Your Trusted Source for Industrial Electrical Components

LDSR 0.3-TP/SP1

Closed loop (compensated)

LEM | LDSR-Series | Closed loop (compensated) | EN 61800-1 | PCB Mount

300 mANominal Primary Current
4.75 ... 5.25 VPower Supply
Closed loop (compensated)Technology
2 kHzBandwidth (-1dB)
−3 ... 3 % of IPRMLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−900 ... 900 mA
Supply Voltage4.75 ... 5.25 V
Operating Temperature Range−40 ... 105 °C
Isolation Test Voltage1.71 kV
Primary Nominal RMS Current (IPN)300 mA
Current Consumption (IC)18 ... 20.5 mA

Standards & Approvals

  • EN 61800-1
  • EN 61800-2
  • EN 61800-3
  • UL 62109-1
  • IEC 61010-1
  • UL 508

Typical Applications

Leakage current measurement in transformerless PV inverters, First human contact protection of PV arrays, Failure detection in power sources, Symmetrical fault detection, Current leakage detection in stacked DC sources, Single phase nominal current measurement up to ±35 A per wire (DC or AC).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LDSR 0.3-TP/SP1 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include Leakage current measurement in transformerless PV inverters, First human contact protection of PV arrays, Failure detection in power sources and Symmetrical fault detection.

Key characteristics from the official datasheet: linearity error −3 ... 3 % of IPRM; frequency bandwidth 2 kHz; operating temperature −40 ... 105 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLDSR
Product ReferenceLDSR 0.3-TP/SP1
Primary Nominal Current300 mA
Supply Voltage4.75 ... 5.25 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — LDSR 0.3-TP/SP1
Primary Nominal RMS Current (IPN)300 mA
Primary Current, Measuring Range (IPM)−900 ... 900 mA
Supply Voltage (UC)4.75 ... 5.25 V
Current Consumption (IC)18 ... 20.5 mA
Accuracy & Dynamic Performance
Linearity Error (εL)−3 ... 3 % of IPRM
Response Time to 90 % of IPN Step300 µs
Frequency Bandwidth2 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud1.71 kV
Impulse Withstand Voltage (1.2/50 µs) UNi4 kV
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 105 °C
Ambient Storage Temperature (TA st)−50 ... 105 °C
Mass (m)25 g
Standards & Certifications
EN 61800-1:
EN 61800-2:
EN 61800-3:
UL 62109-1:
IEC 61010-1:
UL 508.

Note: Specifications are taken from the official LDSR 0.3-TP/SP1 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LDSR 0.3-TP/SP1 are shown below.

LDSR 0.3-TP/SP1 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LDSR 0.3-TP/SP1 datasheet
Outline Dimensions & Mechanical Data
Mass25 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LDSR 0.3-TP/SP1.

Leakage current measurement in transformerless PV inverters
First human contact protection of PV arrays
Failure detection in power sources
Symmetrical fault detection
Current leakage detection in stacked DC sources
Single phase nominal current measurement up to ±35 A per wire (DC or AC)
EN 61800-1: 1997

Characteristic Curves

Characteristic curve diagrams are not included in the LDSR 0.3-TP/SP1 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Linearity Error (εL)−3 ... 3 % of IPRM
Response Time to 90 % of IPN Step300 µs
Frequency Bandwidth2 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment