4.5 ... 5.5 VPower Supply
open loopTechnology
100 ... −1 kHzBandwidth (-1dB)
−0.5 ... 0.5 % of IPNLinearity Error (Max)
Typ 600 mV/mTNominal sensitivity (SN)

Additional Technical Details

View Full Specifications
Output Voltage Range0.5 ... 4.5 V
Supply Voltage4.5 ... 5.5 V
Current Consumption (IC)12 ... 19 mA (typ 14 mA)
DC supply voltage (UC)Min 4.5 / Typ 5 / Max 5.5 V
Magnetic flux density measuring range (BM)Typ ±3.3 mT
B Output voltage in a flux density (Uout)Min 0.5 / Max 4.5 V

Standards & Approvals

Typical Applications

Small drives, BMS, Motor control, UPS, HVAC, White goods, PCB track current sensing. Figure 1: FHS AH package - SOIC-8 Page 1/17 modifications on its transducers, LEM International SA Route du Nant-d’Avril, 152 www.lem.com

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The FHS AH 600 is an open loop current transducer from LEM delivering a output sink current of −50 mA.

Typical applications include Small drives, BMS, Motor control and UPS.

Key characteristics from the official datasheet: linearity error −0.5 ... 0.5 % of IPN; frequency bandwidth 100 ... −1 kHz.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesFHS
Product ReferenceFHS AH 600
Supply Voltage4.5 ... 5.5 V
Measurement—
MountingBusbar Mount
Application Domain—
Electrical Data — FHS AH 600
Supply Voltage (UC)4.5 ... 5.5 V
Current Consumption (IC)12 ... 19 mA (typ 14 mA)
DC supply voltage (UC)Min 4.5 / Typ 5 / Max 5.5 V
Magnetic flux density measuring range (BM)Typ ±3.3 mT
B Output voltage in a flux density (Uout)Min 0.5 / Max 4.5 V
Nominal sensitivity (SN)Typ 600 mV/mT
Sensitivity error (εS)Min −1 / Typ ±0.5 / Max 1 %
S Temperature coefficient of (TCS)Min −200 / Max 200 ppm/K
Lifetime sensitivity drift (SL)Typ ±1.5 %
U Output internal resistance of ref (RIref)Min 120 / Typ 200 / Max 333 Ω
Electrical offset voltage (UOE)Min −10 / Max 10 mV
Lifetime offset drift (UOEL)Typ ±15 mV
Remanent field/Magnetic offset (UOM)Min −9 / Max 9 mV
U Temperature coefficient of ref (TCUref)Min −150 / Max 150 ppm/K
U Output internal resistance of out (Rout)Max 5 Ω
Delay time to 10 % of the final output B step value for N (tD10)Max 2 µs
Delay time to 90 % of the final output B value for step N (tD90)Max 2 µs
Internal OCD detection threshold (BIOCDTh)Typ 4.8 mT
Internal OCD threshold error (εIOCDTh)Min −10 / Max 10 %
Internal OCD output on resistance (RonIOCD)Min 70 / Typ 95 / Max 150 Ω
Internal OCD output hold time (tholdIOCD)Min 7 / Typ 10 / Max 14 µs
Internal OCD delay time (tDIOCD)Min 1.3 / Max 2.1 µs
External OCD threshold error (εEOCDTh)Min −5 / Max 5 %
External OCD output on resistance (RonEOCD)Min 35 / Typ 200 / Max 280 Ω
External OCD output hold time (tholdEOCD)Typ 10 µs
External OCD delay time (tDEOCD)Typ 10 µs
Setting External OCD threshold: The external Over-Current-Detection threshold formula: (isdirectlyRE)Min with the / Typ external / Max resistors set by user
E OCD The corresponding sensed magnetic field threshold following formula: (+RREEisdefined−UUrefEOCD)Min external / Typ voltage / Max threshold ref ref by the
Absolute Maximum Ratings
Ambient operating temperature (TA)−40 ... +125 °C
Absolute Maximum Ratings
Ambient storage temperature (TAst)−55 ... +165 °C
Absolute Maximum Ratings
Maximum junction temperature (TJmax)165 °C
Absolute Maximum Ratings
Output sink current−50 mA
Absolute Maximum Ratings
Output source current25 mA
Absolute Maximum Ratings
Magnetic flux density (Bmax)±3 T
Accuracy & Dynamic Performance
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Electrical Offset Voltage (VO E) @ IP = 0−10 ... 10 mV
Frequency Bandwidth100 ... −1 kHz
Sample1
Environmental & Mechanical
Maximum supply voltage (UCmax)8 V
Electrostatic discharge voltage (HBM-Human Body Model) (UESDHBM)2 kV
Electrostatic discharge voltage (CDM -Charged Device Model) (UESDCDM)500 V

Note: Specifications are taken from the official FHS AH 600 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the FHS AH 600 are shown below.

FHS AH 600 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM FHS AH 600 datasheet

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the FHS AH 600.

Small drives
Motor control
White goods
PCB track current sensing. Figure 1: FHS AH package - SOIC-8 Page 1/17 modifications on its transducers, LEM International SA Route du Nant-d’Avril, 152 www.lem.com

Characteristic Curves

The characteristic curves of the FHS AH 600 from the official datasheet are shown below.

FHS AH 600 characteristic curves
Characteristic curves — source: LEM FHS AH 600 datasheet
Accuracy & Dynamic Characteristics
Nominal sensitivity (SN)Typ 600 mV/mT
Sensitivity error (εS)Min −1 / Typ ±0.5 / Max 1 %
S Temperature coefficient of (TCS)Min −200 / Max 200 ppm/K
Lifetime sensitivity drift (SL)Typ ±1.5 %
U Temperature coefficient of ref (TCUref)Min −150 / Max 150 ppm/K
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Frequency Bandwidth100 ... −1 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.