Your Trusted Source for Industrial Electrical Components

LF 2005-S/SP9

Closed loop (compensated) current transducer using the Hall effect

LEM | LF-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

1000 ANominal Primary Current
±15 ... 24 VPower Supply
Closed loop (compensated)Technology
DC ... 100 kHzBandwidth (-1dB)
< 0.1 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 ... ±2000 A
Conversion Ratio (KN)1 : 5000
Secondary Nominal RMS Current (ISN)200 mA
Response Time to 90 % of IPN Step< 1 µs
Isolation Test Voltage (50 Hz, 1 min)12 kV
Operating Temperature Range−40 ... +85 °C

Standards & Approvals

  • EN 50155: 2021
  • EN 50121-3-2

Typical Applications

Single or three phase inverter, Propulsion and braking chopper, Propulsion converter, Auxiliary converter, Battery charger. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 2005-S/SP9 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., I = 1000 A, with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverter, Propulsion and braking chopper, Propulsion converter and Auxiliary converter.

Key characteristics from the official datasheet: linearity error < 0.1 %; frequency bandwidth DC ... 100 kHz; operating temperature −40 ... +85 °C; nominal secondary output 200 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 2005-S/SP9
Primary Nominal Current1000 A
Supply Voltage±15 ... 24 V
Measurementcurrents: DC, AC, pulsed..., I = 1000 A
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LF 2005-S/SP9
Primary Nominal RMS Current (IPN)1000 A
Primary Current, Measuring Range (IPM)0 ... ±2000 A
Secondary Nominal RMS Current (ISN)200 mA
Conversion Ratio (KN)1 : 5000
Supply Voltage (UC)±15 ... 24 V
Current Consumption (IC)33 (@ ±24 V) + IS mA
Turns Ratio (NP/NS)1 : 5000
Accuracy & Dynamic Performance
Linearity Error (εL)< 0.1 %
Response Time to 90 % of IPN Step (tr)< 1 µs
Frequency Bandwidth (-1 dB) (BW)DC ... 100 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud12 kV
Creepage Distance (dCp)51.5 mm
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−40 ... +85 °C
Secondary Coil Resistance @ TA = 70 °C (RS)33 Ω
Case MaterialInsulating plastic case recognized according to UL 94-V0.
Standards & Certifications
EN 501552021
EN 50121-3-2Compliance

Note: Specifications are taken from the official LF 2005-S/SP9 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 2005-S/SP9 are shown below.

LF 2005-S/SP9 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 2005-S/SP9 datasheet, page 4
Outline Dimensions & Mechanical Data
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 2005-S/SP9.

Single or three phase inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger. Application Domain
Railway (fixed installations and onboard). Page 1/4 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LF 2005-S/SP9 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Linearity Error (εL)< 0.1 %
Response Time to 90 % of IPN Step (tr)< 1 µs
Frequency Bandwidth (-1 dB) (BW)DC ... 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment