Your Trusted Source for Industrial Electrical Components

LF 2005-S

Closed loop (compensated) current transducer using the Hall effect

LEM | LF-Series | Closed loop (compensated) | EN 50178 | Busbar Mount

2000 ANominal Primary Current
± 15 .. 24 VPower Supply
Closed loop (compensated)Technology
DC .. 100 kHzBandwidth (-1dB)
± 0.3 %Overall Accuracy @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 3000 A
Conversion Ratio (KN)1 : 5000
Secondary Nominal RMS Current (ISN)400 mA
Response Time to 90 % of IPN Step< 1 µs
Isolation Test Voltage (50 Hz, 1 min)6 kV
Operating Temperature Range- 40 .. + 85 °C

Standards & Approvals

  • EN 50178

Typical Applications

AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications. Application Domain, Industrial.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 2005-S is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include AC variable speed drives and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).

Key characteristics from the official datasheet: linearity error < 0.1 %; frequency bandwidth DC .. 100 kHz; operating temperature - 40 .. + 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 2005-S
Primary Nominal Current2000 A
Supply Voltage± 15 .. 24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainIndustrial
Electrical Data — LF 2005-S
Primary Nominal RMS Current (IPN)2000 A
Primary Current, Measuring Range (IPM)0 .. ± 3000 A
Secondary Nominal RMS Current (ISN)400 mA
Conversion Ratio (KN)1 : 5000
Supply Voltage (UC)± 15 .. 24 V
Current Consumption (IC)33 (@ ± 24 V) + IS mA
Accuracy & Dynamic Performance
Overall Accuracy @ IPN, TA = 25 °C (XG)± 0.3 %
Linearity Error (εL)< 0.1 %
Temperature Variation of IO (Max)± 1.5 mA
Response Time to 90 % of IPN Step (tr)< 1 µs
di/dt Accurately Followed> 50 A/µs
Frequency Bandwidth (-1 dB) (BW)DC .. 100 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Creepage Distance (dCp)29.1 mm
Clearance (dCI)27.1 mm
Comparative Tracking Index (CTI)600
Rated Insulation Voltage (basic)4000 V
Overvoltage Category / Pollution DegreeOver voltage category OV · Pollution degree PD2
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 40 .. + 85 °C
Ambient Storage Temperature (TA st)- 50 .. + 90 °C
Secondary Coil Resistance @ TA = 70 °C (RS)25 Ω
Standards & Certifications
EN 50178Compliance

Note: Specifications are taken from the official LF 2005-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 2005-S are shown below.

LF 2005-S outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 2005-S datasheet, page 3

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 2005-S.

AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications. Application Domain
Industrial. Page 1/3 www.lem.com prior notice

Characteristic Curves

Characteristic curve diagrams are not included in the LF 2005-S datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Overall Accuracy @ IPN, TA = 25 °C (XG)± 0.3 %
Linearity Error (εL)< 0.1 %
Response Time to 90 % of IPN Step (tr)< 1 µs
di/dt Accurately Followed> 50 A/µs
Frequency Bandwidth (-1 dB) (BW)DC .. 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment