Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors CV3 Series CV 3-1200

CV 3-1200

Closed loop (compensated) voltage transducer using the Hall effect

LEM | CV-Series | Closed loop (compensated) | EN 50155

1200 VNominal Primary Voltage
±15 VPower Supply
Closed loop (compensated)Technology
@ U DC … 800 kHzBandwidth (-1dB)
±0.2 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Supply Voltage±15 V
Operating Temperature Range−40 ... +85 °C
Isolation Test Voltage6 kV
Turns Ratio (NP/NS)1200 V : 10 V
Current Consumption (IC)32 + U S / R L mA
Frequency Bandwidth (BW)@ U DC … 800 kHz

Standards & Approvals

  • EN 50155: 2007
  • EN 50121-3-2

Typical Applications

Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The CV 3-1200 is a closed loop (compensated) current transducer from LEM for the electronic measurement of voltages: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±0.2 %; frequency bandwidth @ U DC … 800 kHz; operating temperature −40 ... +85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesCV
Product ReferenceCV 3-1200
Nominal Primary Voltage1200 V
Supply Voltage±15 V
Measurementvoltages: DC, AC, pulsed...
Mounting—
Application DomainRailway (fixed installations and onboard)
Electrical Data — CV 3-1200
Turns Ratio (NP/NS)1200 V : 10 V
Supply Voltage (UC)±15 V
Current Consumption (IC)32 + U S / R L mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.2 %
Frequency Bandwidth (BW)@ U DC … 800 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Creepage Distance (dCp)83.8 mm
Clearance (dCI)76.4 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−45 ... +90 °C
Mass (m)560 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.3 mm
Standards & Certifications
EN 501552007
EN 50121-3-2Compliance

Note: Specifications are taken from the official CV 3-1200 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the CV 3-1200 are shown below.

CV 3-1200 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM CV 3-1200 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.3 mm
Mass560 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the CV 3-1200.

Single or three phase inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
Battery chargers. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Route du Nant-d’Avril, 152 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the CV 3-1200 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.2 %
Frequency Bandwidth (BW)@ U DC … 800 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment