Your Trusted Source for Industrial Electrical Components

NZM2-4-XFIA

NZM Earth leakage relay

Eaton | Digital NZM Moulded Case Circuit Breaker | NZM2-4-XFIA

NZM Earth leakage relayProduct Type

Additional Technical Details

View Full Specifications
Product Weight2.03 kg
Product Length/Depth132 mm
Product Height103 mm
Product Width140 mm

Standards & Approvals

  • IEC
  • RoHS conform
  • IEC/EN 60947-2
  • IEC/EN 60947-2 annex B

Typical Applications

In three- and single-phase systems

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller series NZM Earth leakage relay
Catalog Number292346
Model CodeNZM2-4-XFIA
EAN4015082923464
Product Length/Depth132 mm
Product Height103 mm
Product Width140 mm
Product Weight2.03 kg
CompliancesIEC
RoHS conform
CertificationsIEC/EN 60947-2
IEC/EN 60947-2 annex B
ApplicationIn three- and single-phase systems
FeaturesSealable, setting buttons
Frame96 mm
NZM2
Number of polesFour-pole
Special featuresCore-balance principle with AC/DC sensitivity (in range 0 - 100 kHz)
For 4 pole NZM2-4 circuit-breakers and N2-4 switch-disconnectors
Internal power supply Us = 50 - 400 V
TypeEarth-fault releases
Used withNZM2-4
N2-4
Four-pole
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Ambient operating temperature - max70 °C
Ambient operating temperature - min-25 °C
Electrical Characteristics
Current rating - max250 A
Current rating - min15 A
Fault current detection rangeWith AC voltage: 0 - 100 kHz
With pulsed DC voltage: 50 Hz
Frequency rating50 Hz
Power on-delay time - max100 ms
Power on-delay time - min100 ms
Rated control supply voltage (Us) at AC, 50 Hz - max400 V
Rated control supply voltage (Us) at AC, 50 Hz - min50 V
Rated control supply voltage (Us) at AC, 60 Hz - max400 V
Rated control supply voltage (Us) at AC, 60 Hz - min50 V
Rated control supply voltage (Us) at DC - min0 V
Rated fault current - max1 A
Rated fault current - min0.3 A
Rated operating voltage (Ue) - max400 V
Sensitivity typeSensitive to AC/DC (type B)
Voltage rating50 - 400 V AC (independent of mains voltage)
Voltage rating at DC50 V DC (dependent on mains voltage)
Mechanical & Physical
Degree of protectionIP20 (operating component area)
Lifespan, mechanical≧ 2000 operations
Mounting MethodBottom
Mounting positionVertical and 90° in all directions
Shock resistance20 g (half-sinusoidal shock 20 ms)
Special featuresCore-balance principle with AC/DC sensitivity (in range 0 - 100 kHz)
For 4 pole NZM2-4 circuit-breakers and N2-4 switch-disconnectors
Internal power supply Us = 50 - 400 V
Additional Specifications
FunctionsDelay adjustable
Terminal capacity (solid/flexible conductor)As NZM2 standard connection with ferrules
As NZM2 standard terminal without ferrules

Note: Specifications are taken from the official Eaton NZM2-4-XFIA product data sheet.

Documents & Downloads

Official technical documentation for the NZM2-4-XFIA.

Typical Applications

Typical applications of the NZM2-4-XFIA.

Industrial Automation
Power Distribution
Machine Building
Energy Management
Process Industry
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment