Your Trusted Source for Industrial Electrical Components

HMSR 8-SMS

open loop

LEM | HMSR-Series | open loop | IEC 61800-5-1 | PCB Mount

8 ANominal Primary Current
4.5 ... 5.5 VPower Supply
open loopTechnology
300 kHzBandwidth (-1dB)
−1.5 ... 1.5 % of IPNLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−20 ... 20 A
Output Voltage Range−2 ... 2 V
Supply Voltage4.5 ... 5.5 V
Accuracy @ IPN−1.5 ... 1.5 % of IPN
Operating Temperature Range−40 ... 125 °C
Isolation Test Voltage4.95 kV

Standards & Approvals

  • IEC 61800-5-1
  • IEC 62109-1
  • IEC 60950-1
  • UL 1577: 2014

Typical Applications

Small drives, HVAC Inverters, Appliances, Solar Inverters.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HMSR 8-SMS is an open loop current transducer from LEM for the electronic measurement of DC and AC currents, with galvanic isolation.

Typical applications include Small drives, HVAC Inverters, Appliances and Solar Inverters.

Key characteristics from the official datasheet: linearity error −1.5 ... 1.5 % of IPN; frequency bandwidth 300 kHz; operating temperature −40 ... 125 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHMSR
Product ReferenceHMSR 8-SMS
Primary Nominal Current8 A
Supply Voltage4.5 ... 5.5 V
MeasurementDC and AC currents
MountingPCB Mount
Application DomainIndustrial
Electrical Data — HMSR 8-SMS
Primary Nominal RMS Current (IPN)8 A
Primary Current, Measuring Range (IPM)−20 ... 20 A
Supply Voltage (UC)4.5 ... 5.5 V
Current Consumption (IC)20 ... 26 mA
Accuracy & Dynamic Performance
Accuracy @ IPN−1.5 ... 1.5 % of IPN
Linearity Error (εL)−1.5 ... 1.5 % of IPN
Electrical Offset Voltage (VO E) @ IP = 0−5 ... 5 mV
Response Time to 90 % of IPN Step2 µs
Frequency Bandwidth300 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.95 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Creepage Distance (dCp)8 mm
Clearance (dCI)8 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 125 °C
Ambient Storage Temperature (TA st)−55 ... 165 °C
Mass (m)1.4 g
Standards & Certifications
IEC 61800-5-1:
IEC 62109-1:
IEC 60950-1:
UL 15772014.

Note: Specifications are taken from the official HMSR 8-SMS datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HMSR 8-SMS are shown below.

HMSR 8-SMS outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HMSR 8-SMS datasheet
Outline Dimensions & Mechanical Data
Mass1.4 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HMSR 8-SMS.

Small drives
HVAC Inverters
Appliances
Solar Inverters
IEC 61800-5-1: 2007
IEC 62109-1: 2010
IEC 60950-1: 2005

Characteristic Curves

The characteristic curves of the HMSR 8-SMS from the official datasheet are shown below.

HMSR 8-SMS characteristic curves
Characteristic curves — source: LEM HMSR 8-SMS datasheet
Accuracy & Dynamic Characteristics
Accuracy @ IPN−1.5 ... 1.5 % of IPN
Linearity Error (εL)−1.5 ... 1.5 % of IPN
Response Time to 90 % of IPN Step2 µs
Frequency Bandwidth300 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment