Your Trusted Source for Industrial Electrical Components

LF 2010-S

Closed loop (compensated)

LEM | LF-Series | Closed loop (compensated) | IEC 61010-1 | Panel Mount

2000 ANominal Primary Current
±14.25 .. ±25.2 VPower Supply
Closed loop (compensated)Technology
150 kHzBandwidth (-1dB)
± 0.2 % (25 … 70 … 85 °C) / ± 0.3 % (−40 … 85 °C)Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 4250 A
Secondary Nominal Current0.4 A
Supply Voltage±14.25 .. ±25.2 V
Operating Temperature Range−40 … 85 °C
Isolation Test Voltage6 kV
Primary Nominal RMS Current (IPN)2000 A

Standards & Approvals

  • IEC 61010-1: 2010
  • IEC 61800-5-1: 2007
  • IEC 62109-1: 2010
  • UL 508 : 2013

Typical Applications

Windmill inverters, Test and measurement, AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 2010-S is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include Windmill inverters, Test and measurement, AC variable speed and servo motor drives and Static converters for DC motor drives.

Key characteristics from the official datasheet: total error ± 0.2 % (25 … 70 … 85 °C) / ± 0.3 % (−40 … 85 °C); linearity error ± 0.1 %; frequency bandwidth 150 kHz; operating temperature −40 … 85 °C; nominal secondary output 0.4 A.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 2010-S
Primary Nominal Current2000 A
Supply Voltage±14.25 .. ±25.2 V
Measurementcurrent: DC, AC, pulsed...
MountingPanel Mount
Application DomainIndustrial
Electrical Data — LF 2010-S
Primary Nominal RMS Current (IPN)2000 A
Primary Current, Measuring Range (IPM)0 .. ± 4250 A
Secondary Nominal RMS Current (ISN)0.4 A
Turns Ratio (NP/NS)1 : 5000
Supply Voltage (UC)±14.25 .. ±25.2 V
Current Consumption (IC)42 mA @ ±UC = ±15 V / 48 mA @ ±UC = ±24 V
Resistance of Secondary Winding (RS)18.6 Ohm
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN± 0.2 % (25 … 70 … 85 °C) / ± 0.3 % (−40 … 85 °C)
Linearity Error (εL)± 0.1 %
Electrical Offset Current (IO)± 1 A
Magnetic Offset Current (IO M)± 1 A
Delay Time (tD)< 0.5 µs
Frequency Bandwidth (BW)150 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud6 kV
Impulse Withstand Voltage (1.2/50 µs) UNi23 kV
Creepage Distance (dCp)29.8 mm
Clearance (dCI)28.0 mm
Comparative Tracking Index (CTI)600
Rated Insulation Voltage (basic)3600 V
Rated Insulation Voltage (reinforced)1000 V
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 … 85 °C
Ambient Storage Temperature (TA st)−50 … 90 °C
Mass (m)1500 g
Case MaterialV0 according to UL 94
Standards & Certifications
IEC 61010-12010
IEC 61800-5-12007
IEC 62109-12010
UL 508: 2013

Note: Specifications are taken from the official LF 2010-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 2010-S are shown below.

LF 2010-S outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 2010-S datasheet
Outline Dimensions & Mechanical Data
Mass1500 g
Resistance of Secondary Winding (RS)18.6 Ohm
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 2010-S.

Windmill inverters
Test and measurement
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)

Characteristic Curves

The characteristic curves of the LF 2010-S from the official datasheet are shown below.

LF 2010-S characteristic curves
Characteristic curves — source: LEM LF 2010-S datasheet
Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN± 0.2 % (25 … 70 … 85 °C) / ± 0.3 % (−40 … 85 °C)
Linearity Error (εL)± 0.1 %
Frequency Bandwidth (BW)150 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment