Your Trusted Source for Industrial Electrical Components

LAC 300-S/SP5

Closed loop (compensated) current transducer using the Hall effect

LEM | LAC-Series | Closed loop (compensated) | Busbar Mount

±24 VPower Supply
Closed loop (compensated)Technology
DC ... 50 kHzBandwidth (-1dB)
±1.0 %Total Error @ IPN
< 0.1 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 ... ±1000
Secondary Nominal Current100 mA
Supply Voltage±24 V
Operating Temperature Range−40 ... +85 °C
Isolation Test Voltage5.5 kV
Secondary Nominal RMS Current (ISN)100 mA

Standards & Approvals

Typical Applications

Single or three phases inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LAC 300-S/SP5 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phases inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±1.0 %; linearity error < 0.1 %; frequency bandwidth DC ... 50 kHz; operating temperature −40 ... +85 °C; nominal secondary output 100 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLAC
Product ReferenceLAC 300-S/SP5
Supply Voltage±24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LAC 300-S/SP5
Primary Current, Measuring Range (IPM)0 ... ±1000
Secondary Nominal RMS Current (ISN)100 mA
Turns Ratio (NP/NS)1 : 2000
Supply Voltage (UC)±24 V
Current Consumption (IC)25 + I mA Advantages
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±1.0 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 50 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud5.5 kV
Creepage Distance (dCp)21.2 mm
Clearance (dCI)11.2 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−40 ... +90 °C
Mass (m)140 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm

Note: Specifications are taken from the official LAC 300-S/SP5 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LAC 300-S/SP5 are shown below.

LAC 300-S/SP5 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LAC 300-S/SP5 datasheet
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Mass140 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LAC 300-S/SP5.

Single or three phases inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
Battery chargers. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LAC 300-S/SP5 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±1.0 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 50 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment