Your Trusted Source for Industrial Electrical Components

LF 310-S/SP20

Closed loop (compensated)

LEM | LF-Series | Closed loop (compensated) | EN 50155 | Panel Mount

300 ANominal Primary Current
±11.4 .. ±21 VPower Supply
Closed loop (compensated)Technology
100 kHzBandwidth (-1dB)
± 0.2 % (25 … 85 °C) / ± 0.2 % (−40 … 85 °C)Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 500 A
Secondary Nominal Current0.15 A
Supply Voltage±11.4 .. ±21 V
Operating Temperature Range−40 … 85 °C
Isolation Test Voltage3.8 kV
Primary Nominal RMS Current (IPN)300 A

Standards & Approvals

  • EN 50155: 2021
  • EN 50124:2017
  • EN 50121-3-2: 2016
  • IEC 61010-1: 2010

Typical Applications

UNVERIFIED.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 310-S/SP20 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include UNVERIFIED.

Key characteristics from the official datasheet: total error ± 0.2 % (25 … 85 °C) / ± 0.2 % (−40 … 85 °C); linearity error ± 0.05 %; frequency bandwidth 100 kHz; operating temperature −40 … 85 °C; nominal secondary output 0.15 A.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 310-S/SP20
Primary Nominal Current300 A
Supply Voltage±11.4 .. ±21 V
Measurementcurrent: DC, AC, pulsed...
MountingPanel Mount
Application Domain—
Electrical Data — LF 310-S/SP20
Primary Nominal RMS Current (IPN)300 A
Primary Current, Measuring Range (IPM)0 .. ± 500 A
Secondary Nominal RMS Current (ISN)0.15 A
Turns Ratio (NP/NS)1 : 2000
Supply Voltage (UC)±11.4 .. ±21 V
Current Consumption (IC)33 + IS mA @ ±UC = ±12 V / 35 + IS mA @ ±UC = ±15 V / 38 + IS mA @ ±UC = ±20 V
Resistance of Secondary Winding (RS)22.5 Ohm
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN± 0.2 % (25 … 85 °C) / ± 0.2 % (−40 … 85 °C)
Linearity Error (εL)± 0.05 %
Electrical Offset Current (IO)± 0.2 A
Magnetic Offset Current (IO M)± 0.2 A
Frequency Bandwidth (BW)100 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3.8 kV
Impulse Withstand Voltage (1.2/50 µs) UNi10 kV
Creepage Distance (dCp)22.5 mm
Clearance (dCI)9.5 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 … 85 °C
Ambient Storage Temperature (TA st)−50 … 90 °C
Mass (m)107 g
Case MaterialV0 according to UL 94
Standards & Certifications
EN 501552021
EN 501242017
EN 50121-3-22016
IEC 61010-12010

Note: Specifications are taken from the official LF 310-S/SP20 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 310-S/SP20 are shown below.

LF 310-S/SP20 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 310-S/SP20 datasheet
Outline Dimensions & Mechanical Data
Mass107 g
Resistance of Secondary Winding (RS)22.5 Ohm
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 310-S/SP20.

UNVERIFIED

Characteristic Curves

The characteristic curves of the LF 310-S/SP20 from the official datasheet are shown below.

LF 310-S/SP20 characteristic curves
Characteristic curves — source: LEM LF 310-S/SP20 datasheet
Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN± 0.2 % (25 … 85 °C) / ± 0.2 % (−40 … 85 °C)
Linearity Error (εL)± 0.05 %
Frequency Bandwidth (BW)100 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment