Residual current circuit breakerProduct Type
25 AAmperage Rating

Additional Technical Details

View Full Specifications
Product Weight0.32 kg
Product Length/Depth76 mm
Product Height80 mm
Product Width70 mm

Standards & Approvals

  • RoHS conform

Typical Applications

Switchgear for export to North America (UL-listed)

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
Product NameEaton Moeller series xEffect - FRCmM-NA RCCB
Catalog Number167107
Model CodeFRCMM-25/4/003-G/A-NA
EAN4015081636075
Product Length/Depth76 mm
Product Height80 mm
Product Width70 mm
Product Weight0.32 kg
CompliancesRoHS conform
CertificationsUL 1053; IEC 61008; EN 61008; ÖVE E 8601; EN45545-2; IEC 61373
Catalog NotesAdditionally protects against special forms of residual pulsating DC which have not been smoothed.
Amperage Rating25 A
ApplicationSwitchgear for export to North America (UL-listed)
Fault current rating30 mA
Impulse withstand current3 kA (8/20 μs) surge-proof
Number of polesFour-pole
Rated short-circuit strength10 kA with back-up fuse; 5 kA (UL, as per CSA)
Sensitivity typePulse-current sensitive
Tripping time10 ms delay at 50 Hz; Short time-delayed; 8 ms delay at 60 Hz
TypeCurrent test marks as per inscription; Maximum operating temperature is 55 °C: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C; The maximum operating current of back-up fuse must not exceed the residual current circuit breaker's rated operational current
Additional information
FeaturesAdditional equipment possible; Residual current circuit breaker
Fitted with:Interlocking device
FunctionsShort-time delayed tripping
Special featuresFRCmM-NA; Residual current circuit breakers; Type G/A (ÖVE E 8601)
Used withResidual current circuit breakers; Type G/A (ÖVE E 8601); FRCmM-NA
Standards & Design Verification
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent3.1 W
Heat dissipation per pole, current-dependent0.775 W
Rated operational current for specified heat dissipation (In)25 A
Electrical Characteristics
Admissible back-up fuse overload - max25 A gG/gL
Frequency rating50 Hz / 60 Hz
Leakage current typeA
Lifespan, electrical4000 operations
Overvoltage tested - max530 V
Pick-up current22 mA
Pollution degree2
Rated fault current - max0.03 A
Rated fault current - min0.03 A
Rated impulse withstand voltage (Uimp)4 kV
Rated insulation voltage (Ui)440 V
Rated operational voltage (Ue) - max480 V
Rated residual making and breaking capacity500 A
Rated short-time withstand current (Icw)10 kA
Short-circuit ratingMax. admissible back-up fuse: 63 A gG/gL, 70 A class J fuse (UL)
Surge current capacity3 kA
Test circuit range184 V AC - 440 V AC, 196 V AC - 305 V AC (UL)
Voltage rating (IEC/EN 60947-2)240 V AC / 415 V AC
Voltage rating (UL)480Y/277 V, 60 Hz
Mechanical & Physical
Ambient humdity range5 - 95 %
Built-in depth70.5 mm
Built-in width (number of units)70 mm (4 SU)
Climatic proofing25-55 °C / 90-95% relative humidity according to IEC 60068-2
Connectable conductor cross section (multi-wired) - max16 mm²
Connectable conductor cross section (multi-wired) - min1.5 mm²
Connectable conductor cross section (solid-core) - max35 mm²
Connectable conductor cross section (solid-core) - min1.5 mm²
Contact position indicator colorRed / green
Degree of protectionIP20; IP20, IP40 with suitable enclosure
Frame45 mm
Lifespan, mechanical10000 operations
Mounting MethodQuick attachment with 2 latch positions for DIN-rail IEC/EN 60715; DIN rail
Mounting positionAs required
Permitted storage and transport temperature - max60 °C
Permitted storage and transport temperature - min-35 °C
Status indicationWhite / blue
Terminal capacity (cable)M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal capacity (solid wire)1.5 mm² - 35 mm²
Terminal capacity (stranded cable)16 mm² (2x)
Terminal protectionFinger and hand touch safe, DGUV VS3, EN 50274
Terminals (top and bottom)Lift terminals
Width in number of modular spacings4

Note: Specifications are taken from the official Eaton FRCMM-25/4/003-G/A-NA product data sheet.

Documents & Downloads

Official technical documentation for the FRCMM-25/4/003-G/A-NA.

Typical Applications

Typical applications of the FRCMM-25/4/003-G/A-NA.

Industrial Automation
Power Distribution
Machine Building
Energy Management
Process Industry
12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment