Open Loop transducer using the Hall effect sensor
| Primary Current, Measuring Range | ± 660 A |
| Supply Voltage | 4.90 .. 5.10 V |
| Sensitivity | 3.030 mV/A |
| Operating Temperature Range | −40 .. 125 °C |
| Isolation Test Voltage | 2.5 kV |
| Primary Nominal Current (IPN) | ± 660 A |
Simplified installation with press fit contacts eliminates a constant soldering. b constant.
The HAH3DR 660-S07/SP2 is an open loop current transducer from LEM delivering an instantaneous output voltage of 2.5 V.
It offers excellent accuracy and very good linearity. Typical applications include Simplified installation with press fit contacts eliminates a constant soldering. b constant.
Key characteristics from the official datasheet: linearity error ± 0.5 %; frequency bandwidth 40 kHz; operating temperature −40 .. 125 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | HAH |
| Product Reference | HAH3DR 660-S07/SP2 |
| Primary Nominal Current | ± 660 A |
| Supply Voltage | 4.90 .. 5.10 V |
| Measurement | — |
| Mounting | Busbar Mount |
| Application Domain | Simplified installation with press fit contacts eliminates a constant soldering. b constant |
| Electrical Data — HAH3DR 660-S07/SP2 | |
|---|---|
| Primary Nominal Current (IPN) | ± 660 A |
| Primary Current, Measuring Range (IPM) | ± 660 A |
| Supply Voltage (UC) | 4.90 .. 5.10 V |
| Current Consumption (IC) | 45 .. 60 mA |
| Sensitivity | 3.030 mV/A |
| Output Offset Voltage (VO E) | 2.5 V |
| Load Resistance (RL) | 10 kOhm |
| Insulation Resistance (RINS) | 500 MOhm |
| Accuracy & Dynamic Performance | |
|---|---|
| Ratiometricity Error | ± 0.3 % |
| Sensitivity Error | 1 % |
| Linearity Error | ± 0.5 % |
| Delay Time (tD) | 2 .. 6 µs |
| Frequency Bandwidth | 40 kHz |
| Output Noise | 20 mV |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 2.5 kV |
| Creepage Distance (dCp) | 6.4 mm |
| Clearance (dCI) | 5.4 mm |
| Comparative Tracking Index (CTI) | PLC3 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 .. 125 °C |
| Ambient Storage Temperature (TA st) | −40 .. 125 °C |
| Mass (m) | 80 g |
Note: Specifications are taken from the official HAH3DR 660-S07/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the HAH3DR 660-S07/SP2.
Outline dimensions, pin layout and connection diagrams of the HAH3DR 660-S07/SP2 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 80 g |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the HAH3DR 660-S07/SP2.
The characteristic curves of the HAH3DR 660-S07/SP2 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Sensitivity | 3.030 mV/A |
| Sensitivity Error | 1 % |
| Linearity Error | ± 0.5 % |
| Frequency Bandwidth | 40 kHz |
| Reference Conditions | |
|---|---|
| Ambient Temperature (TA) | 25 °C, unless otherwise noted |
| Output Load Resistance (RL) | 10 kOhm |
Note: Refer to the datasheet for the complete set of characteristic curves.