Your Trusted Source for Industrial Electrical Components

EMS2-DO-T-3-SWD

Electronic motor starter

Eaton | All Eaton Products | 192383

3 AAmperage
500 V AC 42 - 550 VVoltage
1.1 kWRated Power
Electronic motor starterProduct Type

Additional Technical Details

View Full Specifications
Product Weight0.297 kg
Product Length/Depth114.5 mm
Product Height99 mm
Product Width22.5 mm
Degree Of ProtectionIP20 NEMA Other
Mounting MethodTop-hat rail fixing (according to IEC/EN 60715, 35 mm) Rail mounting possible

Standards & Approvals

  • Eaton global quality standards

Typical Applications

Industrial Automation, Power Distribution, Machine Building and more.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller® series EMS2 DOL starter
Catalog Number192383
EAN4015081930807
Model CodeEMS2-DO-T-3-SWD
Product categoryElectronic motor starter
TypeDOL starter (complete device)
Voltage typeDC
Electrical Characteristics
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid2.5 W
Heat dissipation capacity Pdiss0 W
Heat dissipation detailsIf necessary, Allow for derating
Heat dissipation per pole, current-dependent Pvid0 W
Rated operational current for specified heat dissipation (In)3 A
Static heat dissipation, non-current-dependent Pvs2 W
Inrush current120 mA (draw)
Rated control supply current Is60 mA
Rated control supply voltage19.2 - 30 V DC
Rated control supply voltage (Us) at DC - max24 V
Rated control supply voltage (Us) at DC - min24 V
Rated operational current (Ie)3 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V3 A
Rated operational current (Ie) at AC-513 A
Rated operational current (Ie) at AC-53A - max3 A
Rated operational power at AC-3, 220/230 V, 50 Hz0.55 kW
Rated operational power at AC-3, 380/400 V, 50 Hz1.1 kW
Rated operational power at AC-53A, 380/400 V, 50 Hz1.1 kW
Rated operational voltage500 V AC 42 - 550 V
Radio interference classClass A (EN 61000-6-3, emitted interference, radiated) EN 55011
ClassCLASS 10
Overload release current setting - max3 A
Overload release current setting - min0.18 A
Mechanical & Physical
Product Length/Depth114.5 mm
Product Height99 mm
Product Width22.5 mm
Product Weight0.297 kg
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Connection to SmartWire-DTYes
Degree of protectionIP20 NEMA Other
Mounting methodTop-hat rail fixing (according to IEC/EN 60715, 35 mm) Rail mounting possible
Mounting positionMotor feeder at bottom Vertical
Terminal capacity0.2 - 2.5 mm², Main cables, Push-in terminals
Terminal capacity (AWG)24 - 14, Push-in terminals
Environmental & Compliance
CertificationsUL508 IEC/EN 60947-4-2 UL File No.: E338590 UL Category Control No.: NLDX, NLDX7 UL 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE marking UL listed Certified by UL for use in Canada UL report applies to both US and Canada
Ambient operating temperature - max55 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-5 °C
Ambient storage temperature - min40 °C
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Additional Specifications
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
Switching level-3 - 9.6 V DC, Switching level "Low", Actuating circuit (ON, L, R) < 5 V DC, Switching level "confirm Off", Actuating circuit (ON, L, R) 19.2 - 30 V DC, Switching level "High", Actuating circuit (ON, L, R)
FunctionsDOL starting For connecting to SmartWire-DT for expanded diagnostics Temperature compensated overload protection Motor protection Automatic reset Display of Device Type Manual reset Display of Motor current in % Display of Operating direction feedback Operating the motor starter Display of Operational readiness Display of Overload prewarning Display of Set short-circuit release value Display of Thermal motor image in % Display of Trip indications (overload, phase failure, etc.)
ModelDirect starter
ProtocolOther bus systems
Residual ripple≤ 5 % (input voltage)

Note: Specifications are taken from the official Eaton EMS2-DO-T-3-SWD datasheet.

Documents & Downloads

Official technical documentation for the EMS2-DO-T-3-SWD.

Typical Applications

Typical applications of the EMS2-DO-T-3-SWD.

Industrial Automation
Power Distribution
Machine Building
Energy Management
Process Industry
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment