Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | 0 ... ±800 A |
| Secondary Nominal Current | 100 mA |
| Supply Voltage | ±15 ... 24 V |
| Operating Temperature Range | −40 ... +70 °C |
| Isolation Test Voltage | 3.8 kV |
| Primary Nominal RMS Current (IPN) | 500 A |
Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers.
The LF 505-S is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.
Key characteristics from the official datasheet: total error ±0.6 %; linearity error < 0.1 %; frequency bandwidth DC ... 100 kHz; operating temperature −40 ... +70 °C; nominal secondary output 100 mA.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LF |
| Product Reference | LF 505-S |
| Primary Nominal Current | 500 A |
| Supply Voltage | ±15 ... 24 V |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | Busbar Mount |
| Application Domain | Railway (fixed installations and onboard) |
| Electrical Data — LF 505-S | |
|---|---|
| Primary Nominal RMS Current (IPN) | 500 A |
| Primary Current, Measuring Range (IPM) | 0 ... ±800 A |
| Secondary Nominal RMS Current (ISN) | 100 mA |
| Turns Ratio (NP/NS) | 1 : 5000 |
| Supply Voltage (UC) | ±15 ... 24 V |
| Current Consumption (IC) | (±1 mA) 34 (@ ±24) + I mA |
| Accuracy & Dynamic Performance | |
|---|---|
| Total Error (εtot) @ IPN | ±0.6 % |
| Linearity Error (εL) | < 0.1 % |
| Frequency Bandwidth (BW) | DC ... 100 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 3.8 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 12.5 kV |
| Creepage Distance (dCp) | 15.2 mm |
| Clearance (dCI) | 14.5 mm |
| Comparative Tracking Index (CTI) | 175 |
| Rated Insulation Voltage (basic) | 1250 V |
| Rated Insulation Voltage (reinforced) | 690 V |
| Overvoltage Category / Pollution Degree | Over voltage category OV · Pollution degree PD2 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... +70 °C |
| Ambient Storage Temperature (TA st) | −40 ... +85 °C |
| Mass (m) | 230 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| General Tolerance | ±0.5 mm |
| Standards & Certifications | |
|---|---|
| EN 50155 | Compliance |
| EN 50121-3-2 | Compliance |
Note: Specifications are taken from the official LF 505-S datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LF 505-S.
Outline dimensions, pin layout and connection diagrams of the LF 505-S are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| General Tolerance | ±0.5 mm |
| Mass | 230 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LF 505-S.
Characteristic curve diagrams are not included in the LF 505-S datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Total Error (εtot) @ IPN | ±0.6 % |
| Linearity Error (εL) | < 0.1 % |
| Frequency Bandwidth (BW) | DC ... 100 kHz |
Note: For the full set of performance data, refer to the datasheet.