Your Trusted Source for Industrial Electrical Components

HTFS 400-P

Hall effect measuring principle

LEM | HTFS-Series | PCB Mount

DC ... 240 kHzBandwidth (-1dB)
±0.5 %Linearity Error (Max)
≥ 2 kΩLoad resistance
< 5 ΩOutput internal resistance
= 4.7 nFLoad capacitance

Additional Technical Details

View Full Specifications
Accuracy @ IPN±1 %
Operating Temperature Range‒40 ... +105 °C
Isolation Test Voltage2.5 kV
Current Consumption (IC)@ U = 5 V 19 (typ) mA
Output impedancetyp. 200 Ω
Load impedance≥ 200 kΩ

Standards & Approvals

Typical Applications

Forklift drives, AC variable speed drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HTFS 400-P is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation, delivering a output impedance of typ. 200 Ω.

Typical applications include Forklift drives, AC variable speed drives, Static converters for DC motor drives and Battery supplied applications.

Key characteristics from the official datasheet: linearity error ±0.5 %; frequency bandwidth DC ... 240 kHz; operating temperature ‒40 ... +105 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHTFS
Product ReferenceHTFS 400-P
Supply Voltage5 V
Measurementcurrents: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — HTFS 400-P
Current Consumption (IC)@ U = 5 V 19 (typ) mA
Output impedancetyp. 200 Ω
Load impedance≥ 200 kΩ
Load resistance≥ 2 kΩ
Output internal resistance< 5 Ω
Load capacitance= 4.7 nF
Supply voltage (±5 %)5 V
Accuracy & Dynamic Performance
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %
Linearity Error (εL) (0 ... ±IPN)±0.5 %
Frequency Bandwidth (−3 dB)DC ... 240 kHz
Linearity error 0 ... 1.5 I (ε)≤ ±0.5 %
TCU Temperature coefficient of U≤ ±190 ppm/K
TCS Temperature coefficient of U≤ ±420 ppm/K
RMS noise voltage referred to primary (DC ... 20 MHz) (U)< 40 mVpp
BW Frequency bandwidth (‒3 dB)DC ... 240 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud2.5 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)‒40 ... +105 °C
Ambient Storage Temperature (TA st)‒40 ... +105 °C
Mass (m)60 g
Case MaterialInsulating plastic case recognized according to UL 94-V0

Note: Specifications are taken from the official HTFS 400-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HTFS 400-P are shown below.

HTFS 400-P outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HTFS 400-P datasheet, page 4
Outline Dimensions & Mechanical Data
Mass60 g
Case MaterialInsulating plastic case recognized according to UL 94-V0

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HTFS 400-P.

Forklift drives
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications

Characteristic Curves

The characteristic curves of the HTFS 400-P from the official datasheet are shown below.

HTFS 400-P characteristic curves
Characteristic curves — source: LEM HTFS 400-P datasheet
Accuracy & Dynamic Characteristics
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %
Linearity Error (εL) (0 ... ±IPN)±0.5 %
Frequency Bandwidth (−3 dB)DC ... 240 kHz
Linearity error 0 ... 1.5 I (ε)≤ ±0.5 %
TCU Temperature coefficient of U≤ ±190 ppm/K
TCS Temperature coefficient of U≤ ±420 ppm/K
BW Frequency bandwidth (‒3 dB)DC ... 240 kHz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)≥ 2 kΩ