LT 4000-S/SP24

Closed loop (compensated)

LEM | LT-Series | Closed loop (compensated) | Panel Mount

±22.8 ... ±25.2 VPower Supply
Closed loop (compensated)Technology
DC .. 100 kHzBandwidth (-1dB)
3300 APrimary Nominal RMS Current (IPN)
25 ... 29 mACurrent Consumption (IC)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range0 .. ± 5000 A
Conversion Ratio (KN)1 : 5000
Secondary Nominal RMS Current (ISN)660 mA
Response Time to 90 % of IPN Step< 1 µs
Operating Temperature Range- 25 .. + 70 °C
di/dt Accurately Followed> 50 A/µs

Standards & Approvals

Typical Applications

Single or three phase inverters, Propulsion and braking choppers, l o Prs ope ud nl o coo nvp te( rscompensated) current lsio er, A nu sxil diar uy cco env re rt uer ss, High power drives, sSuublsatatteionds. plastic case recognized aSctcanodradrding to UL 94-V0, EN 50155: 2021. Application Domain features, Railway (fixed installations and onboard). between primary and Connection to secondary circuit on LEMO EGJ. 1B. 304. CYC.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LT 4000-S/SP24 is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, L o Prs ope ud nl o coo nvp te( rscompensated) current lsio er and A nu sxil diar uy cco env re rt uer ss.

Key characteristics from the official datasheet: linearity error 0.2 % of IPN; operating temperature −25 ... 70 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLT
Product ReferenceLT 4000-S/SP24
Supply Voltage±22.8 ... ±25.2 V
Measurementcurrent: DC, AC, pulsed...
MountingPanel Mount
Application DomainRailway (fixed installations and onboard). between primary and to secondary circuit on EGJ. 1B. 304
Electrical Data — LT 4000-S/SP24
Primary Nominal RMS Current (IPN)3300 A
Primary Current, Measuring Range (IPM)0 .. ± 5000 A
Secondary Nominal RMS Current (ISN)660 mA
Conversion Ratio (KN)1 : 5000
Supply Voltage (UC)±22.8 ... ±25.2 V
Current Consumption (IC)25 ... 29 mA
Accuracy & Dynamic Performance
Linearity Error (εL)0.2 % of IPN
Offset Current @ IP = 0, TA = 25 °C (IO)± 0.8 mA
Temperature Variation of IO (Max)± 0.8 mA
Response Time to 90 % of IPN Step (tr)< 1 µs
di/dt Accurately Followed> 50 A/µs
Frequency Bandwidth (-1 dB) (BW)DC .. 100 kHz
Insulation Coordination
Impulse Withstand Voltage (1.2/50 µs) UNi17.7 kV
Creepage Distance (dCp)75.8 mm
Clearance (dCI)69.8 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)- 25 .. + 70 °C
Ambient Storage Temperature (TA st)- 40 .. + 85 °C
Secondary Coil Resistance @ TA = 70 °C (RS)15 Ω
Mass (m)6000 g

Note: Specifications are taken from the official LT 4000-S/SP24 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LT 4000-S/SP24 are shown below.

LT 4000-S/SP24 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LT 4000-S/SP24 datasheet
Outline Dimensions & Mechanical Data
Mass6000 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LT 4000-S/SP24.

Single or three phase inverters
Propulsion and braking choppers
L o Prs ope ud nl o coo nvp te( rscompensated) current lsio er
A nu sxil diar uy cco env re rt uer ss
High power drives
SSuublsatatteionds. plastic case recognized aSctcanodradrding to UL 94-V0
EN 50155: 2021. Application Domain features

Characteristic Curves

The characteristic curves of the LT 4000-S/SP24 from the official datasheet are shown below.

LT 4000-S/SP24 characteristic curves
Characteristic curves — source: LEM LT 4000-S/SP24 datasheet
Accuracy & Dynamic Characteristics
Linearity Error (εL)0.2 % of IPN
Response Time to 90 % of IPN Step (tr)< 1 µs
di/dt Accurately Followed> 50 A/µs
Frequency Bandwidth (-1 dB) (BW)DC .. 100 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment