Your Trusted Source for Industrial Electrical Components
Home Products LEM Voltage Sensors LV100 Series LV 100-1000/SP13

LV 100-1000/SP13

Closed loop (compensated) voltage transducer using the Hall effect

LEM | LV-Series | Closed loop (compensated) | 1) EN 50155 | Busbar Mount

10 mANominal Primary Current
±16 ... 33 VPower Supply
Closed loop (compensated)Technology
±0.9 %Total Error @ IPN
< 0.1 %Linearity Error (Max)

Additional Technical Details

View Full Specifications
Secondary Nominal Current50 mA
Supply Voltage±16 ... 33 V
Operating Temperature Range−25 … +70 °C
Isolation Test Voltage12 kV
Primary Nominal RMS Current (IPN)10 mA
Secondary Nominal RMS Current (ISN)50 mA

Standards & Approvals

  • 1) EN 50155

Typical Applications

Single or three phase inverters, Proplusion and braking choppers, Proplusion converters, Auxiliary converters, Battery chargers. Application Domain, Railway (fixed installations and onboard).

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LV 100-1000/SP13 is a closed loop (compensated) current transducer from LEM for the electronic measurement of voltages: DC, AC, pulsed..., with galvanic isolation.

It offers excellent accuracy, very good linearity, low temperature drift and wide frequency bandwidth. Typical applications include Single or three phase inverters, Proplusion and braking choppers, Proplusion converters and Auxiliary converters.

Key characteristics from the official datasheet: total error ±0.9 %; linearity error < 0.1 %; operating temperature −25 … +70 °C; nominal secondary output 50 mA.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLV
Product ReferenceLV 100-1000/SP13
Primary Nominal Current10 mA
Supply Voltage±16 ... 33 V
Measurementvoltages: DC, AC, pulsed...
MountingBusbar Mount
Application DomainRailway (fixed installations and onboard)
Electrical Data — LV 100-1000/SP13
Primary Nominal RMS Current (IPN)10 mA
Secondary Nominal RMS Current (ISN)50 mA
Turns Ratio (NP/NS)10000 : 2000
Supply Voltage (UC)±16 ... 33 V
Current Consumption (IC)< 32 ( @ ±33 V) + I mA
Accuracy & Dynamic Performance
Total Error (εtot) @ IPN±0.9 %
Linearity Error (εL)< 0.1 %
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud12 kV
Creepage Distance (dCp)164.8 mm
Clearance (dCI)47.1 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−25 … +70 °C
Ambient Storage Temperature (TA st)−40 … +85 °C
Mass (m)790 g
Case MaterialInsulating plastic case recognized according to UL 94-V0
General Tolerance±0.5 mm
Standards & Certifications
1) EN 50155:

Note: Specifications are taken from the official LV 100-1000/SP13 datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LV 100-1000/SP13 are shown below.

LV 100-1000/SP13 outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LV 100-1000/SP13 datasheet, page 3
Outline Dimensions & Mechanical Data
General Tolerance±0.5 mm
Mass790 g
Case MaterialInsulating plastic case recognized according to UL 94-V0

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LV 100-1000/SP13.

Single or three phase inverters
Proplusion and braking choppers
Proplusion converters
Auxiliary converters
Battery chargers. Application Domain
Railway (fixed installations and onboard). Page 1/3 LEM International SA Route du Nant-d’Avril, 152 www.lem.com

Characteristic Curves

Characteristic curve diagrams are not included in the LV 100-1000/SP13 datasheet; the relevant characteristics are the accuracy and dynamic performance data listed below.

Accuracy & Dynamic Characteristics
Total Error (εtot) @ IPN±0.9 %
Linearity Error (εL)< 0.1 %

Note: For the full set of performance data, refer to the datasheet.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment