NZMB2-A125

NZM molded case circuit breaker thermo-magnetic

Eaton | Digital NZM Moulded Case Circuit Breaker | NZMB2-A125

NZM molded case circuit breaker thermo-magneticProduct Type
125 AAmperage Rating

Additional Technical Details

View Full Specifications
Product Weight2.36 kg
Product Length/Depth149 mm
Product Height184 mm
Product Width105 mm

Standards & Approvals

  • RoHS conform
  • IEC/EN 60947

Typical Applications

Use in unearthed supply systems at 440 V

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller series NZM molded case circuit breaker thermo-magnetic
Catalog Number259087
Model CodeNZMB2-A125
EAN4015082590871
Product Length/Depth149 mm
Product Height184 mm
Product Width105 mm
Product Weight2.36 kg
CompliancesRoHS conform
CertificationsIEC/EN 60947
Amperage Rating125 A
ApplicationUse in unearthed supply systems at 440 V
FeaturesProtection unit Motor drive optional
Number of polesThree-pole
Special featuresMaximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn) Rated current = rated uninterrupted current: 125 A
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Ambient operating temperature - max70 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Ambient storage temperature - min40 °C
Equipment heat dissipation, current-dependent27.61 W
Electrical Characteristics
Amperage Rating125 A
Direction of incoming supplyAs required
Electrical connection type of main circuitScrew connection
Handle typeRocker lever
Instantaneous current setting (Ii) - max1250 A
Instantaneous current setting (Ii) - min750 A
Isolation300 V AC (between the auxiliary contacts) 500 V AC (between auxiliary contacts and main contacts)
Lifespan, electrical10000 operations at 400 V AC-1 6500 operations at 415 V AC-3 10000 operations at 415 V AC-1
Number of operations per hour - max120
Overload current setting (Ir) - max125 A
Overload current setting (Ir) - min100 A
Overvoltage categoryIII
Pollution degree3
Rated impulse withstand voltage (Uimp) at auxiliary contacts6000 V
Rated impulse withstand voltage (Uimp) at main contacts8000 V
Rated insulation voltage (Ui)690 V AC
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz30 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz25 kA
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz18.5 kA
Rated short-circuit making capacity Icm at 240 V, 50/60 Hz63 kA
Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz53 kA
Rated short-circuit making capacity Icm at 440 V, 50/60 Hz53 kA
Short-circuit release non-delayed setting - max1250 A
Short-circuit release non-delayed setting - min750 A
Short-circuit total breaktime< 10 ms
Utilization categoryA (IEC/EN 60947-2)
Voltage rating440 V - 440 V
Mechanical & Physical
Climatic proofingDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Degree of protectionIP20 (basic degree of protection, in the operating controls area) IP20
Degree of protection (IP), front sideIP40 (with insulating surround) IP66 (with door coupling rotary handle)
Degree of protection (terminations)IP10 (tunnel terminal) IP00 (terminations, phase isolator and strip terminal)
Lifespan, mechanical20000 operations
Mounting MethodBuilt-in device fixed built-in technique DIN rail (top hat rail) mounting optional Fixed
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Position of connection for main current circuitFront side
Protection against direct contactFinger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Shock resistance20 g (half-sinusoidal shock 20 ms)
Special featuresMaximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn) Rated current = rated uninterrupted current: 125 A
Terminal Capacities
Standard terminalsScrew terminal
Terminal capacity (aluminum solid conductor/cable)10 mm² - 16 mm² (1x) direct at switch rear-side connection 10 mm² - 16 mm² (2x) direct at switch rear-side connection 16 mm² (1x) at tunnel terminal
Terminal capacity (aluminum stranded conductor/cable)25 mm² - 50 mm² (1x) direct at switch rear-side connection 25 mm² - 50 mm² (2x) direct at switch rear-side connection 25 mm² - 185 mm² (1x) at tunnel terminal
Terminal capacity (control cable)0.75 mm² - 1.5 mm² (2x) 0.75 mm² - 2.5 mm² (1x)
Terminal capacity (copper busbar)Min. 16 mm x 5 mm direct at switch rear-side connection M8 at rear-side screw connection Max. 20 mm x 5 mm direct at switch rear-side connection
Terminal capacity (copper solid conductor/cable)4 mm² - 16 mm² (2x) at box terminal 4 mm² - 16 mm² (2x) direct at switch rear-side connection 4 mm² - 16 mm² (1x) at box terminal 4 mm² - 16 mm² (1x) direct at switch rear-side connection 16 mm² (1x) at tunnel terminal
Terminal capacity (copper stranded conductor/cable)25 mm² - 185 mm² (1x) direct at switch rear-side connection 25 mm² - 70 mm² (2x) direct at switch rear-side connection 25 mm² - 185 mm² (1x) at box terminal 25 mm² - 185 mm² (1x) at 1-hole tunnel terminal 25 mm² - 70 mm² (2x) at box terminal
Terminal capacity (copper strip)Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched) Min. 2 segments of 9 mm x 0.8 mm at box terminal Max. 10 segments of 16 mm x 0.8 mm at box terminal Min. 2 segments of 16 mm x 0.8 mm at rear-side connection (punched)

Note: Specifications are taken from the official Eaton NZMB2-A125 product data sheet.

Documents & Downloads

Official technical documentation for the NZMB2-A125.

Typical Applications

Typical applications of the NZMB2-A125.

Power Distribution
Motor Protection
Switchgear Assemblies
Industrial Panels
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment