Your Trusted Source for Industrial Electrical Components
Home Products LEM Automotive Series HAH Series HAH1BVW S/D08

HAH1BVW S/D08

Ratiometric transducer

LEM | HAH-Series | Open Loop Transducer | Busbar Mount

± 1200 A / ± 350 ANominal Primary Current
4.5 .. 5.5 VPower Supply
Open Loop TransducerTechnology
70 HzBandwidth (-1dB)
20 mACurrent Consumption (IC)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range± 1200 A / ± 350 A
Supply Voltage4.5 .. 5.5 V
Sensitivity1.67 / 5.71 mV/A
Operating Temperature Range−40 .. 125 °C
Isolation Test Voltage2.5 kV
Primary Nominal Current (IPN)± 1200 A / ± 350 A

Standards & Approvals

Typical Applications

Dual output.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HAH1BVW S/D08 is an open loop current transducer from LEM for the electronic measurement of DC, and low frequency current, with galvanic isolation, delivering an instantaneous output voltage of 2.5 V.

It offers excellent accuracy and very good linearity. Typical applications include Dual output.

Key characteristics from the official datasheet: frequency bandwidth 70 Hz; operating temperature −40 .. 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHAH
Product ReferenceHAH1BVW S/D08
Primary Nominal Current± 1200 A / ± 350 A
Supply Voltage4.5 .. 5.5 V
MeasurementDC, and low frequency current
MountingBusbar Mount
Application DomainDual output
Electrical Data — HAH1BVW S/D08
Primary Nominal Current (IPN)± 1200 A / ± 350 A
Primary Current, Measuring Range (IPM)± 1200 A / ± 350 A
Supply Voltage (UC)4.5 .. 5.5 V
Current Consumption (IC)20 mA
Sensitivity1.67 / 5.71 mV/A
Output Offset Voltage (VO E)2.5 V
Load Resistance (RL)10 kOhm
Accuracy & Dynamic Performance
Ratiometricity Error± 0.2 %
Sensitivity Error± 1 %
Delay Time (tD)10 ms
Frequency Bandwidth70 Hz
Output Noise10 mV
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Creepage Distance (dCp)4.85 mm
Clearance (dCI)4.85 mm
Comparative Tracking Index (CTI)PLC3 (175 V - 250 V)
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 .. 125 °C
Ambient Storage Temperature (TA st)−40 .. 125 °C
Mass (m)57 g

Note: Specifications are taken from the official HAH1BVW S/D08 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HAH1BVW S/D08 are shown below.

HAH1BVW S/D08 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HAH1BVW S/D08 datasheet
Outline Dimensions & Mechanical Data
Mass57 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HAH1BVW S/D08.

Dual output

Characteristic Curves

The characteristic curves of the HAH1BVW S/D08 from the official datasheet are shown below.

HAH1BVW S/D08 characteristic curves
Characteristic curves — source: LEM HAH1BVW S/D08 datasheet
Accuracy & Dynamic Characteristics
Sensitivity1.67 / 5.71 mV/A
Sensitivity Error± 1 %
Frequency Bandwidth70 Hz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)10 kOhm

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment