Your Trusted Source for Industrial Electrical Components

EASY-E4-DC-12TC1

Control relays easyE4

Eaton | All Eaton Products | 197213

Power supply: 24 V DC (-15 %/+ 20 %) Po…Voltage
Control relays easyE4Product Type

Additional Technical Details

View Full Specifications
Product Weight0.2 kg
Product Length/Depth58 mm
Product Height90 mm
Product Width72 mm
Degree Of ProtectionIP20
Mounting MethodScrew fixing using fixing brackets ZB4-101-GF1 (accessories) Top-hat rail fixing (accordi…

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Industrial Automation, Power Distribution, Machine Building and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series EASY Control relay
Catalog Number197213
EAN4015081939466
Model CodeEASY-E4-DC-12TC1
Display typeMonochrome
Product categoryControl relays easyE4
TypeeasyE4 base device
Voltage typeDC
Connection typeScrew terminal Ethernet: RJ45 plug, 8-pole
Cable typeEthernet: CAT5
Electrical Characteristics
Duty factor100 %
Frequency counterCable length: ≤ 20 m (shielded) Counter frequency: ≤ 5 kHz Number: 4 (I1, I2, I3, I4) Pulse pause ratio: 1:1 Pulse shape: Square
Insulation resistanceAccording to EN IEC 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-207
Overvoltage categoryPower supply + Inputs + Extension interface: II Power supply outputs + Outputs: II
Residual current0.1 mA (on signal "1" per channel)
Switching frequencyDepending on the suppressor circuit (Inductive load to EN 60947-5-1, With external suppressor circuit, Max. switching frequency, max. duty factor) Dependent on the cycle time of the basic device
Shock resistance15 g, Mechanical, acc. to IEC/EN61131-2, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance8.4 - 150 Hz, 1 g constant acceleration 5 - 8.4 Hz, 3.5 mm constant amplitude According to IEC/EN 61131-2
Burst impulse2 kV, I/O port 2 kV, Power supply port 1 kV, communication port According to IEC/EN 61131-2
Radio interference classClass B (EN 61000-6-3)
Voltage dips10 ms
Power consumption2 W
Rated operational voltagePower supply: 24 V DC (-15 %/+ 20 %) Power supply transistor outputs: 24 V DC (-15 %/+ 20 %) Inputs: shall be identical to the power supply voltage
Supply current24/44 mA, Normally⁄max., On 1 signal, Transistor outputs 18/32 mA, Normally⁄max., On 0 signal, Transistor outputs
Supply voltage at DC - min20.4 VDC
Supply voltage at DC - max28.8 VDC
Short-circuit current6.8 A, Transistor outputs
Short-circuit protection≥ 1A (T), Fuse, Power supply Yes, electronic (Q1 - Q4), Transistor outputs
Short-circuit tripping current0.7 ≤ Ie ≤ 1.7 per output, For Ra ≤ 10 mΩ, Depending on number of active channels and their load, Transistor outputs
Input current1.8 mA (I5 - I8, at 24 V DC,at signal 1) 3.3 mA (I1 - I4, at 24 V DC,at signal 1) < 1 mA (Analog inputs)
Input voltageCondition 0: ≤ 5 V DC (Digital inputs, 24 V DC) Condition 1: ≥ 15 V DC (Digital inputs, 24 V DC)
Output voltageU = Uₑ - 1 V (signal 1 at Iₑ = 0.5 A, transistor outputs) Max. 1.0 V (at status 0 per channel, transistor outputs)
Utilization factor1 / group, with ext. suppressor circuit 0.25 / group, w/o ext. suppressor circuit, T0.95 = 15ms/R = 48Ω/L = 0.24H 0.25 / group, w/o ext. suppressor circuit, DC-13/T0.95 = 72ms/R = 48Ω/L = 1.15 H Inductive load to EN 60947-5-1
Equipment heat dissipation, current-dependent Pvid2 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0 W
Static heat dissipation, non-current-dependent Pvs2 W
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.11 Short-circuit ratingIs the panel builder's responsibility.
Mechanical & Physical
Product Length/Depth58 mm
Product Height90 mm
Product Width72 mm
Product Weight0.2 kg
Fitted with:Keypad Display Real time clock Timer Transistor output
Degree of protectionIP20
Mounting methodScrew fixing using fixing brackets ZB4-101-GF1 (accessories) Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Front build in possible Wall mounting/direct mounting Rail mounting possible
Height of fall (IEC/EN 60068-2-32) - max0.3 m
Mounting positionVertical Horizontal
Terminal capacity0.2 - 4 mm² (AWG 22 - 12), solid 0.2 - 2.5 mm², flexible with ferrule 0.2 - 2.5 mm², flexible without ferrule
Screwdriver size3.5 x 0.6 mm, Terminal screw
Tightening torque0.6 Nm, Screw terminals
Cable lengthDigital inputs (DC): ≤ 100 m (unshielded) Digital outputs: ≤ 100 m (unshielded) Analog inputs: ≤ 30 m (shielded)
Protection against polarity reversalFor transistor outputs (Caution: A short circuit will result if 0 V/earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles) Yes, for supply voltage
10.3 Degree of protection of assembliesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Environmental & Compliance
CompliancesEaton supports the product until its end of life
CertificationsUL File No.: E205091 CE UL hazardous location class I UL hazardous location group A (acetylene) UL hazardous location group D (propane) UL hazardous location group C (ethylene) UL hazardous location division 2 UL hazardous location group B (hydrogen) cULus Ordinary Location DNV TAA00002HT cULus Hazard Location UL File No.: E523283 EN 61131-2 IEC 61131-2 EN IEC 61000-6-3 IEC 61000-6-3 EN IEC 61010-2-201 IEC 61010-2-201 UL 61010-1 UL 61010-2-201 CSA C22.2 No. 61010-1 CSA C22.2 No. 61010-2-201 UL 121201 CSA C22.2 No. 213
Display temperature - min0 °C
Display temperature - max55 °C
Pollution degree2
Ambient operating temperature - min-25 °C
Ambient operating temperature - max55 °C
Ambient storage temperature - min-40 °C
Ambient storage temperature - max70 °C
Relative humidity5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Additional Specifications
Catalog NotesAccuracy of the real-time clock depending on ambient air temperature - fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible
FeaturesNetworkable (Ethernet) Expandable Display indication of 6 lines x 16 characters
IndicationLCD-display used as status indication of digital I/Os
ProtocolModbus TCP
Residual ripplePower supply: ≤ 5 % Power supply transistor outputs: 5 %
Resolution12 Bit (value 0 - 4095, Analog inputs)
SoftwareEASYSOFT-SWLIC/easySoft
Used witheasyE4
Drop and topple50 mm Drop height, Drop to IEC/EN 60068-2-31
Air pressure795 - 1080 hPa (operation)
Environmental conditionsCondensation: prevent with appropriate measures Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Air discharge8 kV
Contact discharge6 kV
Electromagnetic fields10 V/m at 0.08 - 1.0 GHz (according to IEC/EN 61131-2) 3 V/m at 1.0 - 6 GHz (according to IEC/EN 61131-2)
Immunity to line-conducted interference10 V (according to IEC/EN 61131-2)
Surge rating0.5 kV, Line-to-Line, Power supply port 1 kV, Line-to-Earth, Power supply port 1 kV, Line-to-Earth, I/O port 1 kV, Line-to-Earth, communication port According to IEC/EN 61131-2
Data transfer rate10/100 MBit/s
Accuracy± 2 %, (I5, I6, I7, I8) ± 0.12 V, of actual value, within a single device (Analog Inputs) ± 3 %, of actual value, two easy devices (Analog Inputs) ± 2 s/day, Real-time clock to inputs (± 0.2 h⁄Year) ± 1 %, Repetition accuracy of timing relays (of values)
ConversionsEach CPU cycle for Analog inputs
Delay timeDigital inputs (24 V DC): 20 ms, from 0 to 1, Debounce ON Digital inputs (24 V DC): 0.015 ms typ., from 0 to 1, Debounce OFF Digital inputs (24 V DC): 20 ms, from 1 to 0, Debounce ON Digital inputs (24 V DC): 0.015 ms typ., from 1 to 0, Debounce OFF
Incremental counterPulse pause ratio: 1:1 Pulse shape: Square Value range: -2147483648 to +2147483647 Number of counter inputs: 2 (I1 + I2, I3 + I4) Signal offset: 90° Counter frequency: ≤ 5 kHz Cable length: ≤ 20 m (shielded)
InputVoltage (DC)
Input impedanceAnalog: 13.3 kΩ
Number of inputs (analog)0 4
Number of inputs (digital)8 4
Number of outputs (analog)0
Number of outputs (digital)4
Output4 Transistor Outputs max. 2 A total current Parallel connection of group 1 (Q1 to Q4)
Rapid counter inputsPulse pause ratio: 1:1 Counter frequency: ≤ 10 kHz Cable length: ≤ 20 m (shielded) Value range: -2147483648 to +2147483647 Pulse shape: Square Number of rapid counter inputs: 4 (I1, I2, I3, I4)
Signal range0 - 10 V DC, Analog inputs
Potential isolationPOW+Inputs+Extension interface vs. POW outputs+Outputs: yes POW+Inputs+Extension interface vs. Ethernet+Functional Earth: yes Power supply outputs + Outputs against Ethernet + Functional Earth: yes
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Note: Specifications are taken from the official Eaton EASY-E4-DC-12TC1 datasheet.

Documents & Downloads

Official technical documentation for the EASY-E4-DC-12TC1.

Typical Applications

Typical applications of the EASY-E4-DC-12TC1.

Industrial Automation
Power Distribution
Machine Building
Energy Management
Process Industry
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment