Your Trusted Source for Industrial Electrical Components

DS7-340SX032N0-N

DS7 Soft starter

Eaton | DS7 soft starter | DS7-340SX032N0-N

DS7 Soft starterProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.4 kg
Product Length/Depth118 mm
Product Height150 mm
Product Width45 mm

Standards & Approvals

  • CE Marked
  • UL 508
  • CSA Std. C22.2 No. 0-M91
  • CSA Std. C22.2 No. 14-05
  • IEC 60947-4-2
  • EN 60947-4-2 C-Tick CSA22.2-14

Typical Applications

1-phase motors: No 3-phase motors: Yes Soft starting of three-phase asynchronous motors

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton DS7 Soft starter
Catalog Number134914
Model CodeDS7-340SX032N0-N
EAN4015081316991
Product Length/Depth118 mm
Product Height150 mm
Product Width45 mm
Product Weight0.4 kg
CompliancesCE Marked
CertificationsUL 508 CSA Std. C22.2 No. 0-M91 CSA Std. C22.2 No. 14-05 IEC 60947-4-2 EN 60947-4-2 C-Tick CSA22.2-14 UL File No.: E251034 CSA File No.: 2511305 CSA-C22.2 No 14-05 UL UkrSEPRO GB 14048.6 CE CSA-C22.2 No 0-M91 CSA IEC/EN 60947-4-2 CSA Class No.: 321106
ClassOther
Connection to SmartWire-DTNo
Degree of protectionNEMA 1 IP20
Frame sizeFS2
Mains voltage - max480 V
Mains voltage - min200 V
Overvoltage categoryII
Pollution degree2
Radio interference classClass B (EN 55011)
Suitable forBranch circuits, (UL/CSA)
TypeSoft starter for three-phase loads
Voltage typeAC/DC
Environmental Conditions
Mounting positionVertical
Shock resistance8 g, 11 ms, Mechanical
Vibration resistance2M2 to EN 60721-3-2
AltitudeAbove 1000 m with 1 % derating per 100 m Max. 2000 m
Ambient operating temperature - max40 °C
Ambient storage temperature - max60 °C
Ambient operating temperature - min-5 °C
Ambient storage temperature - min-25 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-3
Control circuit
Current consumption50 mA, Control circuit, Regulator supply 1.6 mA, Control circuit, Digital inputs, External 24 V
Drop-out time350 ms, Control circuit, Digital Inputs, DC operated
Drop-out voltageAC operated: 0 - 3 V, AC operated 0 - 3 V, DC operated
Pick-up time250 ms at AC 250 ms at DC
Pick-up voltage17.3 - 27 V DC 17.3 - 27 V AC
Rated control supply voltage (Us) at AC, 50 Hz - max24 V
Rated control supply voltage (Us) at AC, 50 Hz - min24 V
Rated control supply voltage (Us) at AC, 60 Hz - max24 V
Rated control supply voltage (Us) at AC, 60 Hz - min24 V
Rated control supply voltage (Us) at DC - max24 V
Rated control supply voltage (Us) at DC - min24 V
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid1.5 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0 W
Rated operational current for specified heat dissipation (In)32 A
Static heat dissipation, non-current-dependent Pvs1.5 W
Main conducting paths
Overload cycleAC-53a: 3 - 5: 75 - 10
Rated operational current (Ie) at AC-5332 A
Rated operational voltage (Ue) - max480 V
Rated operational voltage (Ue) - min230 V
Short-circuit protection rating3 x 170M1366, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths PKM0-32 (+ CL-PKZ0), Type “1” coordination, Main conducting paths
Supply frequency50/60 Hz, fLN, Main circuit
Voltage rating - max480 V
Additional Specifications
Fitted with:Internal bypass Internal bypass contacts
FunctionsPotential isolation between power and control sections Suppression of DC components for motors Soft start function Single direction Suppression of closing transients Min. ramp time 1 s - fast switching (semiconductor contactor)
Application1-phase motors: No 3-phase motors: Yes Soft starting of three-phase asynchronous motors
Delay time0 - 30 s, Soft start function, Ramp times
Ramp/run-up time1 - 30 s
Start voltageMin. 30 %, Soft start function, Start voltage = turn-off voltage Max. 100 %, Soft start function, Start voltage = turn-off voltage
Number of outputs2 Relay Outputs (TOR, Ready)
Output voltage250 V AC (relay outputs)
ProtectionFinger and back-of-hand proof, Protection against direct contact
Rated control voltage (Uc)24 V AC 24 V DC 24 V DC (-15 %/+10 %) 24 V AC (-15 %/+10 %)
Rated operational current (Ie) at AC-111 A
Assigned motor power at 200/208 V, 60 Hz, 3-phase10 HP
Assigned motor power at 220/230 V, 60 Hz, 3-phase10 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase25 HP
Rated operational power at 220/230 V, 50 Hz7.5 kW
Rated operational power at 400 V, 50 Hz15 kW
Screwdriver sizePZ2, 1 x 6 mm, Terminal screw, Standard screwdriver 0.6 x 3.5 mm, Terminal screws, Control circuit cables
Terminal capacity (flexible with ferrule)2 x (0.5 - 0.75) mm², Control circuit cables 2 x (0.75 - 10) mm², Main cables 1 x (0.5 - 1.5) mm², Control circuit cables 1 x (0.75 - 16) mm², Main cables
Terminal capacity (solid)2 x (0.75 - 10) mm², Main cables 1 x (0.5 - 2.5) mm², Control circuit cables 2 x (0.5 - 1.0) mm², Control circuit cables 1 x (0.75 - 16) mm², Main cables
Terminal capacity (solid/stranded AWG)1 x (21 - 14), Control circuit cables 2 x (21 - 18), Control circuit cables 18 - 6, Main cables
Terminal capacity (stranded)1 x (0.5 - 1.5) mm², Control circuit cables 1 x 16 mm², Main cables 2 x (0.5 - 1.0) mm², Control circuit cables
Tightening torque3.2 Nm 1.2 Nm, Screw terminals, Control circuit cables

Note: Specifications are taken from the official Eaton DS7-340SX032N0-N product data sheet.

Documents & Downloads

Official technical documentation for the DS7-340SX032N0-N.

Typical Applications

Typical applications of the DS7-340SX032N0-N.

Industrial Automation
Power Distribution
Machine Building
Energy Management
Process Industry
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment