Your Trusted Source for Industrial Electrical Components

AI-PMUL

Configurable Rogowski coil signal conditioner

LEM | AI-Series

TH35-7.5 TH35-15Mounting on DIN rail (IEC 60715)
1.5 kVRMS voltage for AC insulation test, 50 Hz, 1 min (Ud)
V0Flammability according to UL94
+10...+32 V24 V DC Supply voltage (UCDC)
max. 100 mACurrent consumption (IC)

Additional Technical Details

View Full Specifications
Operating Temperature Range−25...+70 °C. • E
Ambient Operating Temperature (TA)−25...+70 °C. • E
Ambient storage temperature (TAst)−40...+85 °C
Relative humidity (non-condensing) (RH)95 %
Altitude above sea level2000 m
General dimensional tolerance±1 mm

Standards & Approvals

Typical Applications

UNVERIFIED

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The AI-PMUL is a None current transducer from LEM.

The accuracy class is Typ 0.5 [3]. Typical applications include UNVERIFIED.

Key characteristics from the official datasheet: operating temperature −25...+70 °C. • E.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAI
Product ReferenceAI-PMUL
Measurement—
Mounting—
Application Domain—
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−25...+70 °C. • E
Ambient storage temperature (TAst)−40...+85 °C
Relative humidity (non-condensing) (RH)95 %
Altitude above sea level2000 m
General dimensional tolerance±1 mm
Dimensions100 × 78 × 15 mm³
Mounting on DIN rail (IEC 60715)TH35-7.5 TH35-15
Insulation Coordination
RMS voltage for AC insulation test, 50 Hz, 1 min (Ud)1.5 kV
Flammability according to UL94V0
Power Supply
24 V DC Supply voltage (UCDC)+10...+32 V
Current consumption (IC)max. 100 mA
Input Signal
Rogowski coil sensitivity selectionWith push buttons
Selection indicationbi-color LED
Rogowski coil sensitivities22.5, 70, 80, 85, 100, 120 mV/kA
Typical input impedance10 kΩ
Rated frequency (ƒr)50…60 Hz
Frequency bandwidth (at 3 dB) (BW)10…1500 Hz
Current measurement range selectionWith push buttons
Current measurement range100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A
Overcurrent measurement range120 %
Short time withstand current on primary for 3 s [1]130 kA
Output Signal
0...20 mA true RMS current output mode (Iout)Min 0 / Max 24 mA
4...20 mA true RMS current output mode (Iout)Min 4 / Max 23.2 mA
0...5 V true RMS voltage output mode (Uout)Min 0 / Max 6 V
0...10 V true RMS voltage output mode (Uout)Min 0 / Max 12 V
225 mV instantaneous voltage output mode (Uout)Min 0 / Max 270 mV
333 mV instantaneous voltage output mode (Uout)Min 0 / Max 400 mV
Load resistance (all current output mode) (RL)Min 0 / Max 500 Ω
Load resistance (all voltage output mode) (RL)Min 1 kΩ
Temperature drift (all output mode) (TCS)Max 150 ppm/K
Phase displacement @ 50 Hz or 60 Hz [2] (Δφ)Max 0.5°
Accuracy classTyp 0.5 [3]
Linearity error (ɛL)Max 0.1 %

Note: Specifications are taken from the official AI-PMUL datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AI-PMUL are shown below.

AI-PMUL outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AI-PMUL datasheet
Outline Dimensions & Mechanical Data
General dimensional tolerance±1 mm

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AI-PMUL.

UNVERIFIED

Characteristic Curves

The characteristic curves of the AI-PMUL from the official datasheet are shown below.

AI-PMUL characteristic curves
Characteristic curves — source: LEM AI-PMUL datasheet
Accuracy & Dynamic Characteristics
Rogowski coil sensitivity selectionWith push buttons
Frequency bandwidth (at 3 dB) (BW)10…1500 Hz
Phase displacement @ 50 Hz or 60 Hz [2] (Δφ)Max 0.5°
Accuracy classTyp 0.5 [3]
Linearity error (ɛL)Max 0.1 %
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)Min 0 / Max 500 Ω
Rated Frequency (fr)50…60 Hz
Accuracy ClassTyp 0.5 [3]

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment