Your Trusted Source for Industrial Electrical Components
Home Products LEM Industrial Drive, Welding & New Energy Power Supply EM4T Series EM4TII AC-MS DC-MS +XPS 110VDC, RS232

EM4TII AC-MS DC-MS +XPS 110VDC, RS232

Single-phase energy meter for energy measurement on board trains

LEM | EM4-Series | Energy Meter | EN 50463 | Wall Mount

25 kV AC / 3 kV DCMax. Traction System Voltage
110 V DCSupply Voltage
Class 0.5 RAccuracy Class
DC / 16.7 / 50 / 60 HzSystem Frequencies
DC, 16.7 Hz, 50 Hz and 60 HzFrequency

Additional Technical Details

View Full Specifications
Nominal CharacteristicsAC 15 kV / 16.7 Hz · 25 kV / 50 Hz · DC 750 V / 1.5 kV / 3 kV
AccuracyClass 0.5 R (as per EN 50463-2)
Operating Temperature Range-40 °C … +75 °C
Measuring Input Channels4 galvanically isolated inputs for U- and I-sensors (AC, DC or ACDC)
Rated Voltage (secondary)AC: 70 – 300 V or 17,9 – 100 mA; DC: 17,9 – 100 mA
Rated Current (secondary)AC: 50 – 2000 mA or 5 A; DC: 50 – 2000 mA

Standards & Approvals

  • EN 50463:2017 Railway applications — Energy measurement on board trains
  • EN 50155 Railway applications — Electronic equipment used on rolling stock
  • EN 50121-3-2:2016 Railway applications — Electromagnetic compatibility — Rolling stock apparatus
  • EN 61373:2010 Railway applications — Shock and vibration tests
  • EN 50124-1:2017 Railway applications — Insulation coordination
  • IEC 62056-21:2002 Electricity metering — Direct local data exchange
  • EN 50163:2004 Railway applications — Supply voltages of traction systems

Typical Applications

Railway applications — on-board energy measurement for multi-system traction vehicles.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The EM4TII AC-MS DC-MS +XPS 110VDC, RS232 is a None current transducer from LEM for the electronic measurement of Active and reactive energy, with galvanic isolation.

The accuracy class is 0.5 R (as per EN 50463-2). Typical applications include Multi-System Locomotives, Traction Energy Metering & Billing and Railway Vehicles (25 kV / 15 kV AC, 750 V / 1.5 kV / 3 kV DC).

The EM4TII+ is a single-phase energy meter as per EN 50463:2017, meeting the requirements of EU directive 1302/2014/EU for energy measurement on board trains. It processes signals from transformer-based and electronic transducer systems for current and voltage, and generates a load profile from the calculated energy values — consumed and regenerated active and reactive energy are recorded in separate registers and stored for at least 300 days at the default 5-minute period length.

Designed for multi-system vehicles, the meter operates on 25 kV / 50 Hz and 15 kV / 16.7 Hz AC networks as well as 750 V, 1.5 kV and 3 kV DC systems; a system change is detected automatically and recorded in the load profile and the logbook. All measured and stored data can be read out via serial interfaces (RS232, RS422 or RS485) using the IEC 62056-21 protocol, and an RS232 GPS input (NMEA 0183) provides location coordinates and automatic clock synchronisation.

The compact, fireproof housing is protected to IP65 and meets the railway requirements of EN 50155, EN 50121-3-2, EN 50124-1 and EN 61373 (shock and vibration tested to category 1, class B). The supply voltage can be selected between 24 V and 110 V as per EN 50155 — this variant is factory-configured for 110 V DC supply with an RS232 communication interface.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesEM4
Product ReferenceEM4TII AC-MS DC-MS +XPS 110VDC, RS232
Max. Traction System Voltage25 kV AC / 3 kV DC
Supply Voltage24 – 48 V or 72 – 110 V (as per EN 50155); this unit: 110 V DC
MeasurementActive and reactive energy (consumed and regenerated)
MountingWall mounting (three-point, as per DIN 43857-2)
Application DomainRailway traction — on-board energy measurement
Technical Data
Measuring Input Channels4 galvanically isolated inputs for U- and I-sensors (AC, DC or ACDC)
Rated Voltage (secondary)AC: 70 – 300 V or 17,9 – 100 mA; DC: 17,9 – 100 mA
Rated Current (secondary)AC: 50 – 2000 mA or 5 A; DC: 50 – 2000 mA
Accuracy Class0.5 R (as per EN 50463-2)
FrequencyDC, 16.7 Hz, 50 Hz and 60 Hz
Load ProfileActive and reactive energy (kWh / kvarh); period length min. 1 minute
Memory DepthAt least 300 days (5-minute period length)
Clock Accuracy< 20 ppm
Interfaces1 × RS232 / RS422 / RS485 (bidirectional); 1 × RS232 for GPS (NMEA 0183)
DisplayLCD, self-luminous, letter height approx. 4 mm
Degree of ProtectionIP65
Supply Voltage24 – 48 V or 72 – 110 V (as per EN 50155); this unit: 110 V DC
Power Consumption3 W (without modem)
Inrush Current500 mA max (without modem supply)
Operating Temperature-40 °C … +75 °C
Storage Temperature-40 °C … +85 °C
Weightapprox. 1.5 kg

Note: Specifications are taken from the official EM4TII AC-MS DC-MS +XPS 110VDC, RS232 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the EM4TII AC-MS DC-MS +XPS 110VDC, RS232 are shown below.

EM4TII AC-MS DC-MS +XPS  110VDC, RS232 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM EM4TII AC-MS DC-MS +XPS 110VDC, RS232 datasheet
Outline Dimensions & Mechanical Data
Weightapprox. 1.5 kg

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the EM4TII AC-MS DC-MS +XPS 110VDC, RS232.

Multi-System Locomotives
Traction Energy Metering & Billing
Railway Vehicles (25 kV / 15 kV AC, 750 V / 1.5 kV / 3 kV DC)

Characteristic Curves

Characteristic curve diagrams are not included in the EM4TII AC-MS DC-MS +XPS 110VDC, RS232 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Accuracy Class0.5 R (as per EN 50463-2)
Clock Accuracy< 20 ppm
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Accuracy Class0.5 R (as per EN 50463-2)

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment