Authorized Distributor
?
Hall effect measuring principle
| Supply Voltage | ±15 V |
| Accuracy @ IPN | ±1 % |
| Operating Temperature Range | −40 ... +105 6) °C |
| Isolation Test Voltage | 3.6 kV |
| Current Consumption (IC) | ±15 mA |
| Accuracy @ IPN, TA = 25 °C, ±15 V | ±1 % |
AC variable speed drivers and servo drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.
The HAS 200-S/SP105 is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
Typical applications include AC variable speed drivers and servo drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).
Key characteristics from the official datasheet: linearity error ±1 %; frequency bandwidth DC ... 50 kHz; operating temperature −40 ... +105 6) °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | HAS |
| Product Reference | HAS 200-S/SP105 |
| Supply Voltage | ±15 V |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | Busbar Mount |
| Application Domain | Industrial |
| Electrical Data — HAS 200-S/SP105 | |
|---|---|
| Supply Voltage (UC) | ±15 V |
| Current Consumption (IC) | ±15 mA |
| Accuracy & Dynamic Performance | |
|---|---|
| Accuracy @ IPN, TA = 25 °C, ±15 V | ±1 % |
| Linearity Error (εL) (0 ... ±IPN) | ±1 % |
| Electrical Offset Voltage (VO E) @ IP = 0, TA = 25 °C | < ±20 mV |
| Frequency Bandwidth (−3 dB) | DC ... 50 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 3.6 kV |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... +105 6) °C |
| Ambient Storage Temperature (TA st) | −40 ... +105 °C |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| General Tolerance | ±0.5 mm |
| Standards & Certifications | |
|---|---|
| UL UL 508:2010 | |
Note: Specifications are taken from the official HAS 200-S/SP105 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the HAS 200-S/SP105.
Outline dimensions, pin layout and connection diagrams of the HAS 200-S/SP105 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| General Tolerance | ±0.5 mm |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the HAS 200-S/SP105.
Characteristic curve diagrams are not included in the HAS 200-S/SP105 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Accuracy @ IPN, TA = 25 °C, ±15 V | ±1 % |
| Linearity Error (εL) (0 ... ±IPN) | ±1 % |
| Frequency Bandwidth (−3 dB) | DC ... 50 kHz |
Note: For the full set of performance data, refer to the datasheet.