Your Trusted Source for Industrial Electrical Components

HXS 20-NP/SP30

Hall effect measuring principle

LEM | HXS-Series | PCB Mount

5 VPower Supply
DC ... 50 kHzBandwidth (-1dB)
±0.5 %Linearity Error (Max)
3.5 kVRMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud
−40 ... +85 °CAmbient Operating Temperature (TA)

Additional Technical Details

View Full Specifications
Supply Voltage5 V
Accuracy @ IPN±1 %
Operating Temperature Range−40 ... +85 °C
Isolation Test Voltage3.5 kV
Current Consumption (IC)@ U = 5 V 19 mA
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %

Standards & Approvals

Typical Applications

Hall effect measuring principle, Multirange current transducer through PCB pattern lay-out, Galvanic separation between primary and secondary circuit, Insulation test voltage 3500 V, Extremely low profile < 11 mm, Fixed offset & sensitivity, Low power consumption, Single power supply +5 V, Insulating plastic case recognized according to UL 94-V0. Special feature, Designed to avoid heating. Advantages, Small size and space saving, Only one design for wide current ratings range, High immunity to external interference, U IN OUT. ref / Application, AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The HXS 20-NP/SP30 is a None current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

Typical applications include Hall effect measuring principle, Multirange current transducer through PCB pattern lay-out, Galvanic separation between primary and secondary circuit and Insulation test voltage 3500 V.

Key characteristics from the official datasheet: linearity error ±0.5 %; frequency bandwidth DC ... 50 kHz; operating temperature −40 ... +85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesHXS
Product ReferenceHXS 20-NP/SP30
Supply Voltage5 V
Measurementcurrents: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — HXS 20-NP/SP30
Supply Voltage (UC)5 V
Current Consumption (IC)@ U = 5 V 19 mA
Accuracy & Dynamic Performance
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %
Linearity Error (εL) (0 ... ±IPN)±0.5 %
Frequency Bandwidth (−3 dB)DC ... 50 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3.5 kV
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−40 ... +85 °C
Mass (m)10 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.2 mm

Note: Specifications are taken from the official HXS 20-NP/SP30 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the HXS 20-NP/SP30 are shown below.

HXS 20-NP/SP30 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM HXS 20-NP/SP30 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.2 mm
Mass10 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the HXS 20-NP/SP30.

Hall effect measuring principle
Multirange current transducer through PCB pattern lay-out
Galvanic separation between primary and secondary circuit
Insulation test voltage 3500 V
Extremely low profile < 11 mm
Fixed offset & sensitivity
Low power consumption

Characteristic Curves

Characteristic curve diagrams are not included in the HXS 20-NP/SP30 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Accuracy @ IPN, TA = 25 °C, ±15 V±1 %
Linearity Error (εL) (0 ... ±IPN)±0.5 %
Frequency Bandwidth (−3 dB)DC ... 50 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment