LEM | DHR-Series | for Safety | Panel Mount

1000 ANominal Primary Current
+ 20 .. 50 V DCPower Supply
DC 20..6000 HzBandwidth (-1dB)
< ± 1 % of ITotal Error @ IPN
4.0 kVRMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range1800 A
Supply Voltage+ 20 .. 50 V DC
Operating Temperature Range- 40 .. + 70 °C
Isolation Test Voltage4.0 kV
Primary Nominal RMS Current (IPN)1000 A
Current Consumption (IC)30 mA

Standards & Approvals

  • for Safety

Typical Applications

VFD Controlled Loads VFD output indicates how the motor and attached load are operating, SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement, Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The DHR 1000 C10 is a None current transducer from LEM.

Typical applications include VFD Controlled Loads VFD output indicates how the motor and attached load are operating, SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement and Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power.

Key characteristics from the official datasheet: total error < ± 1 % of I; frequency bandwidth DC 20..6000 Hz; operating temperature - 40 .. + 70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesDHR
Product ReferenceDHR 1000 C10
Primary Nominal Current1000 A
Supply Voltage+ 20 .. 50 V DC
Measurement—
MountingPanel Mount
Application DomainEnergy and Automation
Electrical Data — DHR 1000 C10
Primary Nominal RMS Current (IPN)1000 A
Primary Current, Measuring Range (IPM)1800 A
Supply Voltage (UC)+ 20 .. 50 V DC
Current Consumption (IC)30 mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN< ± 1 % of I
Frequency Bandwidth (BW)DC 20..6000 Hz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.0 kV
Impulse Withstand Voltage (1.2/50 µs) UNi7.3 kV
Creepage Distance (dCp)7.2 mm
Comparative Tracking Index (CTI)600
Overvoltage Category / Pollution DegreeOver voltage category CAT · Pollution degree PD2
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 40 .. + 70 °C
Ambient Storage Temperature (TA st)- 40 .. + 85 °C
Mass (m)260 g
Standards & Certifications
for Safety

Note: Specifications are taken from the official DHR 1000 C10 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the DHR 1000 C10 are shown below.

DHR 1000 C10 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM DHR 1000 C10 datasheet, page 4
Outline Dimensions & Mechanical Data
Mass260 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the DHR 1000 C10.

VFD Controlled Loads VFD output indicates how the motor and attached load are operating
SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement
Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power

Characteristic Curves

Characteristic curve diagrams are not included in the DHR 1000 C10 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN< ± 1 % of I
Frequency Bandwidth (BW)DC 20..6000 Hz

Note: For the full set of performance data, refer to the datasheet.