Authorized Distributor
?
Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | 0 .. ± 1050 |
| Supply Voltage | ± 24 V |
| Operating Temperature Range | - 40 .. + 75 °C |
| Current Consumption (IC) | 25 + I mA PM |
| Frequency Bandwidth (BW) | E DC .. 50 kHz |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 10 kV |
AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.
The LA 306-S/SP2 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., N, with galvanic isolation.
It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).
Key characteristics from the official datasheet: linearity error < 0.1 %; frequency bandwidth E DC .. 50 kHz; operating temperature - 40 .. + 75 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LA |
| Product Reference | LA 306-S/SP2 |
| Supply Voltage | ± 24 V |
| Measurement | currents: DC, AC, pulsed..., N |
| Mounting | Busbar Mount |
| Application Domain | Industrial |
| Electrical Data — LA 306-S/SP2 | |
|---|---|
| Primary Current, Measuring Range (IPM) | 0 .. ± 1050 |
| Supply Voltage (UC) | ± 24 V |
| Current Consumption (IC) | 25 + I mA PM |
| Accuracy & Dynamic Performance | |
|---|---|
| Linearity Error (εL) | < 0.1 % |
| Frequency Bandwidth (BW) | E DC .. 50 kHz |
| Insulation Coordination | |
|---|---|
| Impulse Withstand Voltage (1.2/50 µs) UNi | 10 kV |
| Creepage Distance (dCp) | 19 mm |
| Clearance (dCI) | 11.2 mm |
| Comparative Tracking Index (CTI) | 600 |
| Rated Insulation Voltage (basic) | 1000 V |
| Rated Insulation Voltage (reinforced) | 500 V |
| Overvoltage Category / Pollution Degree | Over voltage category OV · Pollution degree PD2 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | - 40 .. + 75 °C |
| Ambient Storage Temperature (TA st) | - 45 .. + 85 °C |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| Standards & Certifications | |
|---|---|
| EN 50178 | Compliance |
| UL 508 | Compliance |
Note: Specifications are taken from the official LA 306-S/SP2 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LA 306-S/SP2.
Outline dimensions, pin layout and connection diagrams of the LA 306-S/SP2 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LA 306-S/SP2.
Characteristic curve diagrams are not included in the LA 306-S/SP2 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Linearity Error (εL) | < 0.1 % |
| Frequency Bandwidth (BW) | E DC .. 50 kHz |
Note: For the full set of performance data, refer to the datasheet.