FRS 3000-S

Open Loop

LEM | FRS-Series | Open Loop | IEC 62477-1 | Busbar Mount

3000 ANominal Primary Current
10 ... 28 VPower Supply
Open LoopTechnology
1000 kHzBandwidth (-1dB)
−0.35 ... 0.35 % of IPNLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 ... 9000 A
Output Voltage Range−2 ... 2 V
Supply Voltage10 ... 28 V
Accuracy @ IPN−0.5 ... 0.5 % of IPN
Operating Temperature Range−40 ... +85 °C
Isolation Test Voltage12 kV

Standards & Approvals

  • IEC 62477-1
  • IEC 61800-5-1
  • IEC 62109-1
  • IEC 61010-1
  • EN 50155
  • IEC 61992-7-2
  • UL 61010-1: 3ED 2022

Typical Applications

Wind turbine power converter, Electrolyser, High power drives.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The FRS 3000-S is an open loop current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include Wind turbine power converter, Electrolyser, High power drives and IEC 62477-1: 2022.

Key characteristics from the official datasheet: linearity error −0.35 ... 0.35 % of IPN; frequency bandwidth 1000 kHz; operating temperature −40 ... +85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesFRS
Product ReferenceFRS 3000-S
Primary Nominal Current3000 A
Supply Voltage10 ... 28 V
Measurementcurrent: DC, AC, pulsed...
MountingBusbar Mount
Application DomainIndustrial, Traction, Trackside
Electrical Data — FRS 3000-S
Primary Nominal RMS Current (IPN)3000 A
Primary Current, Measuring Range (IPM)0 ... 9000 A
Supply Voltage (UC)10 ... 28 V
Current Consumption (IC)60 ... 80 mA
Accuracy & Dynamic Performance
Accuracy @ IPN−0.5 ... 0.5 % of IPN
Linearity Error (εL)−0.35 ... 0.35 % of IPN
Response Time to 90 % of IPN Step0.2 µs
Frequency Bandwidth1000 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud12 kV
Impulse Withstand Voltage (1.2/50 µs) UNi44 kV
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−40 ... +90 °C
Mass (m)472 g
Standards & Certifications
IEC 62477-1Compliance
IEC 61800-5-1Compliance
IEC 62109-1Compliance
IEC 61010-1Compliance
EN 50155Compliance
IEC 61992-7-2Compliance
UL 61010-13ED 2022.

Note: Specifications are taken from the official FRS 3000-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the FRS 3000-S are shown below.

FRS 3000-S outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM FRS 3000-S datasheet
Outline Dimensions & Mechanical Data
Mass472 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the FRS 3000-S.

Wind turbine power converter
Electrolyser
High power drives
IEC 62477-1: 2022
IEC 61800-5-1: 2022
IEC 62109-1: 2010
IEC 61010-1: 2010

Characteristic Curves

The characteristic curves of the FRS 3000-S from the official datasheet are shown below.

FRS 3000-S characteristic curves
Characteristic curves — source: LEM FRS 3000-S datasheet
Accuracy & Dynamic Characteristics
Accuracy @ IPN−0.5 ... 0.5 % of IPN
Linearity Error (εL)−0.35 ... 0.35 % of IPN
Response Time to 90 % of IPN Step0.2 µs
Frequency Bandwidth1000 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment