LEM | IN-Series | Closed loop (compensated) | IEC 61010-1 | Busbar Mount

−500 ... 500 ANominal Primary Current
14.25 ... 15.75 VPower Supply
Closed loop (compensated)Technology
1 µsResponse Time to 90 % of IPN Step
4.2 kVRMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−800 ... 800 A
Supply Voltage14.25 ... 15.75 V
Operating Temperature Range−40 ... 85 °C
Isolation Test Voltage4.2 kV
Primary Nominal RMS Current (IPN)−500 ... 500 A
Current Consumption (IC)0.79 A

Standards & Approvals

  • IEC 61010-1

Typical Applications

Feedback element in high performance gradient amplifiers for MRI, Feedback element in high-precision, high-stability power supplies, Calibration unit, Feedback element for Power Meter (e.g. EV Test Benches), Medical equipment. Standards IEC 61010-1 EMC:, IEC 61000-6-2: 2016, IEC 61000-6-3: 2006 + A1 (2010) Safety:, IEC 61010-2-030: 2017, IEC 61010-1:2010/AMD1: 2016. Application Domains, Industrial, Laboratory, Medical.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The IN 500-S is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

It offers low temperature drift and wide frequency bandwidth. Typical applications include Feedback element in high performance gradient amplifiers for MRI, Feedback element in high-precision, high-stability power supplies, Calibration unit and Feedback element for Power Meter (e.g. EV Test Benches).

Key characteristics from the official datasheet: operating temperature −40 ... 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesIN
Product ReferenceIN 500-S
Primary Nominal Current−500 ... 500 A
Supply Voltage14.25 ... 15.75 V
Measurementcurrent: DC, AC, pulsed...
MountingBusbar Mount
Application DomainIndustrial, Laboratory, Medical
Electrical Data — IN 500-S
Primary Nominal RMS Current (IPN)−500 ... 500 A
Primary Current, Measuring Range (IPM)−800 ... 800 A
Supply Voltage (UC)14.25 ... 15.75 V
Current Consumption (IC)0.79 A
Accuracy & Dynamic Performance
Response Time to 90 % of IPN Step1 µs
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.2 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Creepage Distance (dCp)11.9 mm
Clearance (dCI)11.5 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 85 °C
Ambient Storage Temperature (TA st)−40 ... 85 °C
Mass (m)1.3 kg
Standards & Certifications
IEC 61010-1Compliance

Note: Specifications are taken from the official IN 500-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the IN 500-S are shown below.

IN 500-S outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM IN 500-S datasheet
Outline Dimensions & Mechanical Data
Mass1.3 kg

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the IN 500-S.

Feedback element in high performance gradient amplifiers for MRI
Feedback element in high-precision, high-stability power supplies
Calibration unit
Feedback element for Power Meter (e.g. EV Test Benches)
Medical equipment
IEC 61000-6-2: 2016
IEC 61000-6-3: 2006 + A1 (2010) Safety:

Characteristic Curves

The characteristic curves of the IN 500-S from the official datasheet are shown below.

IN 500-S characteristic curves
Characteristic curves — source: LEM IN 500-S datasheet
Accuracy & Dynamic Characteristics
Response Time to 90 % of IPN Step1 µs

Note: Refer to the datasheet for the complete set of characteristic curves.