Your Trusted Source for Industrial Electrical Components

HX 20-P

Hall effect measuring principle

LEM | HX-Series | EN 50178 | Busbar Mount

±15 VPower Supply
±1 %Linearity Error (Max)
≥ 10 kΩLoad resistance (R)
< ±40 mVElectrical Offset Voltage (VO E) @ IP = 0, TA = 25 °C
≤ 3 µsDelay time to 90 % of the output value for I step (t)

Additional Technical Details

View Full Specifications
Supply Voltage±15 V
Accuracy @ IPN±1 %
Operating Temperature Range−25 ... +85 °C
Isolation Test Voltage3 kV
Current Consumption (IC)< ±15 mA
Output internal resistance (R)< 50 Ω

Standards & Approvals

  • EN 50178:

Typical Applications

AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Electrical appliances

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HX 20-P is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation, delivering a output internal resistance (r) of < 50 Ω.

Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error ±1 %; operating temperature −25 ... +85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHX
Product ReferenceHX 20-P
Supply Voltage±15 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainIndustrial
Electrical Data — HX 20-P
Supply Voltage (UC)±15 V
Current Consumption (IC)< ±15 mA
Output internal resistance (R)< 50 Ω
Load resistance (R)≥ 10 kΩ
Supply voltage (±5 %) (U)±15 V
Current consumption (I)< ±15 mA
Accuracy & Dynamic Performance
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %
Linearity Error (εL) (0 ... ±IPN)±1 %
Electrical Offset Voltage (VO E) @ IP = 0, TA = 25 °C< ±40 mV
Delay time to 90 % of the output value for I step (t)≤ 3 µs
BW Frequency bandwidth (−3 dB)50 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−25 ... +85 °C
Ambient Storage Temperature (TA st)−25 ... +85 °C
Mass (m)8 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm
Ambient operating temperature (T)−25 ... +85 °C
Ambient storage temperature (T)−25 ... +85 °C
Standards & Certifications
EN 50178Compliance
Standard EN 50178:1997

Note: Specifications are taken from the official HX 20-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HX 20-P are shown below.

HX 20-P outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HX 20-P datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Mass8 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HX 20-P.

AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Electrical appliances

Characteristic Curves

Characteristic curve diagrams are not included in the HX 20-P datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %
Linearity Error (εL) (0 ... ±IPN)±1 %
BW Frequency bandwidth (−3 dB)50 kHz
Reference Conditions
Ambient Temperature (TA)25 °C, unless otherwise noted
Output Load Resistance (RL)≥ 10 kΩ

Note: For the full set of performance data, refer to the datasheet.