Your Trusted Source for Industrial Electrical Components

HTA 100-S

Open loop transducer using Hall effect

LEM | HTA-Series | Open loop transducer | EN 50178 | Panel Mount

100 ANominal Primary Current
±15 VPower Supply
Open loop transducerTechnology
DC ... 50 kHzBandwidth (-1dB)
±0.5 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range±300 A
Output Voltage (Analog) @ IPN±4 V
Supply Voltage±15 V
Accuracy @ IPN±1 % of IPN
Operating Temperature Range−25 ... +85 °C
Isolation Test Voltage4.0 kV

Standards & Approvals

  • EN 50178: 1997

Typical Applications

AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HTA 100-S is an open loop current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation, delivering an instantaneous output voltage of ±4 V.

It offers very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error ±0.5 %; frequency bandwidth DC ... 50 kHz; operating temperature −25 ... +85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHTA
Product ReferenceHTA 100-S
Primary Nominal Current100 A
Supply Voltage±15 V
Measurementcurrents: DC, AC, pulsed...
MountingPanel Mount
Application DomainIndustrial
Electrical Data — HTA 100-S
Primary Nominal RMS Current (IPN)100 A
Primary Current, Measuring Range (IPM)±300 A
Output Voltage (Analog) @ IPN±4 V
Load Resistance (RL)> 1 kΩ (TA = 0 ... +70 °C); > 3 kΩ (TA = −25 ... +85 °C)
Supply Voltage (UC)±15 V
Current Consumption (IC)< 25 mA
Insulation Resistance (RINS)> 500 MΩ
Accuracy & Dynamic Performance
Accuracy @ IPN, TA = 25 °C, ±15 V±1 % of IPN
Linearity Error (εL) (0 ... ±IPN)±0.5 %
Electrical Offset Voltage (VO E) @ IP = 0, TA = 25 °C< ±10 mV
Magnetic Offset Voltage (VO M) after an overload of 3 × IPN±10 mV
Temperature Coefficient of VO E (−25 ... +85 °C)< ±1 mV/K
Temperature Coefficient of Vout (−25 ... +85 °C)< ±0.05 %/K
Frequency Bandwidth (−3 dB)DC ... 50 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.0 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−25 ... +85 °C
Ambient Storage Temperature (TA st)−25 ... +85 °C
Mass (m)230 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±1 mm
Standards & Certifications
EN 501781997

Note: Specifications are taken from the official HTA 100-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HTA 100-S are shown below.

HTA 100-S outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HTA 100-S datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass230 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HTA 100-S.

AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications

Characteristic Curves

Characteristic curve diagrams are not included in the HTA 100-S datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Accuracy @ IPN, TA = 25 °C, ±15 V±1 % of IPN
Linearity Error (εL) (0 ... ±IPN)±0.5 %
Temperature Coefficient of VO E (−25 ... +85 °C)< ±1 mV/K
Temperature Coefficient of Vout (−25 ... +85 °C)< ±0.05 %/K
Frequency Bandwidth (−3 dB)DC ... 50 kHz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)> 1 kΩ (TA = 0 ... +70 °C); > 3 kΩ (TA = −25 ... +85 °C)

Note: For the full set of performance data, refer to the datasheet.