Authorized Distributor
?
Closed loop (compensated)
| Primary Current, Measuring Range | 0 .. ± 1500 A |
| Secondary Nominal Current | 0.1 A |
| Supply Voltage | ±14.25 .. ±25.2 V |
| Operating Temperature Range | −40 … 85 °C |
| Isolation Test Voltage | 14.5 kV |
| Primary Nominal RMS Current (IPN) | 500 A |
Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers, Substations.
The LF 510-S/SP23 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.
Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.
Key characteristics from the official datasheet: total error ± 0.5 % (25 … 70 … 85 °C) / ± 0.6 % (−40 … 85 °C); linearity error ± 0.1 %; frequency bandwidth 200 kHz; operating temperature −40 … 85 °C; nominal secondary output 0.1 A.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LF |
| Product Reference | LF 510-S/SP23 |
| Primary Nominal Current | 500 A |
| Supply Voltage | ±14.25 .. ±25.2 V |
| Measurement | current: DC, AC, pulsed... |
| Mounting | Panel Mount |
| Application Domain | — |
| Electrical Data — LF 510-S/SP23 | |
|---|---|
| Primary Nominal RMS Current (IPN) | 500 A |
| Primary Current, Measuring Range (IPM) | 0 .. ± 1500 A |
| Secondary Nominal RMS Current (ISN) | 0.1 A |
| Turns Ratio (NP/NS) | 1 : 5000 |
| Supply Voltage (UC) | ±14.25 .. ±25.2 V |
| Current Consumption (IC) | 44 mA @ ±UC = ±15 V / 49 mA @ ±UC = ±24 V |
| Resistance of Secondary Winding (RS) | 52.8 Ohm |
| Accuracy & Dynamic Performance | |
|---|---|
| Total Error (εtot) @ IPN | ± 0.5 % (25 … 70 … 85 °C) / ± 0.6 % (−40 … 85 °C) |
| Linearity Error (εL) | ± 0.1 % |
| Electrical Offset Current (IO) | ± 1 A |
| Magnetic Offset Current (IO M) | ± 0.7 A |
| Delay Time (tD) | < 0.5 µs |
| Frequency Bandwidth (BW) | 200 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 14.5 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 14.5 kV |
| Creepage Distance (dCp) | 20 mm |
| Clearance (dCI) | 20 mm |
| Comparative Tracking Index (CTI) | 600 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 … 85 °C |
| Ambient Storage Temperature (TA st) | −50 … 90 °C |
| Mass (m) | 320 g |
| Case Material | V0 according to UL 94 |
| Standards & Certifications | |
|---|---|
| EN 50155 | 2021 |
| EN 50124-1 | 2017 |
| EN 50121-3-2 | 2016 |
| IEC 62497-1 | 2010 |
| UL 508 | 2013 |
Note: Specifications are taken from the official LF 510-S/SP23 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LF 510-S/SP23.
Outline dimensions, pin layout and connection diagrams of the LF 510-S/SP23 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 320 g |
| Resistance of Secondary Winding (RS) | 52.8 Ohm |
| Case Material | V0 according to UL 94 |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LF 510-S/SP23.
The characteristic curves of the LF 510-S/SP23 from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Total Error (εtot) @ IPN | ± 0.5 % (25 … 70 … 85 °C) / ± 0.6 % (−40 … 85 °C) |
| Linearity Error (εL) | ± 0.1 % |
| Frequency Bandwidth (BW) | 200 kHz |
Note: Refer to the datasheet for the complete set of characteristic curves.