LT 1005-S/SP4

Closed loop (compensated) current transducer using the Hall effect

LEM | LT-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

1000 ANominal Primary Current
± 15 .. 24 VPower Supply
Closed loop (compensated)Technology
DC .. 150 kHzBandwidth (-1dB)
± 0.4 %Overall Accuracy @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 2000 A
Conversion Ratio (KN)1 : 4000
Secondary Nominal RMS Current (ISN)250 mA
Response Time to 90 % of IPN Step< 1 µs
Impulse Withstand Voltage (1.2/50 µs)38 kV
Operating Temperature Range- 40 .. + 85 °C

Standards & Approvals

  • EN 50155

Typical Applications

Single or three phase inverters, Propulsion and braking chopper, Propulsion converter, Auxiliary converter, Battery charger. Application Domain, Traction.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LT 1005-S/SP4 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking chopper, Propulsion converter and Auxiliary converter.

Key characteristics from the official datasheet: linearity error < 0.1 %; frequency bandwidth DC .. 150 kHz; operating temperature - 40 .. + 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLT
Product ReferenceLT 1005-S/SP4
Primary Nominal Current1000 A
Supply Voltage± 15 .. 24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainTraction
Electrical Data — LT 1005-S/SP4
Primary Nominal RMS Current (IPN)1000 A
Primary Current, Measuring Range (IPM)0 .. ± 2000 A
Secondary Nominal RMS Current (ISN)250 mA
Conversion Ratio (KN)1 : 4000
Supply Voltage (UC)± 15 .. 24 V
Current Consumption (IC)30 (@ ± 24 V) + IS mA
Accuracy & Dynamic Performance
Overall Accuracy @ IPN, TA = 25 °C (XG)± 0.4 %
Linearity Error (εL)< 0.1 %
Offset Current @ IP = 0, TA = 25 °C (IO)± 0.50 mA
Temperature Variation of IO (Max)± 0.80 mA
Response Time to 90 % of IPN Step (tr)< 1 µs
di/dt Accurately Followed> 50 A/µs
Frequency Bandwidth (-1 dB) (BW)DC .. 150 kHz
Insulation Coordination
Impulse Withstand Voltage (1.2/50 µs) UNi38 kV
Creepage Distance (dCp)61.9 mm
Clearance (dCI)53.1 mm
Comparative Tracking Index (CTI)225
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 40 .. + 85 °C
Ambient Storage Temperature (TA st)- 50 .. + 95 °C
Secondary Coil Resistance @ TA = 70 °C (RS)26 Ω
Mass (m)850 g
Standards & Certifications
EN 50155Compliance

Note: Specifications are taken from the official LT 1005-S/SP4 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LT 1005-S/SP4 are shown below.

LT 1005-S/SP4 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LT 1005-S/SP4 datasheet, page 3
Outline Dimensions & Mechanical Data
Mass850 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LT 1005-S/SP4.

Single or three phase inverters
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger. Application Domain
Traction. Page 1/3 without prior notice www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LT 1005-S/SP4 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Overall Accuracy @ IPN, TA = 25 °C (XG)± 0.4 %
Linearity Error (εL)< 0.1 %
Response Time to 90 % of IPN Step (tr)< 1 µs
di/dt Accurately Followed> 50 A/µs
Frequency Bandwidth (-1 dB) (BW)DC .. 150 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination