Your Trusted Source for Industrial Electrical Components

LTC 1000-S/SP28

Closed loop (compensated) current transducer using the Hall effect

LEM | LTC-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

1000 ANominal Primary Current
±15 ... 24 VPower Supply
Closed loop (compensated)Technology
DC ... 100 kHzBandwidth (-1dB)
± 0.4 %Overall Accuracy @ IPN

Additional Technical Details

View Full Specifications
Conversion Ratio (KN)1 : 5000
Secondary Nominal RMS Current (ISN)200 mA
Response Time to 90 % of IPN Step< 1 µs
Isolation Test Voltage (50 Hz, 1 min)13.4 kV
Operating Temperature Range−40 ... +85 °C
Secondary Coil Resistance @ 85 °C44 Ω

Standards & Approvals

  • EN 50155: 20173)

Typical Applications

Single or three phase inverter, Propulsion and braking chopper, Propulsion converter, Auxiliary converter, Battery charger. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LTC 1000-S/SP28 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverter, Propulsion and braking chopper, Propulsion converter and Auxiliary converter.

Key characteristics from the official datasheet: total error ±0.4 %; linearity error < 0.1 %; frequency bandwidth DC ... 100 kHz; operating temperature −40 ... +85 °C; nominal secondary output 200 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLTC
Product ReferenceLTC 1000-S/SP28
Primary Nominal Current1000 A
Supply Voltage±15 ... 24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LTC 1000-S/SP28
Primary Nominal RMS Current (IPN)1000 A
Primary Current, Measuring Range (IPM)@ ±24 V 0I
Secondary Nominal RMS Current (ISN)200 mA
Conversion Ratio (KN)1 : 5000
Supply Voltage (UC)±15 ... 24 V
Current Consumption (IC)32 (@ ±24 V) + IS mA
Turns Ratio (NP/NS)1 : 5000
Accuracy & Dynamic Performance
Overall Accuracy @ IPN, TA = 25 °C (XG)± 0.4 %
Linearity Error (εL)< 0.1 %
Offset Current @ IP = 0, TA = 25 °C (IO)± 0.5 mA
Temperature Variation of IO (Max)± 1 mA
Response Time to 90 % of IPN Step (tr)< 1 µs
Frequency Bandwidth (-1 dB) (BW)DC ... 100 kHz
Total Error (εtot) @ IPN±0.4 %
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud13.4 kV
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−45 ... +90 °C
Secondary Coil Resistance @ TA = 85 °C (RS)44 Ω
Mass (m)785 g
General Tolerance±1 mm
Standards & Certifications
EN 5015520173)

Note: Specifications are taken from the official LTC 1000-S/SP28 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LTC 1000-S/SP28 are shown below.

LTC 1000-S/SP28 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LTC 1000-S/SP28 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass785 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LTC 1000-S/SP28.

Single or three phase inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LTC 1000-S/SP28 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Overall Accuracy @ IPN, TA = 25 °C (XG)± 0.4 %
Linearity Error (εL)< 0.1 %
Response Time to 90 % of IPN Step (tr)< 1 µs
Frequency Bandwidth (-1 dB) (BW)DC ... 100 kHz
Total Error (εtot) @ IPN±0.4 %

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment