Your Trusted Source for Industrial Electrical Components

LTC 1000-T

Closed loop (compensated) current transducer using the Hall effect

LEM | LTC-Series | Closed loop (compensated) | EN 50155 | Busbar Mount

1000 ANominal Primary Current
±15 ... 24 VPower Supply
Closed loop (compensated)Technology
DC ... 100 kHzBandwidth (-1dB)
±0.4 %Total Error @ IPN

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range@ ±24 V 0 ...
Secondary Nominal Current200 mA
Supply Voltage±15 ... 24 V
Operating Temperature Range−40 ... +85 °C
Primary Nominal RMS Current (IPN)1000 A
Secondary Nominal RMS Current (ISN)200 mA

Standards & Approvals

  • EN 50155: 2017
  • UL 508
  • EN 50121-3-2

Typical Applications

Single or three phase inverters, Propulsion and braking choppers, Propulsion converters, Auxiliary converters, Battery chargers. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LTC 1000-T is a closed loop (compensated) current transducer from LEM for the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Propulsion and braking choppers, Propulsion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±0.4 %; linearity error < 0.1 %; frequency bandwidth DC ... 100 kHz; operating temperature −40 ... +85 °C; nominal secondary output 200 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLTC
Product ReferenceLTC 1000-T
Primary Nominal Current1000 A
Supply Voltage±15 ... 24 V
Measurementcurrents: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LTC 1000-T
Primary Nominal RMS Current (IPN)1000 A
Primary Current, Measuring Range (IPM)@ ±24 V 0 ...
Secondary Nominal RMS Current (ISN)200 mA
Turns Ratio (NP/NS)1 : 5000
Supply Voltage (UC)±15 ... 24 V
Current Consumption (IC)< 32 (@ ±24 V) + I mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.4 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 100 kHz
Insulation Coordination
Creepage Distance (dCp)83.2 mm
Clearance (dCI)54.4 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... +85 °C
Ambient Storage Temperature (TA st)−45 ... +90 °C
Mass (m)1270 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.
General Tolerance±1 mm
Standards & Certifications
EN 501552017
UL 508Compliance
EN 50121-3-2Compliance

Note: Specifications are taken from the official LTC 1000-T datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LTC 1000-T are shown below.

LTC 1000-T outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LTC 1000-T datasheet
Outline Dimensions & Mechanical Data
General Tolerance±1 mm
Mass1270 g
Case MaterialInsulating plastic case recognized according to UL 94-V0.

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LTC 1000-T.

Single or three phase inverters
Propulsion and braking choppers
Propulsion converters
Auxiliary converters
Battery chargers. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Chemin des Aulx 8 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LTC 1000-T datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.4 %
Linearity Error (εL)< 0.1 %
Frequency Bandwidth (BW)DC ... 100 kHz

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment