Your Trusted Source for Industrial Electrical Components

LF 510-S/SP13

Closed loop (compensated)

LEM | LF-Series | Closed loop (compensated) | Panel Mount

500 ANominal Primary Current
Closed loopTechnology
±22.8 ... ±25.2 VPower Supply
200 kHz (−3 dB)Bandwidth (-3dB)
−0.5 ... 0.5 % of IPN (−10 ... 70 °C)Overall Accuracy @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range−1286 ... 1286 A
Secondary Nominal RMS Current0.1 A
Theoretical Sensitivity0.2 mA/A
Offset Current referred to primary−1 ... 1 A
Isolation Test Voltage3 kV
Operating Temperature Range−10 ... 70 °C

Standards & Approvals

Typical Applications

UNVERIFIED.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LF 510-S/SP13 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation, delivering a output rms current noise referred to primary (ino) of 50 mA (1 Hz to 20 kHz).

Typical applications include UNVERIFIED.

Key characteristics from the official datasheet: linearity error ± 0.1 %; frequency bandwidth 200 kHz; operating temperature −10 … 70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLF
Product ReferenceLF 510-S/SP13
Primary Nominal Current500 A
Supply Voltage±22.8 ... ±25.2 V
Measurementcurrent: DC, AC, pulsed...
MountingPanel Mount
Application DomainIndustrial
Electrical Data — LF 510-S/SP13
Primary Nominal RMS Current (IPN)500 A
Primary Current, Measuring Range (IPM)−1286 ... 1286 A
Measuring Resistance (RM)5 Ω (max)
Secondary Nominal RMS Current (ISN)0.1 A
Resistance of Secondary Winding (RS)52.8 Ω
Secondary Current (IS)−0.257 ... 0.257 A
Number of Secondary Turns (NS)5000
Theoretical Sensitivity (Gth)0.2 mA/A
Supply Voltage (±UC)±22.8 ... ±25.2 V
Current Consumption (IC)49 mA + IS
Accuracy & Dynamic Performance
Offset Current referred to primary (IO)−1 ... 1 A
Temperature Variation of IO (IOT)−0.6 ... 0.6 A
Magnetic Offset Current (IOM)±0.7 A (after 3 × IPN)
Sensitivity Error (εG)−0.5 ... 0.5 %
Linearity Error (εL)−0.1 ... 0.1 % of IPN
Overall Accuracy @ IPN (XG)−0.5 ... 0.5 % of IPN (−10 ... 70 °C)
Output RMS Current Noise referred to primary (Ino)50 mA (1 Hz to 20 kHz)
Reaction Time @ 10 % of IPN (tra)< 0.5 µs
Step Response Time to 90 % of IPN (tr)< 0.5 µs
Frequency Bandwidth (−3 dB)200 kHz (−3 dB)
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3 kV
Impulse Withstand Voltage (1.2/50 µs) ÛW10.8 kV
Insulation Resistance (RIS)200 MΩ (measured at 500 V DC)
Case MaterialV0 according to UL 94
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−10 ... 70 °C
Ambient Storage Temperature (TS)−25 ... 85 °C
Mass (m)240 g
Standards & Certifications
EN 501781997
UL 5082010

Note: Specifications are taken from the official LF 510-S/SP13 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LF 510-S/SP13 are shown below.

LF 510-S/SP13 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LF 510-S/SP13 datasheet
Outline Dimensions & Mechanical Data
Mass240 g
Resistance of Secondary Winding (RS)52.8 Ω
Case MaterialV0 according to UL 94

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LF 510-S/SP13.

UNVERIFIED

Characteristic Curves

The characteristic curves of the LF 510-S/SP13 from the official datasheet are shown below.

LF 510-S/SP13 characteristic curves
Characteristic curves — source: LEM LF 510-S/SP13 datasheet
Accuracy & Dynamic Characteristics
Theoretical Sensitivity (Gth)0.2 mA/A
Sensitivity Error (εG)−0.5 ... 0.5 %
Linearity Error (εL)−0.1 ... 0.1 % of IPN
Overall Accuracy @ IPN (XG)−0.5 ... 0.5 % of IPN (−10 ... 70 °C)
Step Response Time to 90 % of IPN (tr)< 0.5 µs
Frequency Bandwidth (−3 dB)200 kHz (−3 dB)

Note: Refer to the datasheet for the complete set of characteristic curves.