Your Trusted Source for Industrial Electrical Components

CTSR 0.6-TP/SP2

Closed loop (compensated) current transducer

LEM | CTSR-Series | Closed loop (compensated) | EN 50178 | PCB Mount

600 mANominal Primary Current
4.75 ... 5.25 VPower Supply
Closed loop (compensated)Technology
9.5 kHzBandwidth (-1dB)
0.4 ... 1.3 % of IPRMLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Residual Current, Measuring Range-850 ... 850 mA
Accuracy (X)1.5 %
Step Response Time to 90 % of IPN30 µs
Isolation Test Voltage (50 Hz, 1 min)6 kV
Reference Voltage @ IP = 02.495 ... 2.505 V
Operating Temperature Range-40 … 105 °C

Standards & Approvals

  • EN 50178
  • IEC 61010-1
  • UL 508: 2010

Typical Applications

Residual current measurement, Leakage current measurement in transformerless PV inverters, First human contact protection of PV arrays, Failure detection in power sources, Symmetrical fault detection (e.g. after motor inverter), Leakage current detection in stacked DC sources, Single phase or three phase nominal current measurement.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The CTSR 0.6-TP/SP2 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation, delivering an instantaneous output voltage of 0.4 ... 1.1 V.

Typical applications include Residual current measurement, Leakage current measurement in transformerless PV inverters, First human contact protection of PV arrays and Failure detection in power sources.

Key characteristics from the official datasheet: linearity error 0.4 ... 1.3 % of IPRM; accuracy 1.5 %; operating temperature -40 … 105 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesCTSR
Product ReferenceCTSR 0.6-TP/SP2
Primary Nominal Current600 mA
Supply Voltage4.75 ... 5.25 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainSuitable to fulfil VDE 0126-1-1, UL 1741
Electrical Data — CTSR 0.6-TP/SP2
Primary Nominal Residual RMS Current (IPRN)600 mA
Primary Residual Current, Measuring Range (IPRM)-850 ... 850 mA
Supply Voltage (UC)4.75 ... 5.25 V
Current Consumption (IC)17.5 ... 21.6 mA
Output Voltage Referred to Vref (Test Current)0.4 ... 1.1 V
Reference Voltage @ IP = 0 (Vref)2.495 ... 2.505 V
External Reference Voltage (Vref)2.3 ... 4 V
Theoretical Sensitivity (Gth)2.476 V/A
Accuracy & Dynamic Performance
Sensitivity Error (εG)-0.7 ... 0.7 %
Linearity Error (εL)0.4 ... 1.3 % of IPRM
Accuracy (X)1.5 %
Electrical Offset Current Referred to Primary (IOE)-24 ... 24 mA
Magnetic Offset Current (IOM)17 mA
Temperature Coefficient of Vref (TCVref)±50 ppm/K
Temperature Coefficient of VOE (TCVOE)±520 ppm/K
Temperature Coefficient of G (TCG)±100 ppm/K
Output RMS Noise Voltage (1 Hz … 10 kHz) (Vno)4 mV
Reaction Time @ 10 % of IPRN (tra)5 µs
Step Response Time to 90 % of IPN (tr)30 µs
Frequency Bandwidth (-1 dB) (BW)9.5 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Impulse Withstand Voltage (1.2/50 µs) UNi11.2 kV
Partial Discharge Extinction RMS Voltage @ 10 pC (Ue)2.475 kV
Clearance (pri.-sec.) dCI13.5 mm
Creepage Distance (pri.-sec.) dCp33.2 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)-40 … 105 °C
Ambient Storage Temperature (TA st)-50 … 105 °C
Mass (m)55 g
Standards & Certifications
EN 501781997
IEC 61010-12010
UL 5082010

Note: Specifications are taken from the official CTSR 0.6-TP/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the CTSR 0.6-TP/SP2 are shown below.

CTSR 0.6-TP/SP2 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM CTSR 0.6-TP/SP2 datasheet
Outline Dimensions & Mechanical Data
Mass55 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the CTSR 0.6-TP/SP2.

Residual current measurement
Leakage current measurement in transformerless PV inverters
First human contact protection of PV arrays
Failure detection in power sources
Symmetrical fault detection (e.g. after motor inverter)
Leakage current detection in stacked DC sources
Single phase or three phase nominal current measurement

Characteristic Curves

The characteristic curves of the CTSR 0.6-TP/SP2 from the official datasheet are shown below.

CTSR 0.6-TP/SP2 characteristic curves
Characteristic curves — source: LEM CTSR 0.6-TP/SP2 datasheet
Accuracy & Dynamic Characteristics
Theoretical Sensitivity (Gth)2.476 V/A
Sensitivity Error (εG)-0.7 ... 0.7 %
Linearity Error (εL)0.4 ... 1.3 % of IPRM
Accuracy (X)1.5 %
Temperature Coefficient of Vref (TCVref)±50 ppm/K
Temperature Coefficient of VOE (TCVOE)±520 ppm/K
Temperature Coefficient of G (TCG)±100 ppm/K
Step Response Time to 90 % of IPN (tr)30 µs
Frequency Bandwidth (-1 dB) (BW)9.5 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment