Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | @ ±24 V 0 .. |
| Supply Voltage | ±15 ... 24 V |
| Operating Temperature Range | −40 ... +70 °C |
| Turns Ratio (NP/NS) | 1 : 4000 |
| Current Consumption (IC) | < 33 (@ ±24 V) + I mA A |
| Frequency Bandwidth (BW) | DC ... 100 kHz |
Single or three phase inverters, Propulsion and braking chopper, Propulsion converter, Auxiliary converter, Battery charger.
The LTC 1000-SF/SP26 is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.
It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking chopper, Propulsion converter and Auxiliary converter.
Key characteristics from the official datasheet: total error ±0.8 %; linearity error < 0.1 %; frequency bandwidth DC ... 100 kHz; operating temperature −40 ... +70 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LTC |
| Product Reference | LTC 1000-SF/SP26 |
| Supply Voltage | ±15 ... 24 V |
| Measurement | currents: DC, AC, pulsed... |
| Mounting | Busbar Mount |
| Application Domain | Railway |
| Electrical Data — LTC 1000-SF/SP26 | |
|---|---|
| Primary Current, Measuring Range (IPM) | @ ±24 V 0 .. |
| Turns Ratio (NP/NS) | 1 : 4000 |
| Supply Voltage (UC) | ±15 ... 24 V |
| Current Consumption (IC) | < 33 (@ ±24 V) + I mA A |
| Accuracy & Dynamic Performance | |
|---|---|
| Total Error (εtot) @ IPN | ±0.8 % |
| Linearity Error (εL) | < 0.1 % |
| Frequency Bandwidth (BW) | DC ... 100 kHz |
| Insulation Coordination | |
|---|---|
| Impulse Withstand Voltage (1.2/50 µs) UNi | 8 kV |
| Creepage Distance (dCp) | 66.7 mm |
| Clearance (dCI) | 45.9 mm |
| Comparative Tracking Index (CTI) | 600 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... +70 °C |
| Ambient Storage Temperature (TA st) | −50 ... +85 °C |
| Mass (m) | 825 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
| General Tolerance | ±1 mm |
| Standards & Certifications | |
|---|---|
| EN 50155 | 2021 |
Note: Specifications are taken from the official LTC 1000-SF/SP26 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LTC 1000-SF/SP26.
Outline dimensions, pin layout and connection diagrams of the LTC 1000-SF/SP26 are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| General Tolerance | ±1 mm |
| Mass | 825 g |
| Case Material | Insulating plastic case recognized according to UL 94-V0. |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LTC 1000-SF/SP26.
Characteristic curve diagrams are not included in the LTC 1000-SF/SP26 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Total Error (εtot) @ IPN | ±0.8 % |
| Linearity Error (εL) | < 0.1 % |
| Frequency Bandwidth (BW) | DC ... 100 kHz |
Note: For the full set of performance data, refer to the datasheet.