Your Trusted Source for Industrial Electrical Components

LF 2005-S/SP3

Closed loop (compensated) current transducer using the Hall effect

LEM | LF-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

2000 ANominal Primary Current
±15 ... 24 VPower Supply
Closed loop (compensated)Technology
DC ... 150 kHzBandwidth (-1dB)
±0.3 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 ... ±3500 A
Secondary Nominal Current400 mA
Supply Voltage±15 ... 24 V
Operating Temperature Range−40 ... +70 °C
Primary Nominal RMS Current (IPN)2000 A
Secondary Nominal RMS Current (ISN)400 mA

Standards & Approvals

  • EN 50155: 2017
  • EN 50121-3-2

Typical Applications

Single or three phase inverter, Propulsion and braking chopper, Propulsion converter, Auxiliary converter, Battery charger. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 2005-S/SP3 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverter, Propulsion and braking chopper, Propulsion converter and Auxiliary converter.

Key characteristics from the official datasheet: total error ±0.3 %; linearity error < 0.1 %; frequency bandwidth DC ... 150 kHz; operating temperature −40 ... +70 °C; nominal secondary output 400 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 2005-S/SP3
Primary Nominal Current2000 A
Supply Voltage±15 ... 24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LF 2005-S/SP3
Primary Nominal RMS Current (IPN)2000 A
Primary Current, Measuring Range (IPM)0 ... ±3500 A
Secondary Nominal RMS Current (ISN)400 mA
Turns Ratio (NP/NS)1 : 5000
Supply Voltage (UC)±15 ... 24 V
Current Consumption (IC)33 (@ ±24 V) + I mA A
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.3 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 150 kHz
Insulation Coordination
Creepage Distance (dCp)81.7 mm
Clearance (dCI)59.8 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +70 °C
Ambient Storage Temperature (TA st)−50 ... +85 °C
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±1 mm
Standards & Certifications
EN 501552017
EN 50121-3-2Compliance

Note: Specifications are taken from the official LF 2005-S/SP3 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 2005-S/SP3 are shown below.

LF 2005-S/SP3 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 2005-S/SP3 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 2005-S/SP3.

Single or three phase inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LF 2005-S/SP3 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.3 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 150 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment