Your Trusted Source for Industrial Electrical Components

LZSR 150-P

Closed loop (compensated) current transducer using the Hall effect

LEM | LZSR-Series | Closed loop | IEC 61800-3 | PCB Mount

150 ANominal Primary Current
4.75 ... 5.25 VPower Supply
Closed loopTechnology
200 kHzBandwidth (-1dB)
−0.1 ... 0.1 % of IPNLinearity Error (Max)

Additional Technical Details

View Full Specifications
Primary Current, Measuring Range270 A
Output Voltage Range0.25 ... 4.75 V
Supply Voltage4.75 ... 5.25 V
Accuracy @ IPN0.83 % of IPN
Operating Temperature Range−40 ... 85 °C
Isolation Test Voltage3 kV

Standards & Approvals

  • IEC 61800-3
  • IEC 61800-5-1
  • IEC 62109-1
  • IEC 62477-1
  • UL 508: 2018

Typical Applications

IEC 61800-3: 2017, IEC 61800-5-1: 2007, IEC 62109-1: 2010, IEC 62477-1: 2012, UL 508: 2018. Application Domain, Industrial.

We respond to RFQs within 12 hours.
0 / 500

Sample requests are subject to manual review.

Why Buy from SafeCirk?

Authorized DistributorLEM & Bussmann
12+ Years of ExperienceIndustrial component supply
Technical SupportProduct selection & applications
Reliable SupplyLead-time & delivery support

Product Description

The LZSR 150-P is a closed loop (compensated) current transducer from LEM for the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation.

Typical applications include IEC 61800-3: 2017, IEC 61800-5-1: 2007, IEC 62109-1: 2010 and IEC 62477-1: 2012.

Key characteristics from the official datasheet: linearity error −0.1 ... 0.1 % of IPN; frequency bandwidth 200 kHz; operating temperature −40 ... 85 °C.

Technical Specifications

General Information
ManufacturerLEM
Product SeriesLZSR
Product ReferenceLZSR 150-P
Primary Nominal Current150 A
Supply Voltage4.75 ... 5.25 V
Measurementcurrent: DC, AC, pulsed...
MountingPCB Mount
Application DomainIndustrial
Electrical Data — LZSR 150-P
Primary Nominal RMS Current (IPN)150 A
Primary Current, Measuring Range (IPM)270 A
Supply Voltage (UC)4.75 ... 5.25 V
Current Consumption (IC)18 ... 20 mA
Accuracy & Dynamic Performance
Accuracy @ IPN0.83 % of IPN
Linearity Error (εL)−0.1 ... 0.1 % of IPN
Electrical Offset Voltage (VO E) @ IP = 0−2.5 ... 2.5 mV
Frequency Bandwidth200 kHz
Insulation Coordination
RMS Voltage for AC Insulation Test (50 Hz, 1 min) Ud3 kV
Impulse Withstand Voltage (1.2/50 µs) UNi8 kV
Creepage Distance (dCp)12.9 mm
Clearance (dCI)12.9 mm
Comparative Tracking Index (CTI)600
Environmental & Mechanical Characteristics
Ambient Operating Temperature (TA)−40 ... 85 °C
Ambient Storage Temperature (TA st)−55 ... 125 °C
Mass (m)44 g
Standards & Certifications
IEC 61800-3Compliance
IEC 61800-5-1Compliance
IEC 62109-1Compliance
IEC 62477-1Compliance
UL 5082018.

Note: Specifications are taken from the official LZSR 150-P datasheet. Parameters that could not be confirmed from the datasheet are marked UNVERIFIED.

Dimensions & Drawings

Outline dimensions, pin layout and connection diagrams of the LZSR 150-P are shown below.

LZSR 150-P outline dimensions and pin layout
Outline dimensions (in mm) and connection diagrams — source: LEM LZSR 150-P datasheet
Outline Dimensions & Mechanical Data
Mass44 g

Note: All dimensions are in millimetres. Refer to the official datasheet for the complete dimension drawing.

Typical Applications

Typical applications of the LZSR 150-P.

IEC 61800-3: 2017
IEC 61800-5-1: 2007
IEC 62109-1: 2010
IEC 62477-1: 2012
UL 508: 2018. Application Domain
Industrial. Page 1/13 Chemin des Aulx 8 notice www.lem.com

Characteristic Curves

The characteristic curves of the LZSR 150-P from the official datasheet are shown below.

LZSR 150-P characteristic curves
Characteristic curves — source: LEM LZSR 150-P datasheet
Accuracy & Dynamic Characteristics
Accuracy @ IPN0.83 % of IPN
Linearity Error (εL)−0.1 ... 0.1 % of IPN
Frequency Bandwidth200 kHz

Note: Refer to the datasheet for the complete set of characteristic curves.

12-Hour RFQ ResponseTimely quotation assistance
Documentation SupportDatasheets & traceability records
Worldwide DeliveryInternational logistics coordination
Order Follow-UpUpdates on lead times & shipment