HLSR 40-SM/SP33

Open loop

LEM | HLSR-Series | Open loop | EN 50178 | PCB Mount

40 ANominal Primary Current
3.135 ... 3.465 VPower Supply
Open loopTechnology
450 kHzBandwidth (-1dB)
−0.5 ... 0.5 % of IPNLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−100 ... 100 A
Output Voltage Range−1.15 ... 1.15 V
Supply Voltage3.135 ... 3.465 V
Accuracy @ IPN−1 ... 1 % of IPN
Operating Temperature Range105 °C
Isolation Test Voltage4.3 kV

Standards & Approvals

  • EN 50178
  • IEC 61010-1
  • IEC 61326-1
  • UL 508: 2010

Typical Applications

AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications, Combiner box, MPPT.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HLSR 40-SM/SP33 is an open loop current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

Typical applications include AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error −0.5 ... 0.5 % of IPN; frequency bandwidth 450 kHz; operating temperature 105 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHLSR
Product ReferenceHLSR 40-SM/SP33
Primary Nominal Current40 A
Supply Voltage3.135 ... 3.465 V
Measurementcurrents: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — HLSR 40-SM/SP33
Primary Nominal RMS Current (IPN)40 A
Primary Current, Measuring Range (IPM)−100 ... 100 A
Supply Voltage (UC)3.135 ... 3.465 V
Current Consumption (IC)19 ... 25 mA
Resistance of Primary Winding (RP)0.21 mΩ
Accuracy & Dynamic Performance
Accuracy @ IPN−1 ... 1 % of IPN
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Electrical Offset Voltage (VO E) @ IP = 0−5 ... 5 mV
Response Time to 90 % of IPN Step2.5 µs
Frequency Bandwidth450 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Creepage Distance (dCp)8 mm
Clearance (dCI)8 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)105 °C
Ambient Storage Temperature (TA st)105 °C
Mass (m)5 g
Standards & Certifications
EN 50178Compliance
IEC 61010-1:
IEC 61326-1:
UL 5082010.

Note: Specifications are taken from the official HLSR 40-SM/SP33 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HLSR 40-SM/SP33 are shown below.

HLSR 40-SM/SP33 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HLSR 40-SM/SP33 datasheet
Outline Dimensions & Mechanical Data
Mass5 g
Resistance of Primary Winding (RP)0.21 mΩ

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HLSR 40-SM/SP33.

AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box

Characteristic Curves

The characteristic curves of the HLSR 40-SM/SP33 from the official datasheet are shown below.

HLSR 40-SM/SP33 characteristic curves
Characteristic curves — source: LEM HLSR 40-SM/SP33 datasheet
Accuracy & Dynamic Characteristics
Accuracy @ IPN−1 ... 1 % of IPN
Linearity Error (εL)−0.5 ... 0.5 % of IPN
Response Time to 90 % of IPN Step2.5 µs
Frequency Bandwidth450 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.