Your Trusted Source for Industrial Electrical Components

LESR 50-NP/SP1

Closed loop (compensated) current transducer using the Hall effect

LEM | LESR-Series | Closed loop | IEC 61800-1 | PCB Mount

50 ANominal Primary Current
4.75 ... 5.25 VPower Supply
Closed loopTechnology
300 ... 1 kHzBandwidth (-1dB)
−0.1 ... 0.1 % of IPNLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−150 ... 150 A
Output Voltage Range0.25 ... 4.75 V
Supply Voltage4.75 ... 5.25 V
Operating Temperature Range−40 ... 105 °C
Isolation Test Voltage4.3 kV
Primary Nominal RMS Current (IPN)50 A

Standards & Approvals

  • IEC 61800-1
  • IEC 61800-2
  • IEC 61800-3
  • IEC 61800-5-1
  • IEC 62109-1
  • IEC 62477-1
  • UL 508:2013

Typical Applications

AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications, Solar inverters.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LESR 50-NP/SP1 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error −0.1 ... 0.1 % of IPN; frequency bandwidth 300 ... 1 kHz; operating temperature −40 ... 105 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLESR
Product ReferenceLESR 50-NP/SP1
Primary Nominal Current50 A
Supply Voltage4.75 ... 5.25 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — LESR 50-NP/SP1
Primary Nominal RMS Current (IPN)50 A
Primary Current, Measuring Range (IPM)−150 ... 150 A
Supply Voltage (UC)4.75 ... 5.25 V
Current Consumption (IC)18 ... 1600 mA (typ 20.5 mA)
Accuracy & Dynamic Performance
Linearity Error (εL)−0.1 ... 0.1 % of IPN
Electrical Offset Voltage (VO E) @ IP = 00.875 mV
Response Time to 90 % of IPN Step0.4 µs
Frequency Bandwidth300 ... 1 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4.3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Creepage Distance (dCp)7.55 mm
Clearance (dCI)7.55 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 105 °C
Ambient Storage Temperature (TA st)−55 ... 125 °C
Mass (m)10 g
Standards & Certifications
IEC 61800-1:
IEC 61800-2:
IEC 61800-3:
IEC 61800-5-1:
IEC 62109-1:
IEC 62477-1:
UL 5082013.

Note: Specifications are taken from the official LESR 50-NP/SP1 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LESR 50-NP/SP1 are shown below.

LESR 50-NP/SP1 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LESR 50-NP/SP1 datasheet
Outline Dimensions & Mechanical Data
Mass10 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LESR 50-NP/SP1.

AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Solar inverters

Characteristic Curves

The characteristic curves of the LESR 50-NP/SP1 from the official datasheet are shown below.

LESR 50-NP/SP1 characteristic curves
Characteristic curves — source: LEM LESR 50-NP/SP1 datasheet
Accuracy & Dynamic Characteristics
Linearity Error (εL)−0.1 ... 0.1 % of IPN
Response Time to 90 % of IPN Step0.4 µs
Frequency Bandwidth300 ... 1 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment