ARU-B100-D250/SP4

closed loop

LEM | ARU-Series | closed loop | IEC 61010-1 | Busbar Mount

closed loopTechnology
12.8 kVImpulse withstand voltage 1.2/50 μs (UNi)
1275 V(q Partial discharge RMS test voltage < 10 pC) m (Ut)
> 16 mmClearance (pri. - sec.) (dCI)
V0Case material

Additional Technical Details

View Full Specifications
Operating Temperature Range−40 ... 80 °C
Isolation Test Voltage7.4 kV
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud7.4 kV
Impulse Withstand Voltage (1.2/50 µs) UNi12.8 kV
Comparative Tracking Index (CTI)600
RMS voltage for AC insulation test, 50 Hz, 1 min (Ud)7.4 kV

Standards & Approvals

  • IEC 61010-1:2010/AMD1: 2016; IEC 61010-2-32:
  • IEC 61869-10:
  • UL: 61010-1: 2012.

Typical Applications

Outdoor substations, Distribution transformer monitoring, Medium voltage isolated cable distribution, Underground substations, Pole-mounted transformers, Low voltage overhead lines, Distributions system equipment. Standards, IEC 61010-1:2010/AMD1: 2016; IEC 61010-2-32: 2012, IEC 61869-10: 2017, UL: 61010-1: 2012. Application Domains, Industrial, Smart Grid. Page 1/11 Route du Nant-d’Avril, 152 www.lem.com

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The ARU-B100-D250/SP4 is a closed loop (compensated) current transducer from LEM.

Since it cannot saturate, very high and short-circuit currents are measured without degradation. Typical applications include Outdoor substations, Distribution transformer monitoring, Medium voltage isolated cable distribution and Underground substations.

Key characteristics from the official datasheet: operating temperature −40 ... 80 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesARU
Product ReferenceARU-B100-D250/SP4
Measurement—
MountingBusbar Mount
Application DomainIndustrial, Smart Grid
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud7.4 kV
Impulse Withstand Voltage (1.2/50 µs) UNi12.8 kV
Comparative Tracking Index (CTI)600
RMS voltage for AC insulation test, 50 Hz, 1 min (Ud)7.4 kV
Impulse withstand voltage 1.2/50 μs (UNi)12.8 kV
(q Partial discharge RMS test voltage < 10 pC) m (Ut)1275 V
Clearance (pri. - sec.) (dCI)> 16 mm
Creepage distance (pri. - sec.) (dCp)> 16 mm
Case materialV0
Application example - indoor use RMS voltage line-to-neutral1000 V
Application example - outdoor use RMS voltage line-to-neutral600 V
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 80 °C
Ambient Storage Temperature (TA st)−40 ... 80 °C
Mass (m)236 g
Relative humidity (non-condensing) (RH)Min 0 / Max 90 %
Altitude above sea levelMax 2000 m
Mass 125 ⌀ (m)Typ 236 g
Mass 175 ⌀ (m)Typ 247 g
Mass 250 ⌀ (m)Typ 277 g
Mass 300 ⌀ (m)Typ 297 g
Standards & Certifications
IEC 61010-12010/AMD1: 2016; IEC 61010-2-32:
IEC 61869-10Compliance
UL: 61010-1: 2012.
Absolute Maximum Ratings
Maximum secondary voltage (RMS) (USmax)30 V
Absolute Maximum Ratings
Maximum primary conductor temperature (TBmax)105 °C
Electrical Data
Rated short-time thermal current (Ith)Typ 20 kA
Rated transformation ratio (kr)Typ 10 kA/V
Rated frequency (fr)Typ 50/60 Hz
Mutual inductance (M)Typ 321.9 nH
M Temperature coefficient of (TCM)Typ ±30 ppm/k
Coil inductance (LS)Typ 1080 µH
Coil resistance (RS)Typ 113 Ω
Ratio error (centered) (ε)Min −0.5 / Max 0.5 %
Ratio error (all positions) (ε)Min −1 / Max 1 %
Linearity error (εL)Typ None %
Error due to magnetic field of external conductor current (εIext)Min 0 / Typ ±0.4 / Max ±0.65 %

Note: Specifications are taken from the official ARU-B100-D250/SP4 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the ARU-B100-D250/SP4 are shown below.

ARU-B100-D250/SP4 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM ARU-B100-D250/SP4 datasheet
Outline Dimensions & Mechanical Data
Mass236 g
Case materialV0

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the ARU-B100-D250/SP4.

Outdoor substations
Distribution transformer monitoring
Medium voltage isolated cable distribution
Underground substations
Pole-mounted transformers
Low voltage overhead lines
Distributions system equipment. Standards

Characteristic Curves

The accuracy class characteristic diagram of the ARU-B100-D250/SP4 from the official datasheet is shown below.

ARU-B100-D250/SP4 accuracy class characteristic diagram
Accuracy class characteristic diagram — source: LEM ARU-B100-D250/SP4 datasheet
Accuracy & Dynamic Characteristics
Maximum secondary voltage (RMS) (USmax)30 V
Mutual inductance (M)Typ 321.9 nH
M Temperature coefficient of (TCM)Typ ±30 ppm/k
Ratio error (centered) (ε)Min −0.5 / Max 0.5 %
Ratio error (all positions) (ε)Min −1 / Max 1 %
Linearity error (εL)Typ None %
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Rated Frequency (fr)Typ 50/60 Hz

Note: For the full set of performance data, refer to the datasheet.