Your Trusted Source for Industrial Electrical Components

LF 505-S/SP22

Closed loop (compensated) current transducer using the Hall effect

LEM | LF-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

500 (630/10 sec)Nominal Primary Current
1) ±15 ... 24 VPower Supply
Closed loop (compensated)Technology
DC ... 100 kHzBandwidth (-1dB)
±0.6 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range@ ±24 V 0 ..
Secondary Nominal Current143 mA
Supply Voltage1) ±15 ... 24 V
Operating Temperature Range−40 ... +70 °C
Isolation Test Voltage4 kV
Primary Nominal RMS Current (IPN)500 (630/10 sec)

Standards & Approvals

  • EN 50155

Typical Applications

Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 505-S/SP22 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±0.6 %; linearity error < 0.1 %; frequency bandwidth DC ... 100 kHz; operating temperature −40 ... +70 °C; nominal secondary output 143 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 505-S/SP22
Primary Nominal Current500 (630/10 sec)
Supply Voltage1) ±15 ... 24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LF 505-S/SP22
Primary Nominal RMS Current (IPN)500 (630/10 sec)
Primary Current, Measuring Range (IPM)@ ±24 V 0 ..
Secondary Nominal RMS Current (ISN)143 mA
Turns Ratio (NP/NS)1 : 3500
Supply Voltage (UC)1) ±15 ... 24 V
Current Consumption (IC)30 (@ ±24) + I mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.6 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 100 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud4 kV
Comparative Tracking Index (CTI)175
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +70 °C
Ambient Storage Temperature (TA st)−40 ... +85 °C
Mass (m)230 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±0.5 mm
Standards & Certifications
EN 50155Compliance

Note: Specifications are taken from the official LF 505-S/SP22 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 505-S/SP22 are shown below.

LF 505-S/SP22 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 505-S/SP22 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Mass230 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 505-S/SP22.

Single or three phase inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
Battery chargers

Characteristic Curves

Characteristic curve diagrams are not included in the LF 505-S/SP22 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.6 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment