Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series CAB Series CAB 500-C/SP5-012

CAB 500-C/SP5-012

Transducer using Fluxgate technology

LEM | CAB-Series | Fluxgate | Panel Mount

± 500 ANominal Primary Current
8 .. 16 VPower Supply
FluxgateTechnology
100 HzBandwidth (-1dB)
0.1 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 500 A
Supply Voltage8 .. 16 V
Operating Temperature Range−40 .. 85 °C
Primary Nominal Current (IPN)± 500 A
Current Consumption (IC)40 .. 45 mA
Insulation Resistance (RINS)500 MOhm

Standards & Approvals

Typical Applications

Ingress Protection - IP42 level.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The CAB 500-C/SP5-012 is a fluxgate current transducer from LEM delivering a output noise of ± 10 mA.

Typical applications include Ingress Protection - IP42 level.

Key characteristics from the official datasheet: linearity error 0.1 %; frequency bandwidth 100 Hz; operating temperature −40 .. 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesCAB
Product ReferenceCAB 500-C/SP5-012
Primary Nominal Current± 500 A
Supply Voltage8 .. 16 V
Measurement—
MountingPanel Mount
Application DomainIngress Protection - IP42 level
Electrical Data — CAB 500-C/SP5-012
Primary Nominal Current (IPN)± 500 A
Primary Current, Measuring Range (IPM)± 500 A
Supply Voltage (UC)8 .. 16 V
Current Consumption (IC)40 .. 45 mA
Insulation Resistance (RINS)500 MOhm
Accuracy & Dynamic Performance
Linearity Error0.1 %
Frequency Bandwidth100 Hz
Output Noise± 10 mA
Insulation Coordination
Creepage Distance (dCp)7.2 mm
Clearance (dCI)6.95 mm
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 .. 85 °C
IP LevelIP 42

Note: Specifications are taken from the official CAB 500-C/SP5-012 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the CAB 500-C/SP5-012 are shown below.

CAB 500-C/SP5-012 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM CAB 500-C/SP5-012 datasheet

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the CAB 500-C/SP5-012.

Ingress Protection - IP42 level

Characteristic Curves

The characteristic curves of the CAB 500-C/SP5-012 from the official datasheet are shown below.

CAB 500-C/SP5-012 characteristic curves
Characteristic curves — source: LEM CAB 500-C/SP5-012 datasheet
Accuracy & Dynamic Characteristics
Linearity Error0.1 %
Frequency Bandwidth100 Hz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment