Your Trusted Source for Industrial Electrical Components

LF 2010-S/SPA0

Closed loop (compensated)

LEM | LF-Series | Closed loop (compensated) | IEC 61800-5-1 | Panel Mount

2000 ANominal Primary Current
Closed loop (compensated)Technology
150 kHzBandwidth (-1dB)
± 0.1 %Linearity Error (Max)
1 : 5000Turns Ratio (NP/NS)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 4500 A
Secondary Nominal Current0.4 A
Operating Temperature Range−40 … 85 °C
Isolation Test Voltage6 kV
Primary Nominal RMS Current (IPN)2000 A
Secondary Nominal RMS Current (ISN)0.4 A

Standards & Approvals

  • IEC 61800-5-1

Typical Applications

UNVERIFIED.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 2010-S/SPA0
Primary Nominal Current2000 A
Measurementcurrent: DC, AC, pulsed...
MountingPanel Mount
Application Domain—
Electrical Data — LF 2010-S/SPA0
Primary Nominal RMS Current (IPN)2000 A
Primary Current, Measuring Range (IPM)0 .. ± 4500 A
Secondary Nominal RMS Current (ISN)0.4 A
Turns Ratio (NP/NS)1 : 5000
Current Consumption (IC)42 mA @ ±UC = ±15 V / 48 mA @ ±UC = ±24 V
Resistance of Secondary Winding (RS)18.6 Ohm
Accuracy & Dynamic Performance
Linearity Error (εL)± 0.1 %
Electrical Offset Current (IO)± 1 A
Magnetic Offset Current (IO M)± 1 A
Frequency Bandwidth (BW)150 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Impulse Withstand Voltage (1.2/50 µs) UNi23.2 kV
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 … 85 °C
Ambient Storage Temperature (TA st)−50 … 90 °C
Mass (m)1500 g
Case MaterialV0 according to UL 94
Standards & Certifications
IEC 61800-5-1Compliance

Note: Specifications are taken from the official LF 2010-S/SPA0 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 2010-S/SPA0 are shown below.

LF 2010-S/SPA0 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 2010-S/SPA0 datasheet
Outline Dimensions & Mechanical Data
Mass1500 g
Resistance of Secondary Winding (RS)18.6 Ohm
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 2010-S/SPA0.

UNVERIFIED

Characteristic Curves

The characteristic curves of the LF 2010-S/SPA0 from the official datasheet are shown below.

LF 2010-S/SPA0 characteristic curves
Characteristic curves — source: LEM LF 2010-S/SPA0 datasheet
Accuracy & Dynamic Characteristics
Linearity Error (εL)± 0.1 %
Frequency Bandwidth (BW)150 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment