3.465 V | −0.5 ... 0.5 % of IPN | HLSR-10-SM-SP33.pdf | Request a Quote |
| HLSR 100-P/SP10 | Open loop | 100 A | 4.5 ... 5.5 V | −0.5 ... 0.5 % of IPN | HLSR-100-P-SP10.pdf | Request a Quote |
HMS-Series
Medium-size open-loop sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HMSR 10-SMS | 10 A | 4.5 ... 5.5 V | open loop | 300 kHz | HMSR-10-SMS.pdf | Request a Quote |
| HMSR 15-SMS | 15 A | 4.5 ... 5.5 V | open loop | 300 kHz | HMSR-15-SMS.pdf | Request a Quote |
| HMSR 20-SMS | 20 A | 4.5 ... 5.5 V | open loop | 300 kHz | HMSR-20-SMS.pdf | Request a Quote |
| HMSR 30-SMS | 30 A | 4.5 ... 5.5 V | open loop | 300 kHz | HMSR-30-SMS.pdf | Request a Quote |
| HMSR 6-SMS | 6 A | 4.5 ... 5.5 V | open loop | 300 kHz | HMSR-6-SMS.pdf | Request a Quote |
HO-Series
Current sensors
5 models
| Part Number | Primary Current | Bandwidth | Power Supply | Technology | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HO 10-P | 10 A | 250 kHz | 4.5 ... 5.5 V | ±1.35 % of IPN | HO-10-P.pdf | Request a Quote |
| HO 10-P/SP33 | 10 A | 250 kHz | 3.14 ... 3.46 V | ±0.5 % of IPN | HO-10-P-SP33.pdf | Request a Quote |
| HO 100-P-0100 | 100 A | 100 kHz | −1 ... 1 % of IPN | Open loop | HO-100-P-0100.pdf | Request a Quote |
| HO 100-S-0100 | 100 A | 100 µs | 4.5 ... 5.5 V | Open loop | HO-100-S-0100.pdf | Request a Quote |
| HO 100-S/SP33-1106 | 100 A | 100 kHz | −1 ... 1 % of IPN | Open loop | HO-100-S-SP33-1106.pdf | Request a Quote |
HOP-HTR
Open-loop high-temperature sensors
5 models
| Part Number | Technology | Bandwidth | Linearity Error | Power Supply | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HOP 1000-SB | Open loop | DC ... 10 kHz | ±1 % | 15 V | HOP-1000-SB.pdf | Request a Quote |
| HOP 1500-SB | Open loop | DC ... 10 kHz | ±1 % | 15 V | HOP-1500-SB.pdf | Request a Quote |
| HOP 200-SB | Open loop | DC ... 8 kHz | ≤ ±1 % | ±12 ... 15 V D S | HOP-200-SB.pdf | Request a Quote |
| HOP 2000-SB | Open loop | DC ... 10 kHz | ±1 % | 15 V | HOP-2000-SB.pdf | Request a Quote |
| HOP 2000-SB/SP1 | Open loop | DC .. 4 kHz | ≤ ±1 % | 15 V | HOP-2000-SB-SP1.pdf | Request a Quote |
HSN-Series
Industrial sensors
5 models
| Part Number | Power Supply | Technology | Bandwidth | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HSNBV 800-R01 | 4.75 .. 5.25 V | Open Loop Transducer | 1100 Hz | ± 0.5 % | HSNBV-800-R01.pdf | Request a Quote |
| HSNBV 800-R02 | 4.75 .. 5.25 V | Open Loop Transducer | 1100 Hz | ± 0.5 % | HSNBV-800-R02.pdf | Request a Quote |
| HSNBV-D05 | 4.75 .. 5.25 V | Open Loop Transducer | 1100 Hz | ± 0.5 % | HSNBV-D05.pdf | Request a Quote |
| HSNBV-D06 | 4.75 .. 5.25 V | Open Loop Transducer | 1100 Hz | ± 0.5 % | HSNBV-D06.pdf | Request a Quote |
| HSNBV-D09 | 4.75 .. 5.25 V | Open Loop Transducer | 1100 Hz | ± 0.5 % | HSNBV-D09.pdf | Request a Quote |
HSTDR-Series
High-stability current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HSTDR 1200-000 | ± 1200 A | 4.75 .. 5.25 V | Open Loop Transducer | 40 kHz | HSTDR-1200-000.pdf | Request a Quote |
HSW-Series
Current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HSW S01 | ± 200 A | 4.5 .. 5.5 V | Open Loop Transducer | 70 Hz | HSW-S01.pdf | Request a Quote |
HTA-Series
High-temperature open-loop sensors
5 models
| Part Number | Bandwidth | Linearity Error | Power Supply | Technology | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HTA 100-S | DC ... 50 kHz | ±0.5 % | ±15 V | Open loop transducer | HTA-100-S.pdf | Request a Quote |
| HTA 1000-S | DC ... 50 kHz | ±0.5 % | ±15 V | Open loop transducer | HTA-1000-S.pdf | Request a Quote |
| HTA 1000-S/SP9 | DC ... 50 kHz | ±0.5 % | ±15 V | < ±10 mV | HTA-1000-S-SP9.pdf | Request a Quote |
| HTA 200-S | DC ... 50 kHz | ±0.5 % | ±15 V | Open loop transducer | HTA-200-S.pdf | Request a Quote |
| HTA 250-S/SP3 | DC ... 25 kHz | ±0.5 % | ±1 % of IPN | < ±10 mV | HTA-250-S-SP3.pdf | Request a Quote |
HTB-Series
High-temperature sensors
5 models
| Part Number | Bandwidth | Linearity Error | Operating Temperature | Case Material | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HTB 100-P | DC … 50 kHz | ±1 % | −40 ... +80 °C | Insulating plastic case recognized according to UL 94-V0. | HTB-100-P.pdf | Request a Quote |
| HTB 100-P/SP5 | DC … 50 kHz | ±1 % | −25 ... +85 °C | Insulating plastic case recognized according to UL 94-V0. | HTB-100-P-SP5.pdf | Request a Quote |
| HTB 100-TP | DC … 50 kHz | ±1 % | −40 ... +80 °C | Insulating plastic case recognized according to UL 94-V0. | HTB-100-TP.pdf | Request a Quote |
| HTB 150-P | DC … 50 kHz | ±1 % | −20 .. +80 °C | 15 V | HTB-150-P.pdf | Request a Quote |
| HTB 200-P | DC … 50 kHz | ±1 % | −40 ... +80 °C | Insulating plastic case recognized according to UL 94-V0. | HTB-200-P.pdf | Request a Quote |
HTC-Series
Industrial sensors
5 models
| Part Number | Power Supply | Technology | Linearity Error | COUT R Output internal resistance | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HTC 1000-S/SP4 | 15 V | Open loop current transducer | ±1 % | < 100 Ω | HTC-1000-S-SP4.pdf | Request a Quote |
| HTC 2000-S/SP4 | 15 V | Open loop current transducer | ±1 % | < 100 Ω | HTC-2000-S-SP4.pdf | Request a Quote |
| HTC 3000-S/SP4 | 15 V | Open loop current transducer | ±1 % | < 100 Ω | HTC-3000-S-SP4.pdf | Request a Quote |
HTFS
Current sensors
5 models
| Part Number | Bandwidth | Linearity Error | Output internal resistance | Load resistance | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HTFS 200-P | DC ... 240 kHz | ±0.5 % | < 5 Ω | ≥ 2 kΩ | HTFS-200-P.pdf | Request a Quote |
| HTFS 200-P/SP2 | DC .. 240 kHz | ±0.5 % | <5 Ω | 4.7 nF | HTFS-200-P-SP2.pdf | Request a Quote |
| HTFS 400-P | DC ... 240 kHz | ±0.5 % | < 5 Ω | ≥ 2 kΩ | HTFS-400-P.pdf | Request a Quote |
| HTFS 400-P/SP2 | DC .. 240 kHz | ±0.5 % | <5 Ω | 4.7 nF | HTFS-400-P-SP2.pdf | Request a Quote |
| HTFS 600-P | DC ... 240 kHz | ±0.5 % | < 5 Ω | ≥ 2 kΩ | HTFS-600-P.pdf | Request a Quote |
HX-P-Series
High-performance sensors
5 models
| Part Number | Power Supply | Linearity Error | Delay time to 90 % of the output value for I step | Electrical Offset Voltage | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HX 02-P | ±15 V | ±1 % | ≤ 3 µs | < ±40 mV | HX-02-P.pdf | Request a Quote |
| HX 03-P | ±15 V | ±1 % | ≤ 3 µs | < ±40 mV | HX-03-P.pdf | Request a Quote |
| HX 03-P/SP2 | 15 V | ±1 % | ≤ 3 µs | 50 kHz | HX-03-P-SP2.pdf | Request a Quote |
| HX 04-P | ±15 V | ±1 % | ≤ 3 µs | < ±40 mV | HX-04-P.pdf | Request a Quote |
| HX 05-NP | ±15 V | ±1 % | ≤ 3 µs | 50 kHz | HX-05-NP.pdf | Request a Quote |
HXS-Series
High-precision closed-loop current sensors
5 models
| Part Number | Bandwidth | Linearity Error | Mass | Insulation Test Voltage | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| HXS 10-NP/SP3 | DC ... 50 kHz | ±0.5 % | 10 g | −40 ... +85 °C | HXS-10-NP-SP3.pdf | Request a Quote |
| HXS 20-NP | DC ... 50 kHz | ±0.5 % | 10 g | 3.5 kV | HXS-20-NP.pdf | Request a Quote |
| HXS 20-NP/SP30 | DC ... 50 kHz | ±0.5 % | 5 V | 3.5 kV | HXS-20-NP-SP30.pdf | Request a Quote |
| HXS 50-NP | DC ... 50 kHz | ±0.5 % | 10 g | 3.5 kV | HXS-50-NP.pdf | Request a Quote |
LA-205-305--S---T
Current sensors
5 models
| Part Number | Power Supply | Technology | Bandwidth | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LA 205-S | ± 12 .. 15 V | Closed loop (compensated) | DC .. 100 kHz | < 0.1 % | LA-205-S.pdf | Request a Quote |
| LA 205-S/SP1 | ± 12 .. 15 V | Closed loop (compensated) | DC .. 100 kHz | < 0.1 % | LA-205-S-SP1.pdf | Request a Quote |
| LA 205-S/SP21 | ± 15 .. 24 V | Closed loop (compensated) | DC .. 100 kHz | < 0.1 % | LA-205-S-SP21.pdf | Request a Quote |
| LA 205-S/SP33 | ± 15 V | Closed loop (compensated) | DC .. 100 kHz | < 0.1 % | LA-205-S-SP33.pdf | Request a Quote |
| LA 205-S/SP6 | ± 12 .. 15 V | Closed loop (compensated) | DC .. 100 kHz | < 0.1 % | LA-205-S-SP6.pdf | Request a Quote |
LA-306-S-Series
Current sensors
5 models
| Part Number | Power Supply | Technology | Bandwidth | Linearity Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LA 130-P | ±12 … 15 V | Closed loop (compensated) | DC … 150 kHz | < 0.1 % | LA-130-P.pdf | Request a Quote |
| LA 130-P/SP1 | ±12 ... 15 V | Closed loop (compensated) | DC ... 150 kHz | < 0.1 % | LA-130-P-SP1.pdf | Request a Quote |
| LA 150-P | ±12 ... 15 V | Closed loop (compensated) | DC ... 150 kHz | < 0.1 % | LA-150-P.pdf | Request a Quote |
| LA 150-P/SP1 | ±12 ... 15 V | Closed loop (compensated) | DC ... 150 kHz | < 0.1 % | LA-150-P-SP1.pdf | Request a Quote |
| LA 150-TP | ±12 ... 15 V | Closed loop (compensated) | DC ... 150 kHz | < 0.1 % | LA-150-TP.pdf | Request a Quote |
LA25-200-Series
Closed-loop compensated current sensors
5 models
| Part Number | Power Supply | Technology | Bandwidth | Primary Current | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LA 100-P | ±12 … 15 V | Closed loop (compensated) | DC … 200 kHz | 100 A | LA-100-P.pdf | Request a Quote |
| LA 100-P/SP13 | ±12 ... 15 V | Closed loop (compensated) | DC ... 200 kHz | 100 A | LA-100-P-SP13.pdf | Request a Quote |
| LA 100-TP | ±12 ... 15 V | Closed loop (compensated) | DC ... 200 kHz | 100 A | LA-100-TP.pdf | Request a Quote |
| LA 125-P | ±12 … 15 V | Closed loop (compensated) | (−1 dB) DC … 100 kHz | 125 A | LA-125-P.pdf | Request a Quote |
| LA 125-P/SP1 | ±12 ... 15 V | Closed loop | (−1 dB) DC ... 100 kHz | 0 ... ±200 A | LA-125-P-SP1.pdf | Request a Quote |
LAC-Series
Closed-loop current sensors
5 models
| Part Number | Power Supply | Technology | Bandwidth | Total Error | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LAC 300-S | ±15 V | Closed loop (compensated) | DC ... 50 kHz | ±1.0 % | LAC-300-S.pdf | Request a Quote |
| LAC 300-S/SP1 | ±15 V | Closed loop (compensated) | DC ... 50 kHz | ±0.9 % | LAC-300-S-SP1.pdf | Request a Quote |
| LAC 300-S/SP10 Cable output (600 mm) | ±24 V | Closed loop (compensated) | DC ... 50 kHz | ±1.4 % | LAC-300-S-SP10-Cable-output-(600-mm).pdf | Request a Quote |
| LAC 300-S/SP2 | ±15 V | Closed loop (compensated) | DC ... 50 kHz | ±1.0 % | LAC-300-S-SP2.pdf | Request a Quote |
| LAC 300-S/SP3 | ±15 V | Closed loop (compensated) | DC ... 50 kHz | ±1.1 % | LAC-300-S-SP3.pdf | Request a Quote |
LAH-Series
High-accuracy closed-loop sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LAH 100-P | 100 A | ±12 ... 15 V | Closed loop (compensated) | DC ... 200 kHz | LAH-100-P.pdf | Request a Quote |
| LAH 125-P | 125 A | ±12 ... 15 V | Closed loop (compensated) | @ I DC ... 100 kHz | LAH-125-P.pdf | Request a Quote |
| LAH 25-NP | 25 A | ±12 … 15 V | Closed loop (compensated) | DC … 200 kHz | LAH-25-NP.pdf | Request a Quote |
| LAH 50-P | 50 A | ±12 … 15 V | Closed loop (compensated) | DC ... 200 kHz | LAH-50-P.pdf | Request a Quote |
| LAH 50-P/SP1 | 50 A | ±12 … 15 V | Closed loop (compensated) | DC ... 200 kHz | LAH-50-P-SP1.pdf | Request a Quote |
LAS-Series
Closed-loop sensors
5 models
| Part Number | Power Supply | Bandwidth | Operating Temperature | Storage Temperature | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LAS 100-TP | 5 V | DC … 100 kHz | −40 … +85 °C | −40 … +100 °C | LAS-100-TP.pdf | Request a Quote |
| LAS 50-TP | 5 V | DC … 100 kHz | −40 … +85 °C | −40 … +100 °C | LAS-50-TP.pdf | Request a Quote |
LDSR-Series
Low-cost closed-loop sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LDSR 0.3-NP | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 2 kHz | LDSR-0.3-NP.pdf | Request a Quote |
| LDSR 0.3-TP/SP1 | 300 mA | 4.75 ... 5.25 V | Closed loop (compensated) | 2 kHz | LDSR-0.3-TP-SP1.pdf | Request a Quote |
LES-Series
Closed-loop sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LES 15-NP | 15 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LES-15-NP.pdf | Request a Quote |
| LES 25-NP | 25 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LES-25-NP.pdf | Request a Quote |
| LES 50-NP | 50 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LES-50-NP.pdf | Request a Quote |
| LES 6-NP | 6 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LES-6-NP.pdf | Request a Quote |
| LESR 15-NP | 15 ... 22 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LESR-15-NP.pdf | Request a Quote |
LF-Series
Closed-loop current sensors
5 models
| Part Number | Technology | Bandwidth | Power Supply | Primary Current | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LF 1005-S | Closed loop (compensated) | DC .. 150 kHz | ± 15 .. 24 V | 1000 A | LF-1005-S.pdf | Request a Quote |
| LF 1005-S/SP14 | Closed loop (compensated) | DC ... 150 kHz | ±24 V | 1000 A | LF-1005-S-SP14.pdf | Request a Quote |
| LF 1005-S/SP22 | Closed loop (compensated) | DC ... 150 kHz | 15 ... ±24 V | 1000 A | LF-1005-S-SP22.pdf | Request a Quote |
| LF 1005-S/SP33 | Closed loop (compensated) | DC ... 150 kHz | ±24 V | 1000 A | LF-1005-S-SP33.pdf | Request a Quote |
| LF 1010-S | Closed loop (compensated) | 200 kHz | ±14.25 .. ±25.2 V | 1000 A | LF-1010-S.pdf | Request a Quote |
LKSR-Series
Low-accuracy sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LKSR 15-NP | 15 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LKSR-15-NP.pdf | Request a Quote |
| LKSR 25-NP | 25 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LKSR-25-NP.pdf | Request a Quote |
| LKSR 50-NP | 50 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LKSR-50-NP.pdf | Request a Quote |
| LKSR 6-NP | 6 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LKSR-6-NP.pdf | Request a Quote |
LPSR-Series
Low-accuracy sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LPSR 15-NP | 15 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LPSR-15-NP.pdf | Request a Quote |
| LPSR 25-NP | 25 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LPSR-25-NP.pdf | Request a Quote |
| LPSR 50-NP | 50 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LPSR-50-NP.pdf | Request a Quote |
| LPSR 6-NP | 6 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LPSR-6-NP.pdf | Request a Quote |
LT-Series
Closed-loop sensors
5 models
| Part Number | Power Supply | Primary Current | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LT 100-S/SP30 | ±0.5 % | < 0.1 % | 225 | −40 … +70 °C | LT-100-S-SP30.pdf | Request a Quote |
| LT 10000-S | ±48 … 60 V | 10000 A | Closed loop (compensated) | DC … 100 kHz | LT-10000-S.pdf | Request a Quote |
| LT 1005-S | ± 15 .. 24 V | 1000 A | Closed loop (compensated) | DC .. 150 kHz | LT-1005-S.pdf | Request a Quote |
| LT 1005-S/SP1 | ± 24 V | 1000 A | Closed loop (compensated) | DC .. 150 kHz | LT-1005-S-SP1.pdf | Request a Quote |
| LT 1005-S/SP19 | ± 15 .. 24 V | 1000 A | Closed loop (compensated) | DC .. 150 kHz | LT-1005-S-SP19.pdf | Request a Quote |
LWSR-Series
Current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LWSR 250-P | 250 A | 4.75 ... 5.25 V | Closed loop | 200 kHz | LWSR-250-P.pdf | Request a Quote |
LXS-Series
Current sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LXS 15-NPS | 15 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LXS-15-NPS.pdf | Request a Quote |
| LXS 25-NPS | 25 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LXS-25-NPS.pdf | Request a Quote |
| LXS 6-NPS | 6 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LXS-6-NPS.pdf | Request a Quote |
| LXSR 15-NPS | 15 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LXSR-15-NPS.pdf | Request a Quote |
| LXSR 25-NPS | 25 A | 4.75 ... 5.25 V | Closed loop | 300 ... 1 kHz | LXSR-25-NPS.pdf | Request a Quote |
LZSR-Series
Low-accuracy sensors
5 models
| Part Number | Primary Current | Power Supply | Technology | Bandwidth | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| LZSR 100-P | 100 A | 4.75 ... 5.25 V | Closed loop | 200 kHz | LZSR-100-P.pdf | Request a Quote |
| LZSR 100-TP | 100 A | 4.75 ... 5.25 V | Closed loop | 200 kHz | LZSR-100-TP.pdf | Request a Quote |
| LZSR 150-P | 150 A | 4.75 ... 5.25 V | Closed loop | 200 kHz | LZSR-150-P.pdf | Request a Quote |
| LZSR 150-P/SP1 | 150 A | 4.75 ... 5.25 V | Closed loop | 200 kHz | LZSR-150-P-SP1.pdf | Request a Quote |
| LZSR 150-TP | 150 A | 4.75 ... 5.25 V | Closed loop | 200 kHz | LZSR-150-TP.pdf | Request a Quote |
PCM-Series
Pulse current sensors
Open-loop current sensors for industrial automation
5 models
| Part Number | Power Supply | Technology | Bandwidth | Operating Temperature | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| PCM 10-P | +25 % continuous) +2 | Closed loop (compensated) | DC … 1 kHz | (continuous) −40 | PCM-10-P.pdf | Request a Quote |
| PCM 10-P/SP1 | +25 % continuous) +2 | Closed loop (compensated) | DC … 1 kHz | −40 … +85 °C | PCM-10-P-SP1.pdf | Request a Quote |
| PCM 20-P | +24 V | Closed loop (compensated) | DC … 1 kHz | (continuous) −25 | PCM-20-P.pdf | Request a Quote |
| PCM 30-P | +24 V | Closed loop (compensated) | DC … 1 kHz | (continuous) −25 … | PCM-30-P.pdf | Request a Quote |
| PCM 30-P/SP1 | +24 V | Closed loop (compensated) | DC ... 1 kHz | −25 ... +55 °C | PCM-30-P-SP1.pdf | Request a Quote |
RA-Series
Industrial current sensors
5 models
| Part Number | Application Domain | Resistance of secondary winding | Inductance of secondary windings | Number of secondary turns | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| RA 1005-S | Railway (fixed installations and onboard) | = 85 °C | 5.9 mH | 1480 | RA-1005-S.pdf | Request a Quote |
| RA 2000-S/SP1 | 20 ... 3000 Hz | 20 Hz ... 100 Hz 10 Hz ... 3000 Hz | −25 ... 70 °C | −40 ... 85 °C | RA-2000-S-SP1.pdf | Request a Quote |
TT-Series
Industrial current sensors
5 models
| Part Number | Application Domain | Overvoltage Category / Pollution Degree | Linearity Error | Storage Temperature | Datasheet | Inquiry |
|---|---|---|---|---|---|---|
| TT 100-SD | Energy and Automation, isEtrniberugtyed measurement systems, Automation. domain Energy and Automation | Over voltage category OV · Pollution degree PD2 | 0.1 % | −30 … +90 °C | TT-100-SD.pdf | Request a Quote |
| TT 50-SD | i sEtrnibeurgteyd measurement systems, Automation. domain and Automation | Over voltage category OV · Pollution degree PD2 | ±1 % | 600 | TT-50-SD.pdf | Request a Quote |
| ART-B22-D70 | — | — | — | — | Request a Quote |