Your Trusted Source for Industrial Electrical Components

AT 20 B5

AC Current Transducer

LEM | AT-Series

self-poweredPower Supply
50/60 HzBandwidth (-1dB)
6 mmClearance (dCI)
600Comparative Tracking Index (CTI)
Over voltage category CAT · Pollution degree PD2Overvoltage Category / Pollution Degree

Additional Technical Details

View Full Specifications
Supply Voltageself-powered
Operating Temperature Range−20 … +60 °C
Isolation Test Voltage3.5 kV
Frequency Bandwidth (BW)50/60 Hz
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3.5 kV
Creepage Distance (dCp)6 mm

Standards & Approvals

Typical Applications

Automation and Supervision Current measurement for process regulation by distributed PLCs software), Safety and Condition Monitoring Load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The AT 20 B5 is a None current transducer from LEM.

Typical applications include Automation and Supervision Current measurement for process regulation by distributed PLCs software) and Safety and Condition Monitoring Load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors).

Key characteristics from the official datasheet: frequency bandwidth 50/60 Hz; operating temperature −20 … +60 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesAT
Product ReferenceAT 20 B5
Supply Voltageself-powered
Measurement—
Mounting—
Application DomainEnergy, Automation
Electrical Data — AT 20 B5
Supply Voltage (UC)self-powered
Accuracy & Dynamic Performance
Frequency Bandwidth (BW)50/60 Hz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3.5 kV
Creepage Distance (dCp)6 mm
Clearance (dCI)6 mm
Comparative Tracking Index (CTI)600
Overvoltage Category / Pollution DegreeOver voltage category CAT · Pollution degree PD2
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−20 … +60 °C
Ambient Storage Temperature (TA st)−20 … +85 °C
Mass (m)90 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: Specifications are taken from the official AT 20 B5 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the AT 20 B5 are shown below.

AT 20 B5 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM AT 20 B5 datasheet, page 4
Outline Dimensions & Mechanical Data
Mass90 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the AT 20 B5.

Automation and Supervision Current measurement for process regulation by distributed PLCs software)
Safety and Condition Monitoring Load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors)

Characteristic Curves

Characteristic curve diagrams are not included in the AT 20 B5 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Frequency Bandwidth (BW)50/60 Hz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination