Authorized Distributor
?
Closed loop (compensated) current transducer using the Hall effect
| Primary Current, Measuring Range | −20 ... 20 A |
| Output Voltage Range | 0.25 ... 4.75 V |
| Supply Voltage | 4.75 ... 5.25 V |
| Accuracy @ IPN | 0.45 % of IPN |
| Operating Temperature Range | −40 ... 105 °C |
| Isolation Test Voltage | 4.3 kV |
AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), Power supplies for welding applications, Solar inverters.
The LXS 6-NPS is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.
Typical applications include AC variable speed and servo motor drives, Static converters for DC motor drives, Battery supplied applications and Uninterruptible Power Supplies (UPS).
Key characteristics from the official datasheet: linearity error −0.1 ... 0.1 % of IPN; frequency bandwidth 300 ... 1 kHz; operating temperature −40 ... 105 °C.
| General Information | |
|---|---|
| Manufacturer | LEM |
| Product Series | LXS |
| Product Reference | LXS 6-NPS |
| Primary Nominal Current | 6 A |
| Supply Voltage | 4.75 ... 5.25 V |
| Measurement | current: DC, AC, pulsed... |
| Mounting | PCB Mount |
| Application Domain | Industrial |
| Electrical Data — LXS 6-NPS | |
|---|---|
| Primary Nominal RMS Current (IPN) | 6 A |
| Primary Current, Measuring Range (IPM) | −20 ... 20 A |
| Supply Voltage (UC) | 4.75 ... 5.25 V |
| Current Consumption (IC) | 18 ... 2000 mA (typ 20.5 mA) |
| Accuracy & Dynamic Performance | |
|---|---|
| Accuracy @ IPN | 0.45 % of IPN |
| Linearity Error (εL) | −0.1 ... 0.1 % of IPN |
| Electrical Offset Voltage (VO E) @ IP = 0 | −19.8 ... 19.8 mV |
| Response Time to 90 % of IPN Step | 0.4 µs |
| Frequency Bandwidth | 300 ... 1 kHz |
| Insulation Coordination | |
|---|---|
| RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud | 4.3 kV |
| Impulse Withstand Voltage (1.2/50 µs) UNi | 8 kV |
| Creepage Distance (dCp) | 7.7 mm |
| Clearance (dCI) | 7.7 mm |
| Comparative Tracking Index (CTI) | 600 |
| Environmental & Mechanical Characteristics | |
|---|---|
| Ambient Operating Temperature (TA) | −40 ... 105 °C |
| Ambient Storage Temperature (TA st) | −55 ... 125 °C |
| Mass (m) | 10 g |
| Standards & Certifications | |
|---|---|
| IEC 61800 | -1: |
| IEC 61800 | -2: |
| IEC 61800 | -3: |
| IEC 61800 | -5-1: |
| IEC 62109 | -1: |
| IEC 62477 | -1: |
| UL 508 | 2013. |
Note: Specifications are taken from the official LXS 6-NPS datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.
Official technical documentation for the LXS 6-NPS.
Outline dimensions, pin layout and connection diagrams of the LXS 6-NPS are shown below.
| Outline Dimensions & Mechanical Data | |
|---|---|
| Mass | 10 g |
Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.
Typical applications of the LXS 6-NPS.
The characteristic curves of the LXS 6-NPS from the official datasheet are shown below.
| Accuracy & Dynamic Characteristics | |
|---|---|
| Accuracy @ IPN | 0.45 % of IPN |
| Linearity Error (εL) | −0.1 ... 0.1 % of IPN |
| Response Time to 90 % of IPN Step | 0.4 µs |
| Frequency Bandwidth | 300 ... 1 kHz |